| Model |
MCA3027 |
| Max Frequency |
27 GHz |
| Channels |
2 - 300 MHz
1 - 27 GHz |
| Frequency Resolution |
12 digit/s |
| Time Resolution |
100 ps |
| Voltage Resolution |
3 mV |
| Measurement Speed to Internal Memory |
250k measurement/s
750k results |
| Talker-Only Output (GPIB/USB) |
No |
| Individually Triggered Measurements |
500 Readings |
| Block Transfer Speed |
5K Measurement/s |
| Reference Input |
1 MHz, 5 MHz, or 10 MHz; 0.1 to 5 VRMS sine; impedance ≥1 kΩ |
| Reference Output |
10 MHz; >1 VRMS sine into 50 Ω |
| Impedance |
Approx. 1 kΩ |
| Frequency range |
DC to 80 MHz |
| Compatibility |
IEEE 488.2-1987, SCPI 199953131A Compatibility mode |
| Interface Functions |
SH1, AH1, T6, L4, SR1, RL1, DC1, DT1, E2 |
| Max Measurement Rate GPIB |
5k readings/s (Block mode) 500 readings/s (individual GET triggered) |
| Max Measurement Rate To internal memory |
250k readings/s |
| Internal Memory Size |
750k readings |
| USB |
USB Version 2.0 full speed (11 Mb/s) |
| Time Delay Range |
20 ns to 2 s, 10 ns resolution |
| External start and stop arming |
Arming can be used to synchronize the frequency and power measurements with the start of a burst signal. Minimum burst length must exceed 100 μs. |
| Modes |
Start and Stop Arming |
| Start-time Delay Range |
20 ns to 2 s, 10 ns resolution |
| Measuring Time |
20 ns to 1000 s for frequency, burst, and period average. Single cycle for other measuring functions |
| Time-base Reference |
Internal, external, or automatic |
| Display Hold |
Freezes the result, until a new measurement is initiated through a restart |
| Limit Alarm |
Graphical indication on front panel and/or SRQ through GPIB |
| Limit Values |
Lower limit, upper limit |
| Settings |
Off, or alarm if value is above, below, inside, or outside limits |
| On Alarm |
Stop or Continue |
| Number of Stored Instrument Setups |
20. Instrument setups are saved/recalled from internal nonvolatile memory. 10 can beset as user-protected |
| Mode |
Closed case, menu controlled |
| Calibration Frequencies |
0.1, 1, 5, 10, 1.544, and 2.048 MHz |
| Functions |
Maximum, Minimum, Mean, ΔMax-Min, Standard Deviation, and Allan Deviation |
| Display |
Numeric, histograms, or trend plots |
| Sample Size |
2 to 2 × 109 samples |
| Limit Qualifier |
Off, or capture values above, below, inside, or outside limits |
| Measurement Pacing |
Pacing Time Range: 4 μs to 500 s |
| Math functions |
(K*X+L)/M, (K/X+L)/M, or X/M-1. X is current reading and K, L, and M are constants; set using the keyboard or as frozen reference value (X0 ) |
| Display |
Numeric + Graphic. Backlit LCD graphics screen for menu control, numerical readout, and status information |
| Number of digits |
14 digits in Numerical mode |
| Resolution |
320 × 97 pixels |
| Height |
90 mm (3.6 in.) |
| Width |
210 mm (8.25 in.) |
| Depth |
395 mm (15.6 in.) |
| Net |
2.7 kg (5.8 lb.) |
| Shipping |
3.5 kg (7.5 lb.) |
| Temperature Operating |
0 °C to +50 °C (+32 °F to +122 °F) |
| Temperature Storage |
-40 °C to +71 °C (-40 °F to +160 °F) |
| Humidity |
5-95% (+10 °C to +30 °C) (+50 °F to +86 °F)
5-75% (+30 °C to +40 °C) (+86 °F to +104 °F)
5-45% (+40 °C to +50 °C) (+104 °F to +122 °F) |
| Altitude Operating |
2,000 m (6562 ft.) |
| Altitude Storage |
12,000 m (39,370 ft.) |
| Power |
90 V to 265 VRMS, 45 to 440 Hz, <40W |
| Class |
MIL-PRF-28800F, Class 3 |
| Safety |
Directive 2006/95/EC, EN61010-1, UL61010-1, CAN/CSA C22.2 No. 61010-1 |
| EMC |
EU Directive 2004/108/EC, EN61326-1, EN61326-2-1, Class A |
| Frequency/Period, Time, Phase, Volt, Duty Cycle, Pulse, Rise Time |
Yes |
| Graphic Display of Trend, Histogram, Modulation Domain |
Yes |
| Totalize, TIE |
No |
| Programmable Pulse Output |
No |
| Continuous Measurements |
No |