General Specifications |
Model |
ATE x S,M,H |
ATE1 x S,M,H |
ATE2 x S,M,H |
Function |
Power ON Delay |
Control time setting range |
sec.(1, 3, 6, 10, 30, 60), min.(3, 6, 10, 30, 60), hour(3, 6, 12 ,24) |
Power supply |
110/220VAC 50/60Hz |
110VAC, 220VAC 50/60Hz, 12VDC, 24VDC |
Allowable Voltage Range |
90 to 110% of rated voltage |
Power Consumption |
Max. 10VA (110/220VAC 50/60Hz), Max. 2W (24VDC, 12VDC) |
Reset time |
Max. 200ms |
Time operation |
Power ON Start Type |
Control output |
Contact type |
Time-limit SPDT (1c)+
Instantaneous SPST (1a) |
Time-limit DPDT (2c) |
Time-limit SPDT (1c)+
Instantaneous SPDT (1c) |
Contact capacity |
250VAC ~ 3A, 30VDC = 3A resistive load |
Relay life cycle |
Mechanical |
Min. 10,000,000 operations |
Electrical |
Min. 100,000 operations (250VAC 3A resistive load) |
Repeat error |
Max. ±0.3% |
Set error |
Max. ±5% ±0.05 sec |
Voltage error |
Max. ±0.5% |
Temp. error |
Max. ±2% |
Insulation resistance |
Over 100MΩ (at 500VDC megger) |
Dielectric strength |
2,000VAC 50/60Hz for 1min |
Noise immunity |
±2kV the square wave noise (pulse width 1 μ s) by noise simulator |
Vibration |
Mechanical |
0.75mm amplitude at frequency 10 to 55Hz (for 1min) in each X, Y, Z direction for 1 hour |
Malfunction |
0.5mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min |
Shock |
Mechanical |
300m/s 2 (approx. 30G) in each X, Y, Z direction for 3 times |
Malfunction |
100m/s 2 (approx. 10G) in each X, Y, Z direction for 3 times |
Environment |
Ambient temp |
-10 to 55 °C , storage: -25 to 65 °C |
Ambient humid. |
35 to 85%RH |
Weight |
Approx. 75g |