| FLIR CM275 Specifications |
| IR Resolution |
160 × 120 (19,200 pixels) |
| Sensitivity |
150 mK |
| Size (L x W x H) |
43 x 89 x 241 mm (1.7 x 3.5 x 9.5 in) |
| Warranty |
10 Years on Product and Detector* |
| Weight |
426 g (15 oz) |
| Worklights |
Yes |
| Connections & Communications |
| Connectivity |
Bluetooth® |
| Environmental |
| Drop test |
2 m |
| Emissivity Settings |
4 Presets with Custom Adjustment |
| Imaging & Optical |
| Color palettes |
Iron, Rainbow, Grayscale |
| Display Size |
2.4 in TFT screen |
| Focus |
Fixed |
| Gallery |
8549 |
| Thermal Imaging Detector |
FLIR Lepton® microbolometer |
| Field of View [V x H] |
38.6° x 50.0° |
| Measurement & Analysis |
| AC Current |
Range 600.0A / Basic Accuracy ±2.0% |
| AC/DC Voltage |
Range 1000V / Basic Accuracy ±1.0% |
| Capacitance |
Range 1000µF / Basic Accuracy ±1.0% |
| Diode |
Range 1.5V / Basic Accuracy ±1.5% |
| Inrush AC Current |
Range 600.0A / Basic Accuracy ±3.0% |
| LoZ Mode AC Voltage |
Range: 60.00 V, 600.0 V, 1000 V Basic Accuracy: ±1.0% |
| LoZ Mode DC Voltage |
Range: 60.00 V, 600.0 V, 1000 V Basic Accuracy: ±1.0% |
| Resistance |
Range 6000Ω / Basic Accuracy ±1.0% |
| Temperature Accuracy |
± 3°C (5.4°F) or ±3% of rdg |
| Temperature Range |
14°F to 302°F (-10°C to 150°C) |
| VFD AC Current |
Range 600.0A / Basic Accuracy ±2.0% |
| VFD AC Voltage |
Range 1000V / Basic Accuracy ±1.0% |
| True RMS |
Yes |
| Continuity check threshold |
30Ω to 150Ω |
| Meter Data |
| Auto Power Off |
Yes |
| Auto Range |
Yes, with manual range option |
| Performance |
| Measuring Rate |
3 samples per second |
| Power |
| Battery |
3 AA batteries; optional TA04 Li-Poly rechargeable battery |
| Storage Media |
| Data Logging & Storage |
10 sets of 40K scalar measurements, 100 images |