| AC Current range: |
30.00 to 1000 A AC, 3 ranges (±1 % rdg. ±5 dgt. at 50 or 60Hz), Effective value rectifier |
| Wave peak value at AC Current: |
30.0 to 600 A peak, 3 ranges (±3 % rdg. ±5 dgt. at 50 or 60Hz) |
| AC Voltage range: |
300.0 or 600 V AC, 2 ranges (±1 % rdg. ±3 dgt. at 50 or 60Hz), Effective value rectifier |
| Wave peak value at AC Voltage: |
up to 300 or 600 V peak, 2 ranges (±3 % rdg. ±5 dgt. at 50 or 60Hz) |
| Temperature: |
-50 to 150 °C (9462 TEMPERATURE PROBE required, sold separately) |
| Mode: |
Slow/Peak/C.F./RMS/Record mode/Auto-off/Conduction |
| Frequency characteristics (at AC current / voltage): |
40 to 1000 Hz |
| Display Section: |
Digital / 3000 dgt. Bar graph / 35 seg. |
| Sampling Rate: |
2 or 4 times/sec (Slow: 1 times/3 sec) |
| Crest Factor (RMS): |
2.5 (1.7 at 600 A, 600 V range) |
| Max. Circuit Voltage: |
600 V AC rms (insulated wire) |
| Power Supply: |
6F22 (006P) × 1, Continuous use 45 hours |
| Dimensions: |
62 mm(2.44 in)W × 218 mm(8.58 in)H × 39 mm(1.54 in)D |
| Accessories: |
9207-10 TEST LEAD (1), 9399 CARRYING CASE (1), Hand strap (1) |