Tariff-related changes may impact pricing, and current surcharges may not yet be reflected in listed prices. Learn More

HVAC Manometers and Micromanometers

 
Dwyer HM3531DLK300 - Differential Pressure Manometer, Range 0-100 psi, 0.2% Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 100 psi (2767.99 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): bar, cmH2O, ftH2O, hPa, inch Hg, kg/cm2, kPa, mbar, mmH2O, mmHg, psi
  • Measurement : Differential
  • Min/Max/Hold: Yes

Your Price: $2,304.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer HM3531DLK600 - Differential Pressure Manometer, Range 0-108 psi, 0.1% of Reading Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 108 psi (2989.43 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): psi
  • Measurement : Differential
  • Min/Max/Hold: Yes

Your Price: $3,321.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer HM3531DLL310 - Differential Pressure Manometer, Range 0-145 psi, 0.2% Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 145 psi (4013.59 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): bar, cmH2O, ftH2O, hPa, inch Hg, kg/cm2, kPa, mbar, mmH2O, mmHg, psi
  • Measurement : Differential
  • Min/Max/Hold: Yes

Your Price: $2,516.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer HM3531DLM110 - Differential Pressure Manometer, Range 0-245 psi, 0.05% Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 245 psi (6781.58 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): bar, cmH2O, ftH2O, hPa, inch Hg, kg/cm2, kPa, mbar, mmH2O, mmHg, psi
  • Measurement : Differential
  • Min/Max/Hold: Yes

Your Price: $3,624.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer HM3531DLM310 - Differential Pressure Manometer, Range 0-245 psi, 0.2% Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 245 psi (6781.58 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): bar, cmH2O, ftH2O, hPa, inch Hg, kg/cm2, kPa, mbar, mmH2O, mmHg, psi
  • Measurement : Differential
  • Min/Max/Hold: Yes

Your Price: $2,516.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer HM3531DLM610 - Differential Pressure Manometer, Range 0-245 psi, 0.1% of Reading Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 245 psi (6781.58 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): bar, cmH2O, ftH2O, hPa, inch Hg, kg/cm2, kPa, mbar, mmH2O, mmHg, psi
  • Measurement : Differential
  • Min/Max/Hold: Yes

Your Price: $3,587.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer HM3531GML310 - Gauge Pressure Manometer, Range 0-145 psi, 0.2% Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 145 psi (4013.59 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): bar, cmH2O, ftH2O, hPa, inch Hg, kg/cm2, kPa, mbar, mmH2O, mmHg, psi
  • Measurement : Gauge
  • Min/Max/Hold: Yes

Your Price: $2,981.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer HM3531GMN310 - Gauge Pressure Manometer, Range 0-507 psi, 0.2% Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 507 psi (14033.71 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): psi
  • Measurement : Gauge
  • Min/Max/Hold: Yes

Your Price: $3,132.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer HM3531GMZ310 - Gauge Pressure Manometer, Range 0-1305 psi, 0.2% Accuracy.
  • Type (Manometer): Digital
  • Max Pressure: 1305 psi (36122.28 IN of H2OWhat's This?)
  • Type of Input: N/A
  • Engineering Units (HVAC): bar, cmH2O, ftH2O, hPa, inch Hg, kg/cm2, kPa, mbar, mmHg, psi
  • Measurement : Gauge
  • Min/Max/Hold: Yes

Your Price: $3,132.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
TSI HM675 Hydronic Manometer
  • Product Height: 7.00 IN
  • Product Length: 21.00 IN
  • Product Width: 17.00 IN
  • HTS/Schedule B Number: 9026.20.8000
  • ECCN Number: EAR99
  • Country of Origin: United States

List Price: $3,645.00

Your Price: $3,280.50

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Fieldpiece JL3MN - Job Link System Manometer Probe
  • Max Pressure: 11.6 psi (321.09 IN of H2OWhat's This?)
  • Engineering Units (HVAC): mbar, psi
  • Measurement : Differential
  • Warranty: 1 YEARS
  • Warranty Details: This probe is warranted against defects in material and workmanship for one year from date of purchase from an authorized Fieldpiece dealer. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect.
  • Product Weight: 0.3 LBS

List Price: $310.00

Your Price: $263.50

Sign-in for GSA Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Dwyer LPTK-01 - Low Pressure Gas Test Kit, 0-15" w.c., 0-8.6 oz/in2
  • Type (Manometer): Analog
  • Measurement : Gauge
  • Product Weight: 1.75 LBS
  • HTS/Schedule B Number: 9026204000
  • ECCN Number: EAR99
  • Country of Origin: China

Your Price: $49.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
null
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

HVAC Manometers and Micromanometers

Manometers are used to measure low differential pressures and used in applications such as adjusting furnace blower fan speed. Modern day digital manometers originated from the inconveniences of the U-tube manometers. U-tube manometers use a glass, U shaped, tube filled with water or other fluid of known specific gravity, such as mercury. Hoses are connected to each end. As differential pressure is applied, the fluid displaces, creating a measurable height difference between columns.

Key Features to Consider in Selecting Manometers
  • Measurement range
  • Ability to change to many different measurement units
  • Min/Max/Data Hold feature
  • Datalogging
  • Zero function for offset correction
  • Kits containing a carrying case and hoses
X