Milliamp Source |
|
Ranges: |
0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20 mA |
Accuracy: |
Quik-Chek 4mA ±(0.03% of 4mA + 0.01 mA) = 0.011mA
Quik-Chek 20mA ±(0.03% of 20mA + 0.01 mA) = 0.016mA
0 to 24mA ±(0.05% of Reading + 1 LSD) |
Typical Drive Capability: |
1200 Ohms @ 20.00 mA with fresh batteries, 800 Ohms @ 20.00 mA with low batteries |
Compliance: |
Nominal 27 VDC @ 20 mA with fresh batteries |
Power & Measure 2-wire Transmitters |
|
Ranges: |
0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20 mA |
Accuracy: |
Quik-Chek 4mA ±(0.03% of 4mA + 0.01 mA) = 0.011mA
Quik-Chek 20mA ±(0.03% of 20mA + 0.01 mA) = 0.016mA
0 to 24mA ±(0.05% of Reading + 1 LSD) |
Output Current: |
Up to 24.00 mA |
Typical Drive Capability: |
1200 Ohms @ 20.00 mA with fresh batteries, 800 Ohms @ 20.00 mA with low batteries |
Compliance: |
Nominal 27 VDC @ 20 mA with fresh batteries |
2-wire Transmitter Simulator |
|
Ranges: |
0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20 mA |
Accuracy: |
Quik-Chek 4mA ±(0.03% of 4mA + 0.01 mA) = 0.011mA
Quik-Chek 20mA ±(0.03% of 20mA + 0.01 mA) = 0.016mA
0 to 24mA ±(0.05% of Reading + 1 LSD) |
Loop Voltage Limits: |
Minimum: 2 VDC
Maximum: 100 VDC |
Overload Protection: |
Current limited to 25 mA nominal |
Milliamp Read |
|
Ranges: |
0.00 to 52.00 mA; -25.0 to 300.0 % of 4 to 20 mA |
Accuracy: |
Quik-Chek 4mA ±(0.03% of 4mA + 0.01 mA) = 0.011mA
Quik-Chek 20mA ±(0.03% of 20mA + 0.01 mA) = 0.016mA
0 to 24mA ±(0.05% of Reading + 1 LSD) |
Voltage Burden: |
0.9V at 4 mA, 1.2V at 20 mA, 1.9V at 50 mA excitation current |
Read DC Volts |
|
Range: |
-99.99 to 99.99V DC |
Input Impedance: |
>2 Meg Ohms |
General |
|
Accuracy: |
Quik-Chek 4 & 20 mA ±(0.03% of Setting + 1 LSD)
Milliamp & % Ranges ±(0.05% of Reading + 1 LSD)
Read DC Volts ±(0.05% of Span + 1 LSD) |
Warm up Time: |
10 Seconds to specified accuracy, 2 minutes to maximum accuracy |
Temperature Effect: |
Milliamp Ranges: ±0.008% of Reading/°C
Read DC Volts: ±0.012% of Span/°C |
Batteries: |
Three 9V, (1604) batteries (Alkaline supplied and recommended) |
Battery Life: |
Source and Power Transmitter: Nominal 33 hours at 12 mA, 20 hours at 20 mA with 250 ohm load
Read mA, DC V & 2-wire Simulate: Nominal 100 hours |
Low Battery Indication: |
"BAT" indication on the display at approximately 4 hours left |
Overvoltage Protection: |
Protected to 135V AC/DC for 30 seconds without fuses |
Operating Temperature Range: |
-5 to +140 °F (-20 to +60°C) |
Storage Temperature Range: |
-22 to +160 °F (-30 to +70°C) |
Relative Humidity: |
10 to 90%, non-condensing for 24 hours from 0 to 35°C |
Dimensions: |
121.9mm (4.8 in) x 66mm (2.6 in) x 35.8mm (1.41 in) |
Weight: |
7.8oz (0.22kg) |