Specifications |
Model: FS200-# |
-300 |
OTDR |
Emitter Type |
Laser |
Safety Classb |
Class I |
Fiber Type |
Single-mode |
Wavelengths (nm) |
1310/1550 |
Center λ Tolerance |
±20 nm (CW mode) |
Dynamic Range (dB)c |
37/36 |
Event Dead Zoned (m) |
0.8 |
Atten. Dead Zonee (m) |
3.5 |
PON Dead Zonef (m) |
25/25 |
Pulse Widths |
3, 5, 10, 20, 30, 50, 100, 200, 300, 500 ns;
1, 2, 3, 10 µs; 20 µs (FS200-60/300/304 only) |
Range Settings |
250 m to 240 km |
Data Points |
Up to 300,000 (Expert mode .SOR file) |
Data Spacing |
5 cm to 16 m |
Group Index of Refraction |
1.3000 to 1.7000 |
Distance Uncertainty (m) |
±(1 + 0.003% x distance + data point spacing) |
Linearity (dB/dB) |
±0.05 |
Trace File Format |
Telcordia SR-4731 Issue 2 compatible .SOR |
Trace File Storage Medium |
4 GB internal memory (>5000 traces typical);
External USB memory stick |
Data Transfer to PC |
USB cable or Bluetooth® or WiFi (option) |
Standard OTDR Modes |
SmartAuto, Expert, Real Time |
Display Modes |
LinkMap Summary, LinkMap Events, Trace |
FleXpress Fast Test |
Yes |
Real-time Refresh Rate |
Up to 4 Hz |
Live Fiber Protection |
No OTDR damage with input power ≤ +15 dBm for wavelength(s) in range 1260 to 1675 nm |
Live Fiber Detection |
Reports live fiber with input signal ≥ -35 dBm for wavelength(s) in range 1260 to 1675 nm |
Live PON Filter Isolation |
>50 dB for wavelength(s) in range 1260 to 1600 nm |
Live PON OTDR Test |
1650 nm using filtered detector |
VISUAL FAULT LOCATOR (VFL) |
Emitter Type |
Visible red laser, 650 ±20 nm |
Safety Classb |
Class II |
Output Power (nominal) |
0.8 mW into single-mode fiber |
Modes |
CW, 2 Hz flashing |