Electrical Specifications |
Operating Range |
0.2 to 600A |
Operating Range |
RangeVal |
60A / 600A |
Current Range |
0.2 to 40AAC (60A Peak); 0.4 to 60ADC, 0.5 to 400AAC (600A Peak); 0.5 to 600ADC |
Frequency Range |
DC to 10kHz at -3dB |
Common Mode Voltage |
600VAC |
Current Overload |
2000ADC and 1000AAC continuous up to 1kHz |
Insertion Impedance |
0.39mW @ 50Hz, 58mW @ 1000Hz |
Load Impedance |
> 100kW/100pF |
Overload Indication |
Red LED indicates input > selected range |
Reference Conditions |
18° to 28°C, 20 to 75% RH, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered, 1MW £100pF load, zero adjustment prior to measurement [DC only] DC to 65Hz, battery voltage 9V ±0.1V |
Working Voltage |
600VAC |
Influence of Adjacent Conductor |
Range Value |
50Hz at 23 mm from the probe |
Influence of Adjacent Conductor |
< 10mA/A |
Influence of Conductor Position |
Influence of Conductor Position |
0.5% Reading (DC to 440Hz) |
Influence of Humidity |
Influence of Humidity |
10 to 90%: £0.5% |
Rise Fall Time |
Range Value |
60A, 600A |
Rise Time |
£100µs froµ 10 to 90% Vout, £70µs froµ 10 to 90% Vout |
Noise |
Current Range |
60A, 600A |
Range Value |
DC to 1kHz, DC to 5kHz, 0.1Hz to 5kHz, DC to 1kHz, DC to 5kHz, 0.1Hz to 5kHz |
Noise |
£8mV or 0.8A (peak to peak), £12mV or 1.2A (peak to peak), £2mV or 0.2A (peak to peak), £1mV or 1A (peak to peak), £1.5mV or 1.5A (peak to peak), £500µV or 0.5A (peak to peak) |
Output Signal |
Range Value |
40A, 400A |
Output Signal |
10mV/A, 1mV/A |
Phase |
Range |
60A, 600A |
Range Value |
45 to 65Hz |
Current Range Value |
10 to 20A, 20 to 40A, 10 to 100A, 100 to 400A |
Phase Shift |
£3°, £2°, £1.5° |
Mechanical Specifications |
Altitude |
Operating: 0 to 2000m; Non-operating: 0 to 12km |
Auto Off |
10 minutes (may be disabled at power-up by pressing Zero button on; green LED blinks three times to indicate auto-off is disabled |
Battery Life |
Approximately 50 hours with alkaline battery |
Colors |
Dark gray handles with red jaws |
Dimensions |
8.8 x 3.82 x 1.73" (224 x 97 x 44mm) |
Drop Test |
1.0m on 38mm of oak on concrete; (IEC 68-2-32) |
Jaw Opening |
1.2" (31mm) |
Low Battery |
Green LED on when battery voltage ³6.5V |
Material |
Jaws: Polycarbonate with 10% fiberglass charge, Red UL 94 V0; Case: Polycarbonate |
Maximum Bus Bar Size |
Two bus bars 1.2 x 0.39" (31.5 x 10mm) |
Maximum Cable Diameter |
One 1.18" (30mm) or two 0.95"; (24mm) |
Mechanical Shock |
100g per IEC 68-2-27 |
Operating Temperature |
14° to 131°F (-10° to 55°C) |
Operating Relative Humidity |
10-35°C 90 ±5% RH (without condensation); 40-55°C 70 ±5% RH (without condensation) |
Output |
Double insulated 5 ft (1.5m) lead with safety banana plugs |
Power Supply |
9V Alkaline (NEDA 1604A, IEC 6LR61) |
Protection Index (IP) |
IP30 (IEC 529) |
Impact Test |
IK04 0.5 J EN50102 |
Storage Temperature |
-40° to 176°F (-40° to 80°C) |
Vibration |
Test per IEC 68-2-6 |
Vibration |
Range Value |
5 to 15Hz, 15 to 25Hz, 25 to 55Hz |
Vibration |
Amplitude: 1.5 mm per IEC 68-2-6, Amplitude: 1 mm per IEC 68-2-6 Amplitude : 0.25 mm per IEC 68-2-6 |
Weight |
15 oz (440g) |
Zero Adjustment |
Automatic zero ± 10A by simple push button |
External Influences |
Influence of Temperature |
£300 ppm/°K or 0.3% /10K° |
Safety Reference Specifications |
Safety Ratings |
EN 61010-2-32 |
Agency Approvals |
CE Mark |