|
IR-710 |
IR-712 |
IR-720 |
IR-730 |
IR-750 |
Temperature Range |
0°F to 716°F
-18°C to 380°C |
0°F to 2022°F
-18°C to 550°C |
-26°F to 1922°F
-32°C to 1050°C |
-26°F to 2282°F
-32°C to 1250°C |
-58°F to 2822°F
-50°C to 1550°C |
Accuracy With ambient operating temperature of 70°F to 77°F (21°C to 25°C) |
18°C to 10°C (-0.4°F to 50°F °2%+1°C(2°F), or °3°C (°6°F), whichever is greater
>10°C to 380°C (>50°F to 716°F): °2%, or °2°C (°4°F), whichever is greater |
°1.8% or °4°F (°1.8°C), whichever is greater |
>0°C to 1250°C (>32°F to 2282°F): °1.8% or °1.8°C
(°4°F), whichever is greater
-32°C to 0°C (-26°F to 32°F): °1.8%+1°C (2°F) or °2.8°C
(°6°F), whichever is greater |
>0°C to 1550°C (>32°F to 2822°F): °1.8% or °1.8°C (°4°F), whichever is greater >-35°C to 0°C (-31°F to 32°F): °1.8%+1°C (2°F) or °2.8°C (°6°F), whichever is greater -50°C to -35°C (-58°F to -31°F): not specified (for reference only) |
Repeatability |
°0.5% of reading or °1°F (°0.5°C), whichever is greater |
Display Resolution |
0.1°F / 0.1°C |
0.1°F / 0.1°C of reading < 999.9 0.2°F / 0.2°C of reading below 10°C (50°F) 1°F / 1°C of reading > 999.9 |
Spectral Response |
8°m to14°m |
Laser Sighting |
Single point laser |
Laser Power |
Output > 1mW Class 2, wavelength 630 to 670nm |
Response Time (95%) |
500ms |
250ms |
Distance to Spot (D:S) |
10:1 |
12:1 |
20:1 |
30:1 |
50:1 |
Minimum Spot Size |
20mm |
25mm |
24mm |
19mm |
Emissivity |
0.95 |
Digitally adjustable from 0.10 to 1.00 by 0.01. Pre-set emissivity is 0.95 |
Ambient Operating Temperature |
32°F to 104°F
0°C to 40°C |
Relative Humidity |
0% to 75% non-condensing |
Storage Temperature |
-4°F to 150°F / -20°C to 65°C |
Temperature Display |
°F / °C selectable |
Display Hold |
8 seconds |
MAX/MIN
Temperature Display |
• |
• |
• |
• |
• |
DIF/AVG Temperature Display |
N/A |
• |
• |
• |
• |
Dual LCD Display |
• |
• |
• |
• |
• |
LCD Backlit |
• |
• |
• |
• |
• |
Low Battery Indication |
• |
• |
• |
• |
• |
Tripod mount |
N/A |
• |
• |
• |
• |
Power |
9V 6F22 alkaline battery or equivalent |
9V 6F22 alkaline battery or by power adaptor (output DC 6V/450mA) |
Battery Life |
10 hours with laser and backlight on
30 hours with laser and backlight off |
Dimension (H x L x W) |
Approx.153 x 108 x 40 mm
(6.0 x 4.5 x 1.6 in) |
Approx.169 x 138 x 53 mm
(6.7 x 5.4 x 2.1 in) |
Approx.183 x 147 x 57 mm
(7.2 x 5.8 x 2.3 in) |
Weight |
Approx.180 g (0.4 lb)
with battery installed |
Approx.290 g (0.64 lb)
with battery installed |
Approx.345 g (0.76 lb)
with battery installed |
Included Accessories |
Battery and Instruction Manual |
Carrying Bag, Battery and Instruction Manual
(Battery not installed) |
Software CD, USB Cable, K-type Thermocouple Probe, Carrying Bag, Hard Carrying Case, Battery and Instruction Manual |
Optional/ Recommended Accessories (IR-750 only) |
N/A |
Power adaptor EPS-700-US (US plug), EPS-700-EUR (European plug) |