MEGGER MIT1525
Test Voltages 250 V, 500 V, 1000 V, 2500 V, 5000 V
Resistance Range 10KΩ to 15TΩ
Enclosure Sealing IP65 (lid closed); IP40
Internal Memory Capture 5.5hr of data @ 5s intervals (more than 1,000 tests)
Guard Terminal Yes
Insulation Test Voltage Accuracy +4%
Battery Li-Ion 11.1V, 5.2Ah rechargeable 6hrs continuous testing
Altitude 3000m
FLUKE 1550C
Test Voltages 250 V, 500 V, 1000 V, 2500 V, 5000 V
Resistance Range Up to 2TΩ
Enclosure Sealing IP40
Internal Memory 99 memory locations
Guard Terminal Yes
Insulation Test Voltage Accuracy +10%
Battery 12V lead-acid rechargeable
Altitude 2000m

Comparison Summary

The Megger MIT525 and Fluke 1550C are powerful insulation resistance testers capable of tesing at voltages up to 5kV. Both units are capable of generating the same test voltages and each unit is about the same price. The major differences between these two units come when you dig deeper into the details.

The Megger MIT525 has a larger resistance range than the Fluke 1550C as well as better enclosure sealing, a better battery, larger internal memory, and greater test voltage accuracy. While the Fluke 1550C lags behind in these areas, it does include Fluke's unique Fluke Connect® technology which allows you to configure, start and stop tests remotely. With Fluke Connect® you can also save test results to the cloud and easily create reports using Fluke Connect desktop.

Want to know more? Check out the tables below for complete specifications or give us a call at 877-571-7901. We’re happy to answer any questions you may have.

Learn More about the MEGGER MIT1525 Learn More about the FLUKE 1550C
ModelFluke 1550CMegger MIT525
ProductFluke 1550C Megohmmeter/Insulation Resistance Tester, 5kV, > 2 teraohmInsulation Tester 5kV IRT, IR, IR(t), DAR, PI, DD, SV, Ramp, USB, Battery and Line...
Rating(2)(3)
Price
In Stock

Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers

IR Test Voltage1,000 V, 2,500 V, 250 V, 5,000 V, 500 V1,000 V, 2,500 V, 250 V, 5,000 V, 500 V 
Maximum Insulation Resistance2 G Ohms10 T Ohms (10000 G Ohms)
Automated Test ResultsDielectric Absorption Ratio, Other Dielectric Absorption Ratio, Dielectric Discharge, Other, Step Voltage 
TypeBatteryBattery, Line 
Minimum Insulation Resistance200 K Ohms (0.0002 G Ohms)100 K Ohms (0.0001 G Ohms)
Variable Incremental VoltageYes Yes 
Display (Megohmmeter)DigitalDigital 
Continuity TestNoNo
Live Circuit Voltage DetectionYesYes 
Power SupplyBatteryBattery, Line Powered
TimerYesYes
Other Information

Display: 75 mm x 105 mm

Power: 12 V lead-acid rechargeable battery, Yuasa NP2.8-12

Charger Input (AC): 85 V ac 50/60 Hz 20 VA