Rated current |
200 A AC/DC |
Max. allowable input |
400 A continuous (requires derating at frequency or temperature) |
Frequency characteristics |
Amplitude: DC to 500 kHz
Phase: DC to 300 kHz |
Amplitude and phase accuracy |
DC ±0.3 % rdg. ±0.02 % f.s. (Phase: Not defined)
DC< f ≤ 100 Hz ±0.3 % rdg. ±0.01 % f.s. (Phase: ±0.1 deg)
Defined to 500 kHz |
Basic accuracy (DC) |
Amplitude accuracy : ±0.3% rdg. ±0.02% f.s. |
Offset adjustment |
In DC measurement, adjust offset with a dial |
Power consumption |
6 VA max. (at 200 A/55 Hz, ±12 V power requirement) |
Output voltage |
0.01 V/A (voltage output with the Sensor Unit 9555-10, use with a device having a 1 MΩ input resistance or higher) |
Core diameter |
φ 20 mm (0.79 in) |
Effect of conductor position |
±0.1%rdg. or less |
Effect of external electromagnetic field |
50 mA or less (Scaled value, in a DC or 60 Hz magnetic field of 400 A/m) |
Magnetic susceptibility |
30 mA or less (Scaled value, after 200 A DC input) |
Effect of common-mode voltage |
0.05%f.s. or less (1000 V rms, DC to 100 Hz) |
Operating temperature, humidity |
-40 °C to +85 °C (-40 °F to 185 °F), 80% rh or less (with no condensation) |
Power supply |
DC ±11 V to ±15 V (Power suppled via the 9555-10, which supports 100 to 240 V AC) |
Dimensions and mass |
153 mm (6.02 in)W × 67 mm (2.64 in)H × 25 mm (0.98 in)D, cord length: 10 m, 370 g (13.1 oz) |
Accessories |
Instruction manual ×1, Mark bands ×6, Carrying Case |