Leakage Current Testers

 
Simpson 228 - AC/DC Leakage Current Tester
Catalog: 40027
  • Maximum Current AC: 100 mA (0.1 AWhat's This?)
  • Maximum Voltage AC: 300 V
  • Unique Features: Let-Go, Reaction, and Burn Hazard Response Networks
  • Maximum Voltage DC: 300 V
  • Storage: N/A
  • Product Weight: 1.4 KILOS (3.09 LBSWhat's This?)

List Price: $975.56

Your Price: $874.95

Sign-in for EDU Pricing!

In Stock:
  • View Payment Options
Hioki CT7116 AC Clamp On Sensor 6A
  • Maximum Current AC: 6 A
  • Minimum Current AC: 5 mA
  • Product Weight: 12 OUNCES (0.75 LBSWhat's This?)
  • Product Height: 1.9 IN
  • Product Length: 6.7 IN
  • Product Width: 3 IN

Your Price: $318.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options

Your Price: $3,670.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Instek GLC-9000 Leakage Current Tester
  • Test Method (Safety): IEC 60601-1, IEC 60990
  • Test Type Hipot: AC, DC
  • Max Trip Current DC Test: 25 mA
  • Min Trip Current DC Test: 50 uA (0.05 mAWhat's This?)
  • Programmable (hipot): Yes
  • Maximum Current AC: 75 mA (0.075 AWhat's This?)

List Price: $2,329.00

Your Price: $2,212.55

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Hioki ST5540 Leak Current HiTester Medical IEC Standard
  • Test Method (Safety): IEC 60601-1, JIS T 0601-1
  • Maximum Current AC: 75 mA (0.075 AWhat's This?)
  • Maximum Current DC: 50 mA (0.05 AWhat's This?)
  • Minimum Current AC: 50 uA (0.05 mAWhat's This?)
  • Minimum Current DC: 50 uA (0.05 mAWhat's This?)
  • Unique Features: Designed for testing medical electrical equipment

Your Price: $4,389.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Simpson 229-2 AC Leakage Current Tester
Catalog: 12267
  • Maximum Current AC: 10 mA (0.01 AWhat's This?)
  • Maximum Current DC: N/A
  • Minimum Current AC: 0 mA
  • Minimum Current DC: N/A
  • Maximum Voltage AC: 300 V
  • Unique Features: Compensated to Approximate Dalziel's Perception Curve

List Price: $631.52

Your Price: $552.58

Sign-in for EDU Pricing!

In Stock:
Associated Research 00620L - LINECHEK II, Fully Automated Leakage Current Tester
  • Calibration Included: NIST Calibration
  • Country of Origin: Taiwan

Your Price: $8,399.00

In Stock:
Chroma 11200 - Capacitor Leakage Current / IR Meter 650V
  • Maximum Current DC: 20 mA (0.02 AWhat's This?)
  • Minimum Current DC: 0.001 uA (0.000001 mAWhat's This?)
  • Maximum Voltage DC: 650 V
  • Accuracy: 0.3%
  • Warranty: 1 YEARS
  • Interfaces I/O: RS-232

Your Price: $2,908.00

In Stock:
Chroma 11200-800 - Capacitor Leakage Current/IR Meter (800 V)
  • Maximum Current DC: 20 mA (0.02 AWhat's This?)
  • Minimum Current DC: 0.001 uA (0.000001 mAWhat's This?)
  • Maximum Voltage DC: 800 V
  • Accuracy: 0.3%
  • Warranty: 1 YEARS
  • Safety Approval: CE

Your Price: $3,639.00

In Stock:
Chroma 11200-CHK - Capacitor Leakage Current / IR Meter (650V) with GPIB and Contact Check
  • Maximum Current DC: 20 mA (0.02 AWhat's This?)
  • Minimum Current DC: 0.001 uA (0.000001 mAWhat's This?)
  • Maximum Voltage DC: 650 V
  • Accuracy: 0.3%
  • Warranty: 1 YEARS
  • Safety Approval: CE

Your Price: $3,634.00

In Stock:
Megger 220015V2 - 15 kV DC Dielectric Test Set
Catalog: 220015V2
  • Minimum Current DC: 2 mA
  • Maximum Voltage AC: 15 kV (15000 VWhat's This?)
  • Maximum Voltage DC: 0 V
  • Accuracy: +/- 2% of full scale
  • Shipping Weight: 40.50 LBS
  • Country of Origin: United States

Your Price: $10,970.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Wohler 7135 - DP700 Leakage Tester
Catalog: 7135
  • Warranty: 1 YEARS
  • Interfaces I/O: USB
  • Data Logging: Yes
  • Country of Origin: Germany

List Price: $7,290.00

Your Price: $6,561.00

Sign-in for EDU Pricing!

In Stock:
null
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Leakage Current Testers

A Leakage Current Testers primary objective is to measure leakage current before it becomes a danger to the operator or patient (medical use). Leakage Current (Touch Current) can be dangerous! Electrical devices are typically designed with sufficient insulation, so that operators do not experience electrical shock. However, insulation may deteriorate over time. One of the largest applications for a Leakage Current Tester is in the medical industry. Patient and operator safety and health, especially in a Medical environment, includes requiring leakage current testing on most equipment.

Equipment manufacturers and those doing repairs must adhere to for Leakage Current Standards. These Standards are in accordance with IEC, UL, JIS, ANSI, VDE, etc.

Markets for Leakage Current Testers
  • Medical
  • Industrial
  • Residential
  • Consumer Electronics
  • Service
  • Laboratory
  • Production
Leakage Current Tester applications
  • General Industrial Electrical Use
  • Medical Standard Equipment
  • Medical Emergency Equipment
  • Computers
  • Residential Appliances
  • Electrical Toys and Monitors

The test is performed by applying a voltage across the conductor or circuit, where a leakage current is measured across the insulation. For Medical Electrical Test and Monitoring Equipment, it is recommended to always use an isolation transformer when measuring leakage current. Medical-use electrical devices use a step-up isolation transformer or similar component operating at 110% of the rated supply voltage as the power supply for the device under test.

Key features to consider for selection of Leakage Current Testers
  • As a class, they are an economical tester to comply with standards governing electrical devices
  • Capability for required standards IEC, JIS, UL, DIN VDE, ANSI, etc.
  • Selectable test current
  • Polarity switching reduces cycle time
  • Rated currents to meet new Standards
  • Touch panel for interactive operation.
  • Complete communications functionality
  • External I/O Support
  • Automatic testing for production line applications
  • Memory storage of programmed tests
  • Memory storage of test results
  • Report function capability
  • Measure housing leakage current
  • Single phase or three phase capability
  • Capable of 120VAC or 240 VAC appliance testing
     
The safety of human life and personnel is always the first concern when using any electrical device. These devices are designed to meet many, if not all, of these safety requirements.

Electrical Safety Test Methods for Equipment


Powered equipment from hand tools, appliances, industrial equipment, and instruments to medical devices and more are tested for electrical safety to various global standards.

For example, IEC 60990 Standard discusses the safety involving the flow of leakage or touch current through the human body. The effect of electric current on a human body can be extremely dangerous. It provides measuring methods for the four body responses:

• Perception
• Reaction
• Let-Go
• Electric Burn

JIS T 0601-1 is the Japanese modification of the existing IEC 60601-1 Safety Standard. IEC 60601-1 is the accepted standard for safety testing of all medical equipment. Both consider safety to be the primary concern.

Here are more standards to consider. Note: It is a partial list. Also, if a test instrument we offer does not specifically list a particular test method, that does not necessarily mean it cannot be used. Since there are so many test methods, the litereture may not enumerate them all. Please contact us with the specific method and we can research it for you.

Partial List of Global Electrical Safety Standards
ANSI / AAMI EC11 Diagnostic Electrocardiographic Devices U.S.
ANSI / AAMI EC13 Cardiac Monitors, Heart Rate Meters, and Alarms U.S.
ANSI / AAMI EC53 ECG Cables and Leadwires U.S.
ANSI / IEEE C37.60 High-voltage Switchgear and Controlgear U.S.
ANSI A92.2 Vehicle Mounted Elevating and Rotating Work Platforms U.S.
BS EN 61557 Electrical safety in low voltage distribution systems up to 1000VAC and 1500VDC British
BS 7671 Requirements for Electrical Installations, IEE Wiring Regulations British
DIN VDE 0701-0702 0701 Repair, Modification, and Inspection of Electrical Equipment. 0702 Periodic Testing of Electrical Equipment German
EN 55024 Information Technology Equipment Europe
GR-1089 Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunication Equipment U.S.
IEC 384-14, Annex A, Table VXI Capacitors Europe
IEC 50144
BS EN 50144
Safety of Hand-held Electric Motor Operated Tools Europe/ British
IEC 60065 Audio, Video, and Similar Electronic Apparatus - Safety Requirements Europe
IEC 60204-1 Safety of Machinery Europe
IEC 60335-1 Safety of Electrical Household Appliances Europe
IEC 60601-1 Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance Europe
IEC 60601-2 Medical Electrical Equipment - Part 2: Particular Requirements for the Basic Safety and Essential Performance of Gamma Beam Therapy Equipment Europe
IEC 60745 Safety of Hand-operated Motor-driven Electric Tools Europe
IEC 60950-1 Safety of Information Technology Equipment Europe
IEC 60990 Methods of Measurement of Touch Current and Protective Conductor Current Europe
IEC 61010-1 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Europe
IEC 61029 Safety of Transportable Motor-Operated Electric Tools Europe
IEC 61730-2 Photovoltaic (PV) Module Safety Qualification - Part 2 Requirements for Testing Europe
IEC 61813 Live Working - Care, Maintenance and In-service testing of Aerial Devices with Insulating Booms Europe
IEC 62052-11 Electricity Metering Equipment (AC) - General Requirements, Tests, and Test Conditions Europe
IEC 62353 Medical Electrical Equipment - Recurrent Test and Test After Repair of Medical Electrical Equipment Europe
IEC 62446 Grid Connected Photovoltaic Systems - Minimum requirements for System Documentation, Commissioning Tests and Inspection Europe
ITU-T K.20 Resistibility of Telecommunication Equipment Installed in a Telecommunications Centre to Overvoltages and Overcurrents Europe
ITU-T K.21 Resistibility of Telecommunication Equipment Installed in Customer premises to Overvoltages and Overcurrents Europe
JIS B8561 Vending Machines - Test Method Japan
JIS C9250 Microwave Ovens Japan
JIS T 0601-1 Electrical Safety Standard for Medical Devices Japan
TE-001, Para. 17 Telephone Surge Test Equipment: For the Lightning Protection Tests South Africa
TIA/EIA/IS-968 Telecommunications Telephone Terminal Equipment Technical Requirements for Connection of Terminal Equipment to the Telephone Network. (formerly known as FCC Part 68) U.S.
uL 492 Power-operated Radio Receiving Appliances U.S.
uL 746E Polymeric Materials - Industrial Laminates, Filament Wound Tubing, Vulcanized Fibre, and Materials Used In Printed-Wiring Boards (Section 19 covers requirements for conformal coatings used instead of electrical spacings to increase the dielectric withstand voltage between traces on a printed-wiring board.) U.S.
uL 2231-1 Standard for Safety for Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits: General Requirements U.S.
uL 2231-2 Standard for Safety for Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits: particular Requirements for Protection Devices for Use in Charging Systems U.S.




X