Comparison of the Rigol DS4034, Tektronix TDS3034c, and the Agilent DSOX3034a Digital Oscilloscopes:


Rigol DS4034 comes with Rigol's UltraVision Technology, allowing for higher waveform capture rates of up to 110,000 wfms/s, real time waveform record and replay functionality of up to 200,000 frames, and multi-level intensity grading display, as well as a 9 inch WVGA 256 level intensity grading display, and a lower noise floor with a minimum vertical sensitivity of 1mV/div.

Tektronix TDS3034c allows you to accurately characterize a wide range of signal types on all channels simulataneously.

Agilent DSOX3034a includes Agilent's MegaZoom IV technology, enabling a faster waveform update rate with responsive deep memory acquisitions.
 
Rigol_DS4022Tektronix TDS3034CAgilentDSOX3024A
The key differences are listed here:

 
 Feature / Model DS4034 TDS3034c DSOX3034a
Bandwidth 350 MHz 300 MHz 350 MHz
Memory 140 MP 10 kP 2 MP
Rise Time 1 ns 1.17 ns 1 ns
Update Rate 110,000 Wfms/s 3,600 Wfms/s 1,000,000 Wfms/s
Data Logging Yes Yes Yes
UltraVision Technology Yes No No
Sampling Rate 4 GS/s 2.5 GS/s 2 GS/s
Analog Channels 4 4 4
For the Full Details of the differences please see below:
(click the ? for explanations of specification terms)


ModelTektronix TDS3034CAgilent DSOX3034ARigol DS4034
ProductOSCILLOSCOPE; DPO, 300MHZ, 2.5 GS/S, 4 CHANNEL, COLOR DISPLAY, CERTIFICATE OF...Oscilloscope, 4-channel, 350MHz350 MHz Digital Oscilloscope with 4 channels, 4GS/s, 140Mpoint memory
Rating(0)(0)(1)
Price
In Stock

Oscilloscopes/Digital Oscilloscopes

Bandwidth300 MHz350 MHz350 MHz
Channels444
Sampling Rate2.5 GS/S2 GS/S4 GS/S
Memory10 KP [kilopoints] (10 kB)1 MP [megapoints] (1024 kB)140 MB (143360 kB)
Rise Time1.17 ns 1 ns1 ns
Screen Size6.5 IN8.5 IN9 IN
Bits888

Test Equipment General Attributes

Unique Features 300 MHz bandwidth model
4 channels
Sample rates up to 5 GS/s real-time on all channels
10 k standard record length on all channels
3,600 wfms/s continuous waveform capture rate
Suite of advanced triggers
Upgradability: add bandwidth, digital channels, or WaveGen after purchase
Optional serial protocol analysis applications including: I²C, SPI, RS232, UART, CAN, LIN, I²S, MIL-STD 1553, ARINC 429 and FlexRay
Additional applications including: Segmented memory, mask testing, advanced math and HDTV video
Power analysis
140 M Samples Memory Standard
Warranty3 YEARS3 YEARS3 YEARS
Warranty DetailsReturn to Agilent Warranty- 3 Years
Interfaces I/O GPIB, LAN / Ethernet, RS-232, VGA or SVGA Out Analog Output, GPIB, LAN / Ethernet, LXI, Analog Input   LAN / Ethernet, LXI, USB Host, USB, VGA or SVGA Out