Basic Accuracy Specifications |
Accuracy specifications are show as +/- (% of reading + number of digits) |
DC voltage |
Range 0.1 mV to 1000 V
Accuracy ±0.05 % + 1 |
AC voltage |
Range: 0.1 mV to 1000 V
Accuracy: ±0.7 % +4 |
DC current |
Range: 0.1 ±A to 10 A
Accuracy: ±0.2 % + 4 |
AC current |
Range: 0.1 ±A to 10 A
Accuracy: ±1.0 % + 2 |
Resistance |
Range: Range: 0.1 O to 50 MO
Accuracy ±(0.2 % + 1) |
Conductance |
Range: 60.00 nS
Accuracy: ± (1.0 % + 10) |
Diode Test |
Range: 2.0 V
Accuracy: ± (2.0 % + 1) |
Duty Cycle |
Range: 0.0 % to 99.9 %
Accuracy: Within ±(0.2 % per kHz + 0.1 %) for rise times <1 ±s |
Display counts |
6000 counts/19,999 counts in high-resolution mode |
Capacitance |
Range: 10 nF to 9999 ±F
Accuracy: ± (1.0 % + 2) |
Frequency |
Range: 0.5 Hz to 199.99 kHz
Accuracy: ± (0.005 % + 1) |
Temperature |
Range: -200 °C to +1090 °C (-328 ±F to +1994 ±F)
Accuracy: ± (1.0 % + 10) °C [± (1.0 % + 10) ±F] |
Peak Capture |
Record transients up to 250 us |
Min/Max/Avg Recording |
Display signals up to approximately 100 ms |
Safety Specifications |
Safety certifications |
ATEX |
II 2 G Ex ia IIC T4 Gb
II 2 D Ex ia IIIC T130 °C Db
I M1 Ex ia I Ma |
NEC-500 |
Class I, Div 1, Groups A-D, 130 °C |
IEXEx |
Ex ia IIC T4 Gb
Ex ia IIIC T130 °C Db
Ex ia I Ma |
GOST R Ex (Pending) |
Overvoltage protection: Measurement Category III, 1000V, Pollution Degree 2
Measurement Category IV, 600V, Pollution Degree 2
IP rating: IP67 |
General Specifications |
Power |
Three AAA batteries
Battery life: 400 hours |
Display |
LCD, with backlight |
External protection |
Rubber holster |
Warranty |
Three years |
Size with holster (HxWxL) |
6.35 cm x 10.0 cm x 19.81 cm
(2.5 in x 3.93 in x 7.8 in) |
Weight with holster |
698.5 g (1.54 lb) |