Autonics BW Series General Specifications |
Sensing type |
Through-beam |
Sensing distance |
0.1 to 7m |
Sensing target |
Opaque materials of Min.Ø30mm |
Opaque materials of Min.Ø50mm |
Optical axis pitch |
20mm |
40mm |
Number of optical axis |
8 to 48EA |
4 to 24EA |
Sensing width |
140 to 940mm |
120 to 920mm |
Power supply |
12-24VDC ±10%(Ripple P-P : Max. 10%) |
Reverse polarity protection |
Built-in |
Current consumption |
Emitter : Max. 80mA, Receiver : Max. 80mA |
Control output |
NPN or PNP open collector output
- Load voltage : Max. 30VDC
- Load current : Max. 100mA
- Residual voltage - NPN : Max. 1V, PNP : Min. 2.5V
|
Operation mode |
Light ON (fixed) |
Short-circuit protection |
Built-in |
Response time |
Max. 12ms |
Light source |
Infrared LED(850nm modulated) |
Synchronization type |
Synchronized by synchronous line |
Self-diagnosis |
Ambient light monitoring, Emitter/Receiver light circuit monitoring, Output circuit monitoring |
Interference protection |
Interference protection by master/slave function |
Environment |
Ambient illumination |
Sunlight : 10,000lx (received light side illumination) |
Ambient temperature |
-10 to 55°C, storage : -20 to 60°C |
Ambient humidity |
35 to 85%RH, storage : 35 to 85%RH |
Noise resistance |
±240V the square wave noise (pulse width: 1μs) by the noise simulation |
Dielectric strength |
1,000VAC 50/60Hz for 1minute |
Insulation resistance |
Min. 20MΩ(at 500VDC megger) |
Vibration |
1.5mm amplitude or 300m/s2 at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hour |
Shock |
500m/s2 (approx. 50G) in X, Y, Z directions for 3 times |
Protection |
IP65(IEC standard) |
Material |
• Case : Aluminum • Cover, Sensing part : Acrylic |
Cable |
Ø5, 4-core, length: 300mm, M12 connector |
Accessory |
Bracket A : 4EA, Bracket B : 4EA, Fixing bolt : 8EA |
Approval |
CE |
Unit weight |
Approx. 1.4kg(for 48 optical axises) |
*The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment. |