General Specifications |
Model |
Basic unit |
DS16-_S/T/D |
D_ 22- _S/P/T/D/R |
D_ 40-_ S/P/T/D/DT/R/RT |
D_ 60-_ S/P/T/D/DT/R/RT |
Expansion unit |
DS16-_E |
D_22-_E |
D_40-_E |
D_60-_E |
Input method |
D_-_-_-S: Serial |
D_-_-_-P: Parallel(Dynamic Parallel 1, Dynamic Parallel 2) |
D_-_-_-T: RS485 communication(Modbus protocol) |
DS_-RD/RDT: Temp./Humi. sensor module(THD-RM-S) input(I 2 C input type) |
DS_-RR/RRT: Pt temp. sensor input(supports DPt100Ω, JPt 100Ω) * 1 |
Display color*2 |
Red, Green(selectable by model) |
Power supply |
12-24VDC |
Allowable voltage range |
90 to 110% of rated voltage |
Current consumption |
Red |
D_-_-RS/RP/RT/RE |
Max. 20mA |
Max. 25mA |
Max. 55mA |
Max. 65mA |
D_-_RD/RDT/RR/RRT |
Max. 40mA |
Max. 40mA |
Max. 55mA |
Max. 65mA |
Gren |
Max. 15mA |
Max. 20mA |
Max. 40mA |
Max. 45mA |
Character size |
W9×H16mm |
W11.2×H22.5mm |
W22.4×H40mm |
W33.6×H60mm |
Max. Clock *3, *4 |
- Serial input: Max. 2kHz
- Parallel input: Dynamic Parallel 1: Max. 3kHz, Dynamic Parallel 2: Max. 1.5kHz
|
Input logic*3 |
20kΩ |
Input level*3 |
High: 4.5-24VDC, Low: 0-1.2VDC |
Display character*5 |
64 characters and signs(0 to 9, A to Z, 27 signs, decimal point) |
Display temp./humi. range |
DS_-RD/RDT temperature: -19.9 to 60.0 °C , humidity: 00.0 to 99.9%RH |
DS_-RR/RRT temperature: -50.0 to 400.0 °C or -58.0 to 752.0 °F |
Output |
--- |
RS485 com. output(Modbus RTU)*7 |
The number of max. multi-stange connections |
Serial/RS485 com. input: 24 units |
Parallel: Dynamic Parallel 1 : 6 units(4Bit), 4 units(6Bit)/ Dynamic Parallel 2 : 24 units(6Bit) |
Temp./Humi. sensor module input(+RS485 com. output): 6 units(3 units for temp. display, 3 units for humidity display, except unit-display unit) |
Pt temperature sensor input(+RS485 com. output): 4EA(except unit-display unit) |
Noise resistance |
±500V the square wave noise (pusel width: 1 ㎲ ) by the noise simulator |
Environment |
Ambient temperature |
-10 to 55 °C , storage: -25 to 65 °C (for THD-RM-S, -19.9 to 60 °C , storage: -19.9 to 60 °C ) |
Ambient humidity |
35 to 85%RH (for THD-RM-S, 0 to 99.9%, storage: 0 to 99.9%) |
Accessory |
Basic unit |
Cap: right/left 1EA |
Cap: right/left 1EA,
Connector : 1EA |
Connector: 1EA*8 |
Expansion unit |
---- |
Ribbon cable: 1EA(50mm) |
DS_-RD/RDT |
Temp./Humi. sensor module(THD-RM-S) |
Protection |
IP40 (front part) |
Approval*5 |
CE |
Weight |
D_-_-_S/P/T/R/RT |
Approx. 53g (approx. 12g)
|
Approx. 58g (approx. 17g) |
Approx. 70g (approx. 28g) |
Approx. 115g (approx. 60g) |
DS_-RD/RDT |
Approx. 168g (approx. 12g) |
Approx. 173g (approx. 17g) |
Approx. 184g (approx. 28g) |
Approx. 216g (approx. 60g) |
D_-_-_E |
Approx. 77g (approx. 12g)*10 |
Approx. 92g (approx. 17g)*10 |
Approx. 70g (approx. 28g) |
Approx. 115g (approx. 60g) |
*1: 16 size model does not support Pt temperature sensor input.
*2: Temp./Humi. sensor module input, Temp./Humi. sensor module input+RS485 com. output, Pt temp.
sensor input, Pt temp. sensor input+RS485 com. output models support only red display color.
*3: It is only for Serial, Parallel input models.
*4: Max. Clock is for 1:1 of duty ratio (ON, OFF ratio).
*5: It is only for Serial, Parallel, RS485 com. input models.
*6: Room temperature 23 °C ±5 °C
*7: RS485 com. output supports only DS40-R T, DS60-R T models.
*8: It is only for Parallel input model.
*9: The weight is with packaging and the weight in parentheses is only unit weight.
*10: This is 3 units' weight as packaging unit and the weight in parentheses is only unit weight.
*Environment resistance is rated at no freezing or condensation |