Specificationsa |
Model: FS200-# |
-303 |
OTDR |
Emitter Type |
Laser |
Safety Classb |
Class I |
Fiber Type |
Single-mode |
Wavelengths (nm) |
1310/1550/1625 |
Center λ Tolerancec |
1310/1550/1650: ± 20 nm; 1625 +30/-5 nm |
Dynamic Ranged (dB) |
37/36/37 |
Event Dead Zonee (m) |
0.8 |
Atten. Dead Zonef (m) |
3.5 |
PON Dead Zoneg (m) |
25/25/30 |
Pulse Widths |
3, 5, 10, 20, 30, 50, 100, 200, 300, 500 ns;
1, 2, 3, 10 µs; 20 µs (FS200-300/300/304 only) |
Range Settings |
250 m to 240 km |
Data Points |
Up to 300,000 (Expert mode .SOR file) |
Data Spacing |
5 cm to 16 m |
Group Index of Refraction |
1.3000 to 1.7000 |
Distance Uncertainty (m) |
±(1 + 0.003% x distance + data point spacing) |
Linearity (dB/dB) |
±0.05 |
Trace File Format |
Telcordia SR-4731 Issue 2 compatible .SOR |
Trace Storage Medium |
4 GB internal memory (>5000 traces typical);
External USB memory stick |
Data Transfer to PC |
USB cable or Bluetooth® (option) |
Standard OTDR Modes |
SmartAuto, Expert, Real Time |
FleXpress Fast Test |
FS200-300/303/304 |
Display Modes |
LinkMap Summary, LinkMap Events, Trace |
Refresh Rate |
Up to 4 Hz (Real-time mode) |
Live Fiber Protection |
No OTDR damage with input power ≤ +15 dBm for wavelength(s) in range 1260 to 1675 nm |
Live Fiber Detection |
Reports live fiber with input signal ≥ -35 dBm for wavelength(s) in range 1260 to 1675 nm |
PON Filter Isolation |
>50 dB for 1260 nm ≤ wavelength ≤1600 nm |
Live PON OTDR Test |
1625 or 1650 nm using filtered detector |
VISUAL FAULT LOCATOR (VFL) |
Emitter Type |
Visible red laser, 650 ±20 nm |
Safety Classb |
Class II |