| Bandwidth | 40 MHz |
Real time sample rate 2 channels interleaved | 500 MSa/s |
| Equivalent sample rate | 50 GSa/s |
| Rise time | < 8.8ns |
| Channels | 2 |
| Lower frequency limit | < 5Hz (at input BNC) |
| Display | Color LCD, 5.7 inch (145mm) diagonal |
| Record Length* | 4000 points |
| Vertical Resolution | 8 bit |
| Vertical Sensitivity | 2mV - 5V/div |
| DC gain accuracy | ±3.0% |
| Maximum Input Voltage | 300 Vrms, CAT II (between signal and reference BNC connector) |
| Position Range | 2mV - 100mV range: ±2V 200mV - 5V range: ±40V |
| Time Base Range | 10 ns/div - 50 s/div |
| Bandwidth Limit | 20 MHz |
| Time Base Accuracy | 100 ppm |
| Input Coupling | AC, DC, GND |
| Input Impedance | 1MOhm || 13pF |
| Vertical and Horizontal Zoom | Vertically or horizontally expand or compress a live or stopped waveform |
| I/O interface | USB device port for connection to PC. (Requires included EasyScope Software for use) |
| * The instrument displays 2500 points. 4000 points can be retrieved from internal memory with the included EasyScope application. This feature is supported for time base settings ranging from 2.5µs/Div - 50ms/Div (scan mode not active) |
| Sample | Display sample data only |
| Average | Waveform averaged, selectable from 4, 16, 32, 64, 128, 256 |
| Scan Mode | For time base settings 0.1s/div - 50s/div |
| Trigger Types | Edge, Pulse Width, Video |
| Trigger Modes | Auto, Normal, Single |
| Trigger Coupling | AC, DC, LF reject, HF reject |
| Trigger Source | CH1, CH2, AC line, Ext, Ext/5 |
| Holdoff range | 100ns - 1.5s |
| Trigger Level Range | | CH1, CH2 | ±12 divisions from center of screen | | EXT | ±2.4V | | EXT/5 | ±12V | |
| Pulse Width Trigger | | Pulse Width Range | 20ns - 10s | | Trigger Condition | (>, <, =) positive Pulse (>, <, =) negative Pulse | |
| Edge Trigger | | Trigger Polarity | Rising and Falling Edge | |
| Video | Supports formats PAL/SECAM, NTSC. Triggers on odd or even field, all lines or line number |
| Types | Amplitude, Time |
| Measurements | V, T, 1/T |
| Time | Rise time, Fall Time, Cycle Frequency, Period, Positive Pulse width, Negative Pulse width |
| Voltage | MAX, MIN, Peak-Peak, Average, Vrms |
| Frequency | | Hardware counter providing frequency readout of trigger source | | Readout resolution | 6 digits | | Range | 10Hz to max Bandwidth (DC Coupling) | | Supported signal types | all trigger modes except pulse width trigger and Video Trigger | |
| Math functions | FFT, add, subtract, multiply, divide |
| FFT | | FFT Windows | Hanning, Hamming, Blackman, Rectangular | | Sample size | 1024 points | |
| Single button automatic setup of both channels for vertical, horizontal and trigger systems |
| Bandwidth | 40 MHz |
| Phase Error | ±3.0 degrees |
| Display Mode | 1/4 VGA (320 × 240) Color LCD with adjustable contrast and inverse video |
| Display types | Point, Vector |
| Persistence | Off, 1s, 2s, 5s, infinite |
| Waveform interpolation | Sin(x)/x, Linear |
| Format | YT and XY |
| Input Voltage | 100 - 240 VAC, CAT II, Auto selection |
| Frequency | 45Hz to 440Hz |
| Power | 50VA Max |
| Dimensions | 290mm (W) × 150mm (H) × 300mm (D) 11.4in (W) × 5.9in (H) × 11.8in (D) |
| Weight | 4.6 kg (10 lbs) |
| Temperature | Operating: 0°C to +55°C Nonoperating: -40°C to +70°C |
| Humidity | Operating: 95%RH, 40°C Nonoperating: 90%RH, 65°C |
| Altitude | Operating to 4000m |
| Pollution Degree | Pollution degree 2 for indoor use only. |
| EMC | This oscilloscope is in compliance with council EMC directive 2004/108/EC |
| Safety | EN61010-1:2001 |
| Supplied | User Manual, passive probe set (2 pieces), Power cord, USB interface cable, EasyScope Software Installation disk |
| Optional | PR 37A 10:1 Probe, PR 32A Demodulator Probe, PR 55 High Voltage Probe |