| Insulation ranges |
| Nominal Test Voltage |
1000 V, 500 V, 250 V (d.c.) |
| Measuring Range |
| All instruments |
10 k½ - 999 M½ on all ranges |
| Short Circuit Current |
1.5 mA nominal |
| Test Current on Load |
1 mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364) |
| Accuracy (at 20° C) |
±3%, ±2 digits |
| Continuity ranges |
| Measuring Range |
0,01 ½ - 99,9 ½ (0 -50 ½ on analogue scale) |
| Open Circuit Voltage |
5 V ±1 V |
| Short Circuit Current |
200 - 215 mA |
| Terminal Characteristics |
| |
| Accuracy (at 20° C) |
±3% ±2 digits |
| Zero Offset Adjust |
0 - 9 ½ |
| Continuity Buzzer |
Adjustable 1 ½ to 20 ½ Response time <20 ms |
| Resistance range MIT320/330 |
| (can be used for diode testing) |
| Measuring Range |
10 ½ - 1 M½ |
| Open Circuit Voltage |
5 V |
| Short Circuit Current |
1.5 mA |
| Accuracy (at 20° C) |
±5% ±2 digits up to 100 k½ |
| Voltage range |
| Measuring Range |
0 - 600 V a.c. (50/60 Hz) or d.c. |
| Accuracy (at 20° C) |
d.c. or a.c. (50/60 Hz) ±1%, ±2 digits |
| Temperature coefficient |
<0,1% per °C on all ranges. |
| Default voltmeter |
| (all modes except off) |
>25 V a.c. or d.c. is applied display will operate as a voltmeter. |
| Test inhibit |
If more than 50 volts is detected, testing will be inhibited. |
| AutoPower Down |
Auto power down operates after 10 minutes if left in standby mode. |
| Temperature and humidity |
| Operating Range |
-10°C to +60°C |
| Operating Humidity |
93% R.H. at +40°C max.: |
| Storage Range |
-25°C to +70°C |
| Test Result Storage (1000 results) |
| Job Number |
255 locations |
| Distribution Board no. |
99 locations |
| Circuits |
99 locations |
| Phases |
P1, P2, P3 |
Last recorded result may be recalled to the display.
All data can be downloaded to a PC using Download Manager (supplied) or Megger Powersuite Professional of Windows software |
| Communications |
USB interface |
| Environmental Protection |
IP54 |
| Fuses |
Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10 kA minimum. |
| Display shows if fuse is ruptured. |
| Safety |
Meets the requirements of IEC61010-1 Cat III 600 V phase to earth. |
| Automatic discharge |
After an insulation test the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored. |
| Power supply |
| Battery |
8 x 1,5 V cells IEC LR6 type(AA alkaline).
Rechargeable NiCd or NiMH cells may be used.
Battery condition is constantly shown on the display as a four-section bargraph. |
| Battery Life |
5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries. Weight |
| All units |
980 gms |
| Dimensions |
All units: 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches) |
| E.M.C. |
In accordance with IEC61326 including amendment No.1 |