Bandwidth |
100 MHz |
100 MHz |
300 MHz |
300 MHz |
500 MHz |
500 MHz |
Channels |
2 |
4 |
2 |
4 |
2 |
4 |
Sample rate on each channel |
1.25 GS/s |
1.25 GS/s |
2.5 GS/s |
2.5 GS/s |
5 GS/s |
5 GS/s |
Maximum record length |
10 K points on all models |
Vertical resolution |
9 Bits on all models |
Vertical sensitivity (/div) |
1 mV - 10 V on all models |
Vertical accuracy |
±2% on all models*1
*1Derated at 0.025%/°C for temperatures above +30°C and below +18°C. |
Max input voltage (1 Megaohm) |
150 VRMS CAT I on all models (300 V CAT II with standard 10X probe) |
Position range |
± 5 div on all models |
BW limit |
20 MHz |
20 MHz |
20, 150 MHz |
20, 150 MHz |
20, 150 MHz |
20, 150 MHz |
Input coupling |
AC, DC, GND on all models |
Input impedance selections |
1 Megaohm in parallel with 13 pF or 50 Ohm |
Range (/div) |
4 ns - 10 s/div |
4 ns - 10 s/div |
2 ns - 10 s/div |
2 ns - 10 s/div |
1 ns - 10 s/div |
1 ns - 10 s/div |
Accuracy |
20 ppm |
20 ppm |
20 ppm |
20 ppm |
20 ppm |
20 ppm |
Display monitor |
Color LCD |
DPO |
Captures and displays complex waveforms, random events and subtle patterns in actual signal behavior. DPOs are able to provide 3 dimensions of signal information in real time: Amplitude, time and the distribution of amplitude over time. |
Peak Detect |
High frequency and random glitch capture. Captures glitches as narrow as 1 ns. |
WaveAlert |
Monitors the incoming signals on all channels and alerts the user to any waveform that deviates from the normal waveform being acquired. |
Sample |
Sample data only. |
Envelope |
Max/min values acquired over one or more acquisitions. |
Average |
Waveform data from 2 to 512 (selectable) acquisitions is averaged. |
Single Sequence |
Use the Single Sequence button to capture a single triggered acquisition sequence at a time. |
Main Trigger Modes |
Auto (supports Roll Mode for 40 ms/div and slower), Normal. |
B Trigger |
Trigger after time or events. |
Trigger After Time Range |
13.2 ns to 50 s. |
Trigger After Events Range |
1 to 9,999,999 events. |
External Trigger Input |
>1 Megaohm in parallel with 17 pF; Max input voltage is 150 VRMS. |
Edge |
Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: DC, noise reject, HF reject, LF reject. |
Video |
Trigger on all lines or individual line, odd/even or all fields or analog HDTV formats (1080i, 1080p, 720p, 480p). See optional TDS3VID and TDS3SDI application modules for extended video triggering and measurement features. |
Logic (requires TDS3TRG) |
PATTERN: Specifies AND, OR, NAND, NOR when true or false for a specific time.
STATE: Any logic state. Triggerable on rising or falling edge of a clock. Logic triggers can be used on combinations of 2 inputs (not 4). |
Pulse (requires TDS3TRG) |
WIDTH (or GLITCH): Trigger on pulse width less than, greater than, equal to or not equal to a selectable time limit ranging from 39.6 ns to 50 s.
RUNT: Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.
SLEW RATE: Trigger on pulse edge rates that are either faster or slower than a set rate. Edges can be rising, falling or either. |
Comm (requires TDS3TMT) |
Provides isolated pulse triggering required to perform DS1/DS3 telecommunications mask testing per ANSI T1.102 standard. |
Alternate |
Sequentially uses each active channel as a trigger source. |
Automatic Waveform Measurements |
Period, Frequency, +Width, -Width, Rise Time, Fall Time, +Duty Cycle, -Duty Cycle, +Overshoot, -Overshoot, High, Low, Max, Min, P-P, Amplitude, Mean, Cycle Mean, RMS, Cycle RMS, Burst Width, Delay, Phase, Area*1, Cycle Area*1.
Display any four measurements from any combination of waveforms.
*1Requires TDS3AAM module. |
Thresholds |
Settable in percentage or voltage. |
Gating |
Measurements can be gated using the screen or vertical cursors. |
Deskew |
Channel-to-channel deskew ±10 ns may be manually entered for better timing measurements and more accurate math waveforms. |
Arithmetic Operators |
Add, subtract, multiply, divide. |
Autoset |
Single-button, automatic setup on selected input signal for vertical, horizontal and trigger systems. |
Waveform Style |
Dots, vectors and variable persistence. |
Graticules |
Full, grid, cross-hair, frame, NTSC, PAL, SECAM, vectorscope 100% and 75% color bars (with optional TDS3VID and TDS3SDI video application modules). |
Format |
YT, XY and Gated XYZ (XY with Z-axis blanking available on TDS30X4C only). |
Hardcopy Port (standard) |
Centronics-type parallel. |
TDS3GV Communications Module |
GPIB (IEEE -488.2) programmability: Full talk/listen modes; Control of all modes, settings and measurements.
VGA: Monitor output for direct display on large VGA-equipped monitors. DB-15 female connector, 31.6 kHz sync rate, EIA RS-343A compliant.
RS-232-C interface programmability: Full talk/listen modes; Control of all modes, settings and measurements. Baud Rate up to 38,400. DB-9 male connector.
Programmer manual: 071-0381-01. |
Graphics File Formats |
Interleaf (.img), TIF, PCX (PC Paintbrush), BMP (Microsoft Windows) and Encapsulated Postscript (EPS). |
Printer Formats |
Bubblejet, DPU-3445, Thinkjet, Deskjet, Laserjet, Epson (9- and 24-Pin). |
Temperature |
+5 to +50°C (operating), -20 to +60°C (nonoperating). |
Humidity |
20% to 80% RH below 32°C, derate to 30% RH at 45°C (operating), 5% to 90% RH below 41°C, derate to 30% RH at 60°C (nonoperating). |
Altitude |
to 3,000 m (operating), 15,000 m (nonoperating). |
Electromagnetic Compatibility |
Meets or exceeds EN55011 Class A radiated and conducted emissions; EN50082-1; FCC 47 CFR, Part 15, Subpart B, Class A; Australian EMC framework; Russian GOST EMC regulations. |
Safety |
UL3111-1, CSA1010.1, EN61010-1, IEC61010-1. |