Signal Conditioning

 

Your Price: $197.91

In Stock:
  • View Payment Options

Your Price: $154.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Autonics SCM-US48I - Communication Converter Module ( RS485 - USB convertible)
  • HTS/Schedule B Number: 9030.31.0000
  • ECCN Number: EAR99
  • Country of Origin: Korea

Your Price: $154.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options

Your Price: $154.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options

Your Price: $244.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options

Your Price: $364.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Enerpac SLR1 - SafeLink Wireless Communication, RECEIVE Unit w/ External Antenna
  • Warranty Details: Warranted for so long as it is owned by the first-using purchaser.
  • Safety Approval: FCC
  • Interfaces I/O: LAN / Ethernet, RS-485
  • IP Rating: IP67
  • Shipping Weight: 1.40 LBS
  • Power Supply Voltage: Battery Powered

Your Price: $1,525.00

In Stock:
Enerpac SLS1 - SEND Unit w/Internal Antenna, SafeLink Wireless Communication
  • Warranty Details: Warranted for so long as it is owned by the first-using purchaser.
  • Shipping Weight: 1.25 LBS
  • Power Supply Voltage: Battery Powered

Your Price: $1,191.00

In Stock:
Enerpac SLS2 - SEND Unit w/External Antenna, SafeLink Wireless Communication
  • Warranty Details: Warranted for so long as it is owned by the first-using purchaser.
  • Shipping Weight: 1.20 LBS
  • Power Supply Voltage: Battery Powered

Your Price: $1,238.00

In Stock:
Enerpac SLS3 - SEND Unit with External Antenna, 3 Inputs
  • # of Inputs (Signal Conditioning): 3
  • Power (Signal Conditioning): DC
  • IP Rating: IP67
  • Shipping Weight: 0.70 LBS

Your Price: $1,238.00

In Stock:
Comet ZbC2+ - Zener Barrier
  • Enclosure Type (Signal Conditioning): Hazardous Area Approval
  • Warranty: 3 YEARS

Your Price: $396.00

Sign-in for EDU Pricing!

In Stock:
Autonics CN-6000 Signal Transmitters / Converters / Preamps - Type (Signal Conditioning): mV Transmitter, # of Inputs (Signal Conditioning): 1, Isolated Inputs (Process): Yes
  • Type (Signal Conditioning): Converter - 1 Input to 2 Outputs (Analog), Converter - mA to DC Volts / DC Volts to mA, Converter - Square Root, Frequency Transmitter (Pulse to mA), Isolator, mV Transmitter
  • # of Inputs (Signal Conditioning): 1
  • Isolated Inputs (Process): Yes
  • Output Types (Signal Conditioning): 4-20 mA, Relay
  • Power (Signal Conditioning): AC, DC
  • Unique Features: Model CN-610x-x Has unique feature. Can handle compound pressure range -760 mmHg to 3 Kg/cm2 with 0 = atmospheric pressure
From: $189.95 - $285.95
  • Free shipping over $99 - Code: FREESHIP
  • In Stock:

    Customize the item below to add to cart.

    null
    null
    null
    null
    null
    null
    null
    null
    null
    null
    null
    null

    Recommended for you

    Signal Conditioning

    Signal Conditioners are used to amplify sensor signals and correct for problems such as ground loops. Signal conditioners is a broad category that includes several different types of devices: signal conditioners, signal converters, signal transmitters, signal alarm modules, signal isolators, amplifiers, and preamplifiers.

    Field temperature and pressure transmitters are in a different department. Visit Process Measurement to purchase.

    Some manufacturers of sensors will have an option for a signal conditioner built into or for remote mounting. However, in other cases, there is a need for an external signal conditioner or converter to provide the desired output signal, more attractive price, or better specifications.

    Signal conditioners are ancillary devices intended to amplify, filter, condition, scale into engineering units, linearize, and convert raw signals produced by transducers and convert it to an industry standard signal such as 0-10 VDC or 4-20 mA. These raw signals are usually very low voltage and susceptible to picking up electrical noise from surrounding equipment and power lines. Conditioned signals are better able to be transmitted longer distances and through electrically noisy environments. Another function may be to also provide signal isolation, i.e. signal isolators.

    Generally, the output signals from the sensor may be in the form of either a pulse or analog current / voltage that is proportional to the span of the signal being measured. Open collector transistors are common as pulse output signals.

    The most common analog signal is a 4-20mA. In many flowmeter types the frequency of the raw input signal carries the flow information. The frequency is related to flow rate. Each pulse or cycle is related to a small equivalent quantity of flow. The quantity represented by each pulse varies with each individual meter and must be scaled to obtain engineering units. The input signal to a pulse signal conditioner may be a contact closure, a magnetic pickup, or a low level pulse. Some conditioner/converters scale the pulse signal such that each pulse represents a engineering quantity of flow (for example 1 pulse per gallon). Some converters convert the variable frequency signal into a current proportional to flow rate.

    In nearly all cases the signal conditioner is intended to be powered by a DC supply voltage normally available in most instruments with 24 VDC being the most common. Signal conditioners are typically without a display and for mounting inside an enclosure rated for the environment. DIN rail type being the most common mounting style.
     
    signal conditioner application example
    Signal Conditioner Application Example