Electrical Specifications |
Operating Range |
1mA to 1200A |
Operating Range |
RangeVal |
1000mV/A, 100mV/A, 10mV/A, 1mV/A |
Current Range |
1V at 1A; 1mA to 1A, 1V at 10A; 10mA to 10A, 1V at 100A; 100mA to 100A, 1V at 1000A; 1A to 1000A |
Frequency Range |
30Hz to 3000Hz; current derating using the formula: (1000A * 1 ) / (2 * F (in kHz)) |
Common Mode Voltage |
600VAC |
Current Overload |
1200A for 5 min |
Current Overload |
Range Value |
1mV / 1m A, 1mV / 10mA (10A), 1mV / 100mA (100A), 1mV / 1A (1000A) |
Overload |
1.2A rms continuous, 12A rms continuous, 120A rms continuous, 1200A rms for 5 min |
Load Impedance |
100kW min |
Open Secondary Voltage |
< 25V by limiting circuit |
Reference Conditions |
23°C ±3°K, 20 to 75% RH, 45 to 1kHz, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered, 1MW/47 pF load, conductor centered |
Working Voltage |
600V, Cat. III |
Influence of Adjacent Conductor |
Influence of Adjacent Conductor |
< 1mA / AAC |
Influence of Conductor Position |
Influence of Conductor Position |
0.1% of Reading @ 50/60Hz |
Influence of Frequency |
Range Value |
30 to 48Hz, 65 to 1000Hz, 1 to 5kHz |
Influence of Frequency |
< 1% of Reading, < 0.5% of Reading, < 1% of Reading |
Influence of Humidity |
Influence of Humidity |
10 to 85%: £0.1% |
Output Signal |
Output Signal |
mV output (1000mV max) |
Accuracy |
Current Range |
1mV / 10mA (10A), 1mV / 100mA (100A), 1mV / 1A (1000A), 1mV / 1m A |
Accuracy |
Per IEC 185: Class 0.5 (5VA) from 48 to 65Hz |
Mechanical Specifications |
Altitude |
Operating: 0 to 2000m; Non-operating: 0 to 12km |
Colors |
Dark gray handles with red jaws |
Dimensions |
4.37 x 8.50 x 1.77" (111 x 216 x 45mm) |
Drop Test |
1m (IEC 68-2-32) |
Jaw Opening |
2.25" (57mm) max |
Material |
Handles: Polycarbonate +ABS Gray: UL 94 V0; Jaws: Polycarbonate, Red: UL 94 V0 |
Maximum Bus Bar Size |
1.95 x 0.19" (50 x 5mm) |
Maximum Cable Diameter |
2.05" (52mm) |
Mechanical Shock |
100g (IEC 68-2-27) |
Operating Temperature |
-14° to 122°F (-10° to 50°C) |
Operating Relative Humidity |
0 to 85% @ 35°C |
Output |
5 ft (1.5m) lead with 4mm safety banana plug |
Protection Index (IP) |
IP 40 (IEC 529) |
Impact Test |
IK04 0.5 J EN50102 |
Storage Temperature |
-4° to 158°F (-20° to 70°C) |
Vibration |
Test per IEC 68-2-6 |
Vibration |
Range Value |
5 to 15Hz, 15 to 25Hz, 25 to 55Hz |
Vibration |
Amplitude: 0.15 mm per IEC 68-2-6, Amplitude: 1 mm per IEC 68-2-6 Amplitude : 0.25 mm per IEC 68-2-6 |
Weight |
1.21 lbs (550g) |
External Influences |
Influence of Temperature |
£150 ppm. / K or 0.15% per 10K° |
Safety Reference Specifications |
Safety Ratings |
EN 61010-2-32 |
Agency Approvals |
CE Mark |