| Transmission Frequency |
CMR35T: 910MHz / CMR35AT: 912.4MHz |
| Wireless Range |
Up to 333ft.(100m) with no obstructions |
| Sampling Rate |
3x/sec (not transmitting); 1x/sec (transmitting) |
| Operating Temperature/Humidity |
14° to 122°F (-10° to 50°C)/80%R.H.max |
| Storage Temperature/Humidity |
-4° to 140°F (-20° to 60°C)/70%R.H.max |
| Jaw Opening |
30mm (1.18in.) |
| LCD Size |
1.77(H) x 1.04 (W) in. (45 x 26.5 mm) |
| Voltage Measurement Range/Accuracy |
0 to 600V(AC or DC)/0.75% plus 3 counts |
| Voltage Measurement Resolution |
0.001V |
| Current Measurement Range/Accuracy |
0 to 600A(AC or DC)/1% plus 5 counts |
| Resistance Measurement Range |
0 to 40MΩ |
| Frequency Measurement Range |
0 to 100kHz |
| Transmission Span |
2, 10, 30, 60 or 120 seconds (user-selectable) |
| Input Impedance |
10MΩ |
| Continuity Threshold |
100Ω or less |
| Diode Check Voltage |
1.5V (open circuit) |
| Safety Rating |
CAT III 600V |
| Dimensions |
8.66 x 2.52 x 1.38 in. (220 x 64 x 35mm) |
| Weight |
8.85 oz. (251g) |
| Power Source |
2 "AA" batteries or external 3VDC supply @ 10 mA |
| FCC approved |
Yes |
| Reception Frequency |
CMR35: 910MHz / CMR35AR: 912.4MHz |
| Wireless Range |
333 ft. (100m) with no obstructions |
| Sampling Rate |
3x/sec |
| Operating Temperature |
14° to 122°F (-10° to 50°C) |
| Storage Temperature |
-4° to 140°F (-20° to 60°C) |
| LCD Size |
2.05 x 1.14 in. (52 x 29mm) |
| Dimensions |
7.05 x 2.83 x 1.26 in. (179 x 72 x 32mm) |
| Weight |
6.24 oz. (177g) |
| Power Source |
2 "AA" batteries or external 3VDC supply @ 10 mA |
| Systems & Componenets |
| CMR35 System |
FCC ID Y7YT0035G01 - 910 MHz |
| CMR35T |
Wireless Clamp Meter-Transmitter |
| CMR35R |
Wireless Controller Data Logger-Receiver |
| CMR35A System |
FCC ID Y7YTA035G01 - 912.4 MHz |
| CMR35AT |
Wireless Clamp Meter-Transmitter |
| CMR35AR |
Wireless Controller Data Logger-Receiver |