Milliamp Source |
|
Ranges: |
0.00 to 24.000mA; -25.00 to 125.00% of 4 to 20mA; % DP Flow |
Accuracy: |
?(0.05% of 24 mA Span + 0.01 mA) = 0.02mA |
Typical Drive Capability: |
1200 Ohms @ 20.00 mA |
Compliance Voltage: |
Nominal 25 V @ 20 mA |
Power & Measure 2-wire Transmitters |
|
Ranges: |
0.00 to 24.000mA; -25.00 to 125.00% of 4 to 20mA; % DP Flow |
Accuracy: |
?(0.05% of 24 mA Span + 0.01 mA) = 0.02mA |
Output Current: |
Up to 24.00 mA |
Typical Drive Capability: |
1200 Ohms @ 20.00 mA |
Compliance Voltage: |
Nominal 25 VDC @ 20mA |
Common Mode Error: |
0.01% Full Scale/Common Mode Volt |
2-wire Transmitter Simulator |
|
Ranges: |
1.00 to 24.00mA; -18.8 to 125.0% of 4 to 20mA; % DP Flow |
Accuracy: |
?(0.05% of 24 mA Span + 0.01 mA) = 0.02mA |
Loop Voltage Limits: |
Minimum: 3 VDC
Maximum: 45 VDC |
Overload Protection: |
Current limited to 25 mA nominal |
Common Mode Error: |
0.01% Full Scale/Common Mode Volt |
Milliamps Read |
|
Ranges: |
0.000 to 24.000mA; -25.0 to 125.00% of 4-20mA; % DP Flow |
Accuracy: |
?(0.05% of 24 mA Span + 0.01 mA) = 0.02mA |
Overload Protection: |
Current limited to 25 mA nominal |
Voltage Burden: |
0.9V at 4 mA, 1.2V at 20 mA, 1.9V at 24 mA |
DC Voltage Source |
|
Ranges: |
0.000 to 110.000mV
0.00 to 10.25V |
Accuracy: |
?(0.05% of 110 mV+ 0.01mV) = ?0.07 mV
?(0.05% of 10.25 V + 0.01V) = ?0.02V |
Source Current: |
>20mA |
Sink Current: |
>20mA |
Output Impedance: |
Greater than 0.3 Ohms |
Short Circuit Duration: |
Infinite |
Measure AC Volts |
|
Ranges: |
0.0 to 250.0V True RMS |
Accuracy: |
From 10 to 250 VAC ?(2% of 250V + 0.1 VAC) = ?5.1VAC |
Maximum Crest Factor: |
Greater than 3 |
Frequency Range: |
45 to 800 Hz |
Measure DC Volts |
|
Ranges: |
0.0 to 110.0mV; 0.00 to 10.25; 0.0 to 200.0V |
Accuracy: |
?(0.05% of 110 mV+ 0.01mV) = ?0.07 mV
?(0.05% of 10.25 V + 0.01V) = ?0.02V
?(2% of 200.0 V + 0.1V) = ?4.1 V |
Input Resistance: |
> 1 Meg Ohm to 10.25V, > 5 Meg Ohm to 200V |
Source Resistance Effect: |
0.01% per 100 Ohms |
Source Thermocouples |
|
Thermocouple Types: |
J, K, T, E, N, R, & S |
Resolution: |
1?C or 1?F |
Accuracy: |
?C ?(0.05% OF 80 MV + 1?C)
?F ?(0.05% OF 80 MV + 1?F) |
Cold Junction Accuracy: |
?1?C |
Cold Junction Effect: |
within 0.05?C per ?C change |
Output Impedance: |
Greater than 0.3 Ohms |
Source Current: |
>10mA, Max |
Read Thermocouples |
|
Thermocouple Types: |
J, K, T, E, N, R, & S |
Resolution: |
0.1?C or 0.1?F |
Accuracy: |
?C ?(0.05% OF 80 MV + 1?C)
?F ?(0.05% OF 80 MV + 1?F) |
Cold Junction Accuracy: |
?1?C |
Cold Junction Effect: |
within 0.05?C per ?C change |
Input Impedance: |
> 1 Meg Ohm |
Open Thermocouple Detection: |
450 millisecond pulse
Nominal threshold, 10 K Ohms |
Read Ohms |
|
Range Ohms: |
0.0 to 1000.0 Ohms |
Accuracy: |
?(0.05% of 1000.0 Ohms + 0.1 Ohm) = ?0.6 Ohms |
Excitation Current Supplied: |
1 mA, nominal |
Continuity Checking |
|
Test Current: |
Nominal 1 mA |
Threshold: |
100 Ohm ?20% |
Indication: |
Steady tone & Symbol on LCD plus Ohm Reading |
Source RTD & Ohms |
|
RTD Types: |
Pt 100 Ohm for 1.3850 (DIN/IEC 751 & New JIS), 1.3902 (Burns), 1.3926 (US Lab) & 1.3916 (Old JIS 1604C-1981) |
RTD Resolution: |
1?C or 1?F |
Range Ohms: |
0.0 to 400.0 Ohms |
Accuracy: |
?0.05% of Full Scale + 0.075 mV/mA Excitation Current |
Accuracy Ohms: |
?(0.05% of 400.0 Ohms + 0.1 Ohm = ?0.3 Ohms (At 1 mA Excitation Current) |
Temperature Effect: |
?((0.035mV/?C)*(1/mAExcitation Current)) |
Allowable Excitation Current: |
0.125 to 2.0 mA continuous DC |
Read RTD |
|
RTD Types: |
Pt 100 Ohm for 1.3850 (DIN/IEC 751 & New JIS), 1.3902 (Burns), 1.3926 (US Lab) & 1.3916 (Old JIS 1604C-1981) |
RTD Resolution: |
1?C or 1?F |
RTD Range (Ohms): |
0.0 to 400.0 Ohms |
RTD Accuracy: |
?(0.05% of 400.0 Ohms + 0.1 Ohm = ?0.3 Ohms |
Excitation Current Supplied: |
1 mA, nominal |
Frequency Source |
|
Ranges: |
1 to 1500 CPM (Count-Per-Minute); 1 to 1500 Hz, 0.01 to 15.00 kHz |
Accuracy: |
?(0.05% of 1500 CPM + 1 CPM) = ?2 CPM
?(0.05% of 1500 Hz + 1 Hz) = ?2 Hz
?(0.05% of 15.00 kHz + 0.01 kHz) = ?0.02 kHz |
Output Waveform: |
Square Wave, Zero Crossing, -1V to +5V?10% |
Risetime: |
Hz greater than 5 microseconds; CPM greater than 100 microseconds |
Output Impedance: |
Greater than 100 Ohms |
Source Current: |
> 1 mA at 10 kHz |
Short Circuit Duration: |
Infinite |
Measure Frequency |
|
Ranges: |
1 to 1500 CPM (Count-Per-Minute); 1 to 1500 Hz, 0.01 to 15.00 kHz |
Accuracy: |
?(0.05% of 1500 CPM + 1 CPM) = ?2 CPM
?(0.05% of 1500 Hz + 1 Hz) = ?2 Hz
?(0.05% of 15.00 kHz + 0.01 kHz) = ?0.02 kHz |
Trigger Level: |
1 V RMS, DC coupled to 10.25V
7 V RMS, DC coupled to 250 V |
Input Impedance: |
> 1 Meg Ohm + 60pF |
General |
|
Typical 90 day Accuracy: |
?(0.025% of Full Scale + 1 LSD) |
1 Year Accuracy: |
?(0.05% of Full Scale + 1 LSD) |
Warm up Time: |
10 Seconds to specified accuracy, 2 minutes to maximum accuracy |
Temperature Effect: |
?0.01%/?C based on 23?C ?25?C |
Batteries: |
Six "AA" (R6) batteries (Alkaline supplied and recommended) |
Battery Life: |
Milliamp Source and 2-wire Modes: Nominal 12 hours at 12 mA, 20 hours at 20 mA with 250 ohm load
Other Functions: Nominal 50 hours |
Low Battery Indication: |
"BAT" indication on the display, approximately 4 hours left |
Overload Protection: |
Three fuses, 125 mA |
Noise: |
?1 LSD at frequencies less than 10 Hz |
Normal Mode Rejection Ratio: |
50dB @ 50/60 Hz |
Operating Temperature Range: |
-5 to +130 ?F (-20 to +55?C) |
Storage Temperature Range: |
-13 to +130 ?F (-25 to +55?C) |
Relative Humidity: |
10 to 90%, non-condensing for 24 hours |
Dimensions: |
158.1mm (6.23 in) x 83.1mm (3.27 in) x 49.3mm (1.94 in) |
Weight: |
1lb 5oz (0.6kg) |