Autonics SR2 Series General Specifications |
Dielectric strength (Vrms) |
• 24-240VAC~ rated load current 15A/30A: 2500VAC 50/60Hz 1 min (Input-Output, Input/Output-Case) |
• 24-240VAC~ rated load current 50A/75A
• 48-480VAC~ rated load current 15A/30A/40A/50A/75A : 4000VAC 50/60Hz 1 min (Input-Output, Input/Output-Case) |
Insulation resistance |
Over 100MΩ (at 500VDC megger) (Input-Output, Input/Output-Case) |
Indicator |
Input indicator: Green LED / Alarm output indicator: Red LED |
Vibration |
Mechanical |
0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour |
Malfunction |
0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min |
Shock |
Mechanical |
300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times |
Malfunction |
100m/s2 (approx. 30G) in each X, Y, Z direction for 3 times |
Environment |
Ambient temperature |
-30 to 80°C (in case of the rated input voltage 90-240VACᜠ: -30 to 70°C), Storage: -30 to 10°C℃ ( The rated load current capacity is different depending on ambient temperature. Refer to ' SSR Derating Curve'.) |
Ambient humidity |
45 to 85%RH, Storage: 45 to 85%RH |
Input terminal connection |
Min. 1×0.5mm2 (1×AWG 20) Max. 1×1.5mm2 (1×AWG 16) or 2×1.5mm2 (2×AWG 16) |
Output terminal connection |
Min. 1×1.5mm2 (1×AWG 16) Max. 1×16mm2 (1×AWG 6) or 2×6mm2 (2×AWG 10) |
Input terminal fixed torque |
0.75 to 0.95N·m |
Output terminal fixed torque |
1.6 to 2.2N·m |
Approval |
CE |
Weight*1 |
• Detachable heatsink type : approx. 365g (approx. 275g)
• Integrated heat sink type:
Rated load current 15A/30A/40A: approx. 896g (approx. 686g)
Rated load current 50A: approx. 1508g (approx. 1268g)
Rated load current 75A: approx. 2354g (approx. 2064g) |
*1: The weight includes packaging. The weight in parenthesis is for unit only.
*Environment resistance is rated at no freezing or condensation.
*For wiring the terminal, an O-ring terminal must be used. |