Medical Device Safety Testers

 
Instek GLC-9000 Leakage Current Tester
  • Test Method (Safety): IEC 60601-1, IEC 60990
  • Test Type Hipot: AC, DC
  • Max Trip Current DC Test: 25 mA
  • Min Trip Current DC Test: 50 uA (0.05 mAWhat's This?)
  • Programmable (hipot): Yes
  • Maximum Current AC: 75 mA (0.075 AWhat's This?)

List Price: $2,329.00

Your Price: $2,212.55

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Hioki ST5540 Leak Current HiTester Medical IEC Standard
  • Test Method (Safety): IEC 60601-1, JIS T 0601-1
  • Maximum Current AC: 75 mA (0.075 AWhat's This?)
  • Maximum Current DC: 50 mA (0.05 AWhat's This?)
  • Minimum Current AC: 50 uA (0.05 mAWhat's This?)
  • Minimum Current DC: 50 uA (0.05 mAWhat's This?)
  • Unique Features: Designed for testing medical electrical equipment

Your Price: $4,389.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Hioki 3157-01 AC Grounding HiTester
  • Test Method (Safety): IEC 60065, IEC 60204-1, IEC 60335-1, IEC 60601-1, IEC 60950-1, IEC 61010-1
  • Maximum Test Current: 31 A
  • Resolution AC Current: 0.1 A
  • Adjustable Test Current (Ground Bond): Yes
  • Programmable: Yes
  • Display Type: Digital

Your Price: $3,355.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Hioki ST5541 Leak Current HiTester JIS, UL IEC Standard
  • Test Method (Safety): IEC 60065, IEC 60950-1, IEC 60990, IEC 61010-1, JIS B8561, JIS C9250, uL 1492, uL 2231-1, uL 2231-2, uL 492
  • Maximum Current AC: 75 mA (0.075 AWhat's This?)
  • Maximum Current DC: 50 mA (0.05 AWhat's This?)
  • Minimum Current AC: 50 uA (0.05 mAWhat's This?)
  • Minimum Current DC: 50 uA (0.05 mAWhat's This?)
  • Accuracy: DC measurement: 2.0% rdg. 6 dgt. (typ.)
    AC / AC+DC measurement: 2.0% rdg. 6 dgt. (15 Hz to 100 kHz, typ.)
    AC peak measurement: 2.0% rdg. 6 dgt. (15 Hz to 10 kHz, typ.)

Your Price: $3,179.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Compliance Biphasic P 360J Biphasic Waveform Tester
Catalog: 00-MPBiphasic P 360J
  • Test Method (Safety): N/A
  • Test Type Hipot: N/A
  • Max AC Test Voltage: N/A
  • Max DC Test Voltage: N/A
  • Min AC Test Voltage: N/A
  • Min DC Test Voltage: N/A
Call Us
null
null
null
null
null

Recommended for you

Medical Device Safety Testers

Medical Device Safety Testers are a class of Electrical Safety Testing and Surge Testing Equipment designed to test Medical Devices for operator and patient use. They include Hipots, Ground Bond Testers, and Leakage Current Testers, and multifunction instruments that can perform more than one test. Medical Device Safety Testers are used by equipment manufacturers, those doing repairs, and others to meet specific medical device safety standards.

Learn more about the tests and test methods in our Safety Tester Buyer's Guide and checkout this Medical Device Safety Tester department for our wide selection of models.

Electrical Safety Test Methods for Equipment

There are global standards to test for electrical safety of medical devices. For example, IEC 60990 Standard discusses the safety involving the flow of leakage or touch current through the human body. The effect of electric current on a human body can be extremely dangerous. It provides measuring methods for the four body responses:

• Perception
• Reaction
• Let-Go
• Electric Burn

JIS T 0601-1 is the Japanese modification of the existing IEC 60601-1 Safety Standard. IEC 60601-1 is the accepted standard for safety testing of all medical equipment. Both consider safety to be the primary concern.

Here are more standards to consider. Note: It is a partial list. Also, if a test instrument we offer does not specifically list a particular test method, that does not necessarily mean it cannot be used. Since there are so many test methods, the litereture may not enumerate them all. Please contact us with the specific method and we can research it for you.

Partial List of Global Electrical Safety Standards for Medical Devices
ANSI / AAMI EC11 Diagnostic Electrocardiographic Devices U.S.
ANSI / AAMI EC13 Cardiac Monitors, Heart Rate Meters, and Alarms U.S.
ANSI / AAMI EC53 ECG Cables and Leadwires U.S.
DIN VDE 0701-0702 0701 Repair, Modification, and Inspection of Electrical Equipment. 0702 Periodic Testing of Electrical Equipment German
IEC 60601-1 Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance Europe
IEC 60601-2 Medical Electrical Equipment - Part 2: Particular Requirements for the Basic Safety and Essential Performance of Gamma Beam Therapy Equipment Europe
IEC 60990 Methods of Measurement of Touch Current and Protective Conductor Current Europe
IEC 61010-1 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Europe
IEC 62052-11 Electricity Metering Equipment (AC) - General Requirements, Tests, and Test Conditions Europe
IEC 62353 Medical Electrical Equipment - Recurrent Test and Test After Repair of Medical Electrical Equipment Europe
JIS T 0601-1 Electrical Safety Standard for Medical Devices Japan



X