AC Current range |
AC (RMS or Peak value)200.0 or 2000 A AC, 2 ranges (±1.3 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)200.0 or 2000 A AC, 2 ranges (±1.3 % rdg. ±13 dgt. at 50 or 60Hz), Effective value rectifier |
DC Current range |
DC (Average or Peak value)200.0 or 2000 A DC, 2 ranges (±1.3 % rdg. ±3 dgt.) |
AC Voltage range |
AC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±7 dgt. at 50 or 60Hz), Effective value rectifier |
DC Voltage range |
DC (Average or Peak value)30.00 to 600 VDC, 3 ranges (±1.0 % rdg. ±3 dgt.) |
Frequency Measurement: |
10 to 1000 Hz, 2 ranges (±0.3 % rdg. ±1 dgt.) |
Analog Output |
DC, or AC 1 V /f.s. ,Level output: with REC mode, Waveform output: with MON mode |
Frequency characteristics (at AC current / voltage) |
DC, 10 to 1 kHz |
Display Section |
Current / 2500 dgt. Voltage / 3750 dgt. Bar graph / 35 seg |
Sampling Rate |
2 or 4 times/sec (Slow: 1 times/3 sec) |
Crest Factor (RMS) |
2.5 (1.7 at 600 A range), 1.42 (2000 A range) |
Max. Circuit Voltage |
600 V AC rms (insulated wire) |
Power Supply |
6F22(006P) × 1 (Continuous use 25 hours), or AC adapter |
Dimensions |
62 mm(2.44 in)W × 260 mm(10.24 in)H × 39 mm(1.54 in)D |
Accessories |
9207-10 TEST LEAD (1), 9345 CARRYING CASE (1), Hand strap (1) |