Leica Fluke 87V vs Fluke 787


 

 

               Comparison of the Fluke 87V Digital Multimeter and
          Fluke 787 Process Calibration meter:

 
    The Fluke 87V and Fluke 787 are both great meters that would be an asset to any technicians test setup.  Although they are intended for different uses there are still some commonalities. Both meters can measure Resistance, Frequency and AC / DC voltage and current, however, the Fluke 787 is limited to 1A for current measurements.

    The DC and AC voltage accuracy of both meters are similar along with a 10 megohm input impedance, maximum voltage ranges, True RMS, Min/Max, peak hold, auto-ranging.  They both have a backlight display, diode test capabilities. 

    The Fluke 787 is a process calibration meter able to source a 20ma current for process calibration purposes.

    Listed in the table below the images are many of the features and specifications of both meters to view all together at a glance. The differences are highlighted in yellow.
                                Fluke 87-5              Fluke 787
 
 Feature / Model Fluke 87V Fluke 787
Application Technician Process Calibration
AC/DC Amps Yes Yes
Duty Cycle Percentage Yes No
Capacitance Yes - 10000 ufd No
Temperature Yes No
Diode Testing Yes Yes
Display Counts 20000 ( Hi-Res Mode ) 4000
Analog Bargraph Yes - 33 Segment No
Battery Size 9 V 9 V
Warranty 10 Years Limited Lifetime
Frequency 200 Khz 20 Khz
Max DC Voltage 1000 1000
Max AC Voltage 1000 1000
Max DC Current 10A 1A
Max AC Current 10A 1A
Millivolt Range Yes Yes
Relative or Delta Mode Yes Yes
Min / Max Yes Yes
IP Rating IP67 IP67
DC Volts Accuracy ± (0.05% + 1)  0.1% + 1
AC Voltage Accuracy Varies - See Specs Varies - See specs
Maximum Resistance 50 Meg 40 Meg
Minimum Millivolt Meas. .1 mv .1 mv
Wireless Display No No
True RMS Yes Yes
Backlight Yes Yes
Input Impedance 10 Meg 10 Meg
Data Logging Yes Yes
CAT Rating Cat IV 600V, Cat III 1000V Cat III 1000V**
Low Pass Filter Yes No
Overload Protection Yes Yes

                                              **  Complies with IEC1010-1, ANSI/ISA S82.01- 1994 and CAN/CSA C22.2 No. 1010.1-92
                                                   Overvoltage Category III.
 
ModelFluke 787
ProductFluke 787 ProcessMeter
Rating(5)
Price
In Stock

Process / Calibration/Multifunction Calibrators

TypeHand Held
Measure VoltageYes
Voltage Measurement Max1000 V
Voltage Measurement Min1 mV (0.001 V)
Source/Simulate DC CurrentYes
Measure DC CurrentYes
Current Measurement Max1 A (1000 mA)
Current Measurement Min0.001 mA
Source/Simulate ResistanceNo
Measure ResistanceYes
Resistance Measurement Max40 M Ohms (40000000 Ohms)
X