General Specifications |
Pressure type |
Gauge pressure (In case of fluid type, standard pressure are sealed gauge pressure※1 ) |
Type |
NPN or PNP open collector output type |
NPN or PNP open collector output+
analog output or external input type |
Model |
PSQ-XC01-X-X |
PSQ-XC1-X-X |
PSQ-XC01XU-X |
PSQ-XC1XU-X |
Rated pressure range |
-100.0 to 100.0kPa |
-100 to 1,000kPa |
-100.0 to 100.0kPa |
-100 to 1,000kPa |
Display&Setting pressure range |
-101.3 to 110.0kPa |
-101 to 1,100kPa |
-101.3 to 110.0kPa |
-101 to 1,100kPa |
Min. display unit |
0.1kPa |
1kPa |
0.1kPa |
1kPa |
Max. pressure range |
Pneumatic type |
2 times of rated pressure |
1.5 times of rated pressure |
2 times of rated pressure |
1.5 times of rated pressure |
Fluid type |
3 times of rated pressure |
Applied fluid |
- Pneumatic type: Air, Non-corrosive gas
- Fluid type: Air, Non-corrosive gas and fluid that do not corrode Stainless steel 316L
|
Power supply |
12-24VDC (ripple P-P: max. 10%) |
Allowable voltage range |
90 to 110% of rated voltage |
Current consumption |
Max. 50mA |
Max. 50mA (current output: max. 70mA) |
Control output |
NPN or PNP open collector output
Load voltage: Max. 30VDC *Load current: Max. 100mA Residual voltage: Max. 2VDC |
|
Hysteresis*2 |
Min. display interval |
|
Repeat error |
±0.2% F.S. ± Min. display interval |
|
Response time |
Select one; 2.5ms, 5ms, 10ms, 25ms, 50ms, 100ms, 250ms, 500ms, 1,000ms, 5,000ms |
|
Protection circuit |
Output short over current protection circuit |
Analog output*3 |
Voltage output |
--- |
Output voltage: 1-5VDC ±2.5% F.S.
Linear: Max. ±1% F.S.
Resolution: 1/2,000
Output impedance: Approx. 240Ω
Response time: 50ms |
Current output |
--- |
Output current: DC4-20mA ±2.5% F.S.
Linear: Max. ±1% F.S.
Resolution: 1/2,000
Output impedance: Approx. 100kΩ
Response time: 50ms |
External input*3 (Auto shift/ Remote zero/Hold) |
--- |
ON voltage: Max. 0.4VDC
OFF voltage: 5-Vin or open
Resolution: 1/2,000
Output impedance: Approx. 100kΩ |
Display digits |
Present value (PV) display part, Setting value (SV) display part: 4-digit |
Display method |
12-segment LCD method |
Min. display interval |
MPa |
0.001 |
0.001 |
0.001 |
0.001 |
kPa |
0.1 |
1 |
0.1 |
1 |
kgf/cm2 |
0.001 |
0.01 |
0.001 |
0.01 |
bar |
0.001 |
0.01 |
0.001 |
0.01 |
psi |
0.02 |
0.2 |
0.02 |
0.2 |
mmHg |
1 |
--- |
1 |
--- |
inHg |
0.1 |
--- |
0.1 |
--- |
mmH2O |
0.1 |
--- |
0.1 |
--- |
Display accuracy |
0 to 50℃: Max. ±0.5% F.S., -10 to 0℃: Max. ±1% F.S |
Insulation resistance |
Over 50MΩ (at 500VDC megger |
Dielectric strength |
1,000VAC 50/60Hz for 1min |
Vibration |
1.5mm amplitude at frequency of 10 to 55Hz (for 1min) in each X, Y, Z direction for 2 hours |
Environment |
Ambient temperature |
-10 to 50℃, storage: -20 to 60℃ |
Ambient Humidity |
30 to 80%RH, storage: 30 to 80%RH |
Cable (fluid type) |
Ø4mm, 5-wire, 3m (AWG24, core diameter: 0.08mm, number of cores: 40, insulator out diameter: Ø1mm) |
Protection structure |
Pneumatic type: IP40 (IEC standard) |
Fluid type: IP65 (IEC standard) |
Material |
Pneumatic type - Front case: Polycarbonate, Rear case: Polycarbonate, Pressure port: Brass-nickel plated
Fluid type - Front case: Polycarbonate, Rear case: Polyamide 6, Pressure port: Stainless steel 316L |
Approval |
CE |
Weight*4 |
Pneumatic type: Approx. 165g (approx. 80g) |
Fluid type: Approx. 210g (approx. 125g) |
*1: The unit is sealed structure. It is based on atmospheric pressure 101.3kPa.
*2: In hysteresis output mode, it is variable.
*3: Select one between analog output (voltage or current) and external input.
*4: The weight includes packaging. The weight in parenthesis is for unit only.
*Environment resistance is rated at no freezing or condensation. |