Model | Fluke 175 | Fluke 177 |
---|
Product | Fluke 175 ESFP True-RMS AC/DC Digital Multimeter, 1000V | Fluke 177 ESFP True-RMS AC/DC Digital Multimeter, 1000V with Analog Bargraph and Backlight |
---|
Rating | (6) | (12) |
---|
Price | | |
---|
In Stock | | |
---|
Multimeters |
Style | Hand-Held | Hand-Held |
Measures AC V | Yes | Yes |
Measures DC V | Yes | Yes |
Measures AC A | Yes | Yes |
Measures DC A | Yes | Yes |
True RMS | Yes | Yes |
Maximum Voltage AC | 1000 V | 1000 V |
Resolution AC Volts | 0.1 mV Resolution AC Volts Range / Resolution 600.0 mV / 0.1 mV 6.000V / 0.001V 60.00V / 0.01V 600.0V / 0.1V 1000V / 1V | 0.1 mV Resolution AC Volts Range / Resolution 600.0 mV / 0.1 mV 6.000V / 0.001V 60.00V / 0.01V 600.0V / 0.1V 1000V / 1V |
Maximum Voltage DC | 1000 V | 1000 V |
Resolution DC Volts | 0.1 mV Resolution DC Volts Range / Resolution 600.0 mV / 0.1 mV 6.000V / 0.001V 60.00V / 0.01V 600.0V / 0.1V 1000V / 1V | 0.1 mV Resolution DC Volts Range / Resolution 600.0 mV / 0.1 mV 6.000V / 0.001V 60.00V / 0.01V 600.0V / 0.1V 1000V / 1V |
Maximum Current AC | 10 A | 10 A |
Minimum Current AC | 0.01 mA | 0.01 mA |
Resolution AC Current | 0.01 mA Resolution AC Current AC Amps - (True-rms) Range / Resolution 60.00 mA / 0.01 mA 400.0 mA / 0.1 mA (600 mA for 18 hrs) / 0.001A 6.000A / 0.001A (45 Hz to 1 kHz) : 10.00A / 0.01A (20A for 30s) | 0.01 mA Resolution AC Current AC Amps - (True-rms) Range / Resolution 60.00 mA / 0.01 mA 400.0 mA / 0.1 mA (600 mA for 18 hrs) / 0.001A 6.000A / 0.001A (45 Hz to 1 kHz) : 10.00A / 0.01A (20A for 30s) |
Maximum Current DC | 10 A | 10 A |
Minimum Current DC | 0.01 mA | 0.01 mA |
Resolution DC Current | 0.01 mA Resolution DC Current AC Amps - (True-rms) Range / Resolution 60.00 mA / 0.01 mA 400.0 mA / 0.1 mA (600 mA for 18 hrs) / 0.001A 6.000A / 0.001A (45 Hz to 1 kHz) : 10.00A / 0.01A (20A for 30s) | 0.01 mA Resolution DC Current AC Amps - (True-rms) Range / Resolution 60.00 mA / 0.01 mA 400.0 mA / 0.1 mA (600 mA for 18 hrs) / 0.001A 6.000A / 0.001A (45 Hz to 1 kHz) : 10.00A / 0.01A (20A for 30s) |
Basic Accuracy V DC | 0.15 Basic Accuracy V DC ± (0.15%+2 counts ) | 0.09 Basic Accuracy V DC ± (0.09%+2 counts) |
# Digit Display | 3.75 | 3.75 |
Counts | 6000 . Counts Updates 4 x second | 6000 . Counts Updates 4 x second |
Backlight | No | Yes |
Manual/Autoranging | Both | Both |
Decibels | No | No |
Resistance | Yes Resistance Accuracy ± (0.9%+1 counts ) Max. resolution 0.1 Ω Maximum 50 MΩ 50 MΩ Accuracy: (1.5% + 3 counts )
Range / Resolution 600.0Ω 0.1Ω 6.000 kΩ 0.001 kΩ 60.00 kΩ 0.01 kΩ 600.0 kΩ 0.1 kΩ 6.000 MΩ 0.001 MΩ 50.00 MΩ 0.01 MΩ | Yes Resistance Accuracy ± (0.9%+1 counts ) Max. resolution 0.1 Ω Maximum 50 MΩ 50 MΩ Accuracy: (1.5% + 3 counts )
Range / Resolution 600.0Ω 0.1Ω 6.000 kΩ 0.001 kΩ 60.00 kΩ 0.01 kΩ 600.0 kΩ 0.1 kΩ 6.000 MΩ 0.001 MΩ 50.00 MΩ 0.01 MΩ |
Frequency | Yes Frequency Accuracy* ± (0.1%+1) Max. resolution 0.01 Hz Maximum 100 kHz | Yes Frequency Accuracy* ± (0.1%+1) Max. resolution 0.01 Hz Maximum 100 kHz |
Capacitance | Yes Capacitance Accuracy* ± (1.2%+2 counts ) 9999 µF - 10% Accuracy typical 9999 Count Display Max. resolution 1 nF Maximum 10,000 µF
Range / Resolution 1000 nF / 1 nF 10.00 µF / 0.01 µF 100.0 µF / 0.1 µF 9999 µF / 3 1 µF | Yes Capacitance Accuracy* ± (1.2%+2 counts ) 9999 µF - 10% Accuracy typical 9999 Count Display Max. resolution 1 nF Maximum 10,000 µF
Range / Resolution 1000 nF / 1 nF 10.00 µF / 0.01 µF 100.0 µF / 0.1 µF 9999 µF / 3 1 µF |
Temperature | No | No |
Diode Testing | Yes Diode Testing Range: 2.400V Resolution 0.001 V Accuracy (1 % + 2 counts ) | Yes Diode Testing Range: 2.400V Resolution 0.001 V Accuracy (1 % + 2 counts ) |
CAT Rating | IV CAT Rating Overvoltage category EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV | IV CAT Rating Overvoltage category EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV |
CAT Voltage | 1,000 V, 600 V CAT Voltage EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV | 1,000 V, 600 V CAT Voltage EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV |
Intrinsically Safe | No | No |
Peak Hold | No Peak Hold HOLD: freezes the display at the push of a button Auto HOLD: Display holds present reading until it detects new stable input, then the meter beeps and displays new reading | No Peak Hold HOLD: freezes the display at the push of a button Auto HOLD: Display holds present reading until it detects new stable input, then the meter beeps and displays new reading |
Overload Protector | Yes | Yes |
Kelvin 4-Wire Measurement Capability | No | No |
Wireless Display | No | No |
Data Hold | Yes | Yes |
Low-Pass Filter | No | No |
Test Equipment General Attributes |
Unique Features | •Manual and automatic ranging •Display Hold and Auto Hold •Frequency and capacitance measurements •Resistance, continuity and diode measurements •Min-max-average recording •Closed case calibration through front panel •Ergonomic case with integrated protective holster | •Manual and automatic ranging •Display Hold and Auto Hold •Frequency and capacitance measurements •Resistance, continuity and diode measurements •Min-max-average recording •Closed case calibration through front panel •Ergonomic case with integrated protective holster
|
Warranty | 1 LIMITED LIFETIME (1 YEARS) | 1 LIMITED LIFETIME (1 YEARS) |
Warranty Details | Limited Lifetime Warranty | Limited Lifetime Warranty |
Safety Approval | CSA, UL Safety Approval TUV listed and VDE Pending | CSA, UL |
Interfaces I/O | Analog Output, Analog Input | Analog Output, Analog Input |
Product Weight | 0.93 LBS | 420 GRAMS (0.926 LBS) |
Product Height | 1.69 IN | 1.69 IN |
Product Length | 7.28 IN | 7.28 IN |
Product Width | 3.54 IN | 3.54 IN |
Data Logging | No | No |
Calibration Included | Factory Calibration Calibration Included Factory Certification without certification | Factory Calibration Calibration Included Factory Certification without certification |
Battery Type | 9v | 9v |
Power Supply Voltage | Battery Powered | Battery Powered |
Country of Origin | United States | United States |