General Specifications |
Display pressure range |
Depending on pressure type, pressure unit (refer to '▣ Rated Pressure and Max. Display Pressure Range') |
Power supply |
12-24VDC ±10%(ripple P-P: max. 10%) |
Power consumption |
Max. 3W |
Current consumption |
Max. 100mA (adds 20mA for RS485 communication.) |
Number of input channels |
4 EA |
Input method |
DC4-20mA |
Power for external sensor |
12-24VDC , 40mA for each channel (max. current of 1-4CH: max. 100mA, max. current of 5-8CH: max. 100mA) |
Control output Hysteresis |
Min. display interval |
Control output Repeat error |
±0.1% F.S. ±min. display interval |
Control output Response time |
2.5ms, 100ms, 500ms, 1000ms |
Control output Protection circuits |
Output short over current protection, reverse power polarity protection circuit |
Display digit |
PV display part, SV display part: 4-digit, channel display part: 1-digit |
Display method Display part |
7-segment LED method
ᆞPV display part: red or green ᆞSV display part: green ᆞChannel display part: red |
Display method Output indicator |
8 (OUT1, OUT2: 4 for each) |
Display accuracy |
±0.1% ±2-digit (at 23 ±5°C) |
Control output and display temperature |
0 to 50°C: ±0.2% F.S. ±2-digit (based on 25°C), -10 to 0°C: ±0.3% F.S. ±2-digit |
Communication |
RS485 communication output(Modbus RTU) |
Connection Input |
Sensor connector (for CNE-P04, sold separately) terminal |
Connection Output |
Hirose connector 20-pin (HIF3BA-20D-2.54R, flat cable 20-wire, sold separately) terminal |
Insulation resistance |
100MΩ or more (500VDC megger basis) |
Dielectric strength |
1,000VAC 50/60Hz for 1 min (between power terminal and case), 500VAC 50/60Hz for 1 min (between power terminal and RS485 terminal) |
Vibration |
1.5mm amplitude at frequency of 10 to 50Hz (for 1 min) in each X, Y, Z direction for 2 hours |
Environment Ambient temperature |
-10 to 50°C, storage: -20 to 60°C |
Environment Ambient humidity |
30 to 85%RH, storage: 30 to 85%RH |
Accessories |
Bracket |
Weight |
Approx. 108g (approx. 65g) |