Techne FDB425FR Tecal 425F "Field" Range Portable Dri-Block Calibrator 240V
Dri-Block Temperature Calibrators
The Tecal Series of Dri-Block Calibrators are used as portable temperature calibrators in a wide variety of industries for checking the calibration of thermocouples, RTDs and liquid fi lled sensors. The checking of temperature is vital in numerous industrial processes – engines, machines, boilers, pumps, storage rooms, air conditioners, compressors used in power stations, chemical plants, refineries, offshore platforms, ships, steel works and instrument companies are all typical application areas.
Tecal “Field” Range of Dri-Block Calibrators
Techne has developed a range of lightweight dry-block thermal calibrators that operate from 45°C below ambient up to 650°C, for convenient fi eld use. The three models in the Tecal F range incorporate the precision control system used on Techne’s Tecal ‘H’ models to provide excellent reliability and accuracy, with a number of improvements such as an enhanced display resolution of 0.01°C and faster heating and cooling rates. All models off er RS-232 communications and can be used with a wide range of inserts to suit different probe sizes. Automatic fan cooling is standard, with accelerated cooling probes also available.
TechneWorks Software
TechneWorks is an easy to use control software for many of our RS-232 compatible products. This software has been designed to supersede the existing Calsoft and Thermsoft software packages.
It will allow customers to carry out all the tasks previously available on Calsoft and Thermsoft, plus many new options on one new package. It is fully compatible with all Techne RS-232 Calibration products including all current models and older discontinued models such as the TU-20C.
TechneWorks software allows connection to a range of Precision Thermometers, such as the Techne Accu-Temp, ASL model F250, Accu-Temp II and the Cropico 3000 series. TechneWorks software enables you to calibrate thermometers and sensors by comparison to one of the above listed thermometers using a Techne liquid bath or dry block as a temperature source. Alternatively, the bath or dry block calibrator display can be used as the reference. After data is collected, a calibration certifi cate can be printed.
Software Features:
- Create, open and save programs with up to 20 set points.
- Specify either °C or °F.
- Specify ramp rates and hold times.
- Log data from the instrument while connected to the computer and export the data in an Excel spreadsheet.
- Open, save, view and print logged data.
- Perform a calibration where temperature of the probe is manually entered.
- Perform an automatic calibration routine where the temperature reference probes data is added automatically.
- Run a program in real time mode.
- Specify the logging interval from every 5 seconds to 60 seconds
- Free download from website