Model | Fluke 87-5 | Fluke 376 FC |
---|
Product | 87-V INDUSTRIAL TRUE RMS MULTIMETER | 1000A AC/DC TRMS CLAMPMETER W/ 18" IFLEX |
---|
Rating | (90) | (12) |
---|
Price | | |
---|
In Stock | | |
---|
Multimeters |
Style | Hand-Held | |
Measures AC V | Yes | |
Measures DC V | Yes | |
Measures AC A | Yes | |
Measures DC A | Yes | |
True RMS | Yes | Yes |
Maximum Voltage AC | 1000 V | 1000 V |
Resolution AC Volts | 0.1 mV | |
Maximum Voltage DC | 1000 V | 1000 V |
Resolution DC Volts | 0.1 mV | |
Maximum Current AC | 10 A Maximum Current AC 20 A for 30 seconds maximum | 2500 A Maximum Current AC 999.9A with Jaw 2500 with iFlex |
Minimum Current AC | 0.1 uA (0.00010 mA) | N/A |
Resolution AC Current | 0.1 uA (0.00010 mA) | |
Maximum Current DC | 10 A Maximum Current DC 20 A for 30 seconds maximum | 999.9 A |
Minimum Current DC | 0.1 uA (0.00010 mA) | N/A |
Resolution DC Current | 0.1 uA (0.00010 mA) | |
Basic Accuracy V DC | ± (0.05 % + 1) | |
# Digit Display | 4.5 | |
Counts | 6000 . Counts 6000 counts updates 4/sec; 19,999 counts in high-resolution mode | N/A |
Backlight | Yes | |
Manual/Autoranging | Both | |
Decibels | No | |
Resistance | Yes Resistance Maximum Resistance 50 Ω Accuracy ±(0.2%+1) Maximum Resolution 0.1Ω | Yes Resistance Range: Up to 6kΩ Resolution: 0.1Ω (≤600 Ω), 1 Ω ≤ 6 kΩ, 10 Ω ≤ 60 kΩ Accuracy: 1% ±5 digits |
Frequency | Yes Frequency Maximum Frequency 200 kHz Accuracy ±(0.005%+1) Maximum Resolution 0.01 Hz | |
Capacitance | Yes Capacitance Maximum Capacitance 9,999 µF Accuracy ±(1%+2) Maximum Resolution 0.01 nF | |
Temperature | Yes Temperature Range: 200.0°C - 1090°C, -328.0°F - 1994.0°F; 80 BK Temperature Probe -40.0°C - 260°C, -40.0°F - 500°F | |
Diode Testing | Yes Diode Testing Range 3 V Resolution 1 mV Accuracy ± (2 % + 1) | |
CAT Rating | IV CAT Rating CAT III 1000 V / CAT IV 600 V | |
CAT Voltage | 1,000 V, 600 V | |
Intrinsically Safe | No | |
Peak Hold | Yes | |
Overload Protector | Yes | |
Kelvin 4-Wire Measurement Capability | No | |
Wireless Display | No | |
Data Hold | Yes | |
Low-Pass Filter | Yes | |
Duty Cycle % | Range: 0.0 to 99.9 % Accuracy: Within ± (0.2 % per kHz + 0.1 %) for risetimes < 1 μs | |
Clamp Meters/Clamp Meters |
Maximum Conductor Size | | 34 MM (1.34 IN) Maximum Conductor Size iFlex offers 7in diameter |
Auto Ranging/Manual | | Auto Ranging |
In-Rush Current | | Yes |
Test Equipment General Attributes |
Unique Features | •Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment •Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument •Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks •Large digit display with bright, two-level backlight makes the 87V significantly easier to read than older models •True-rms ac voltage and current for accurate measurements on non linear signals •Selectable filter for accurate voltage and frequency measurements on motor drives •0.05 % dc accuracy •6000 counts, 3-3/4 digits •4-1/2 digit mode for precise measurements (20,000 counts) •Measure up to 1000 V ac and dc •Measure up to 10 A, 20 A for up to 30 seconds •Built in thermometer lets you carry one less tool (TC probe included) •Frequency to 200 kHz and % duty cycle •Resistance, continuity and diode test
| Transmit results wirelessly via Fluke Connect Includes iFlex Flexible Current Probe |
Warranty | 10 YEARS | 3 YEARS |
Additional Info/Comments | •10,000 µF capacitance range for components and motor caps •Min/Max-Average recording with Min/Max Alert to capture variations automatically •Peak capture to record transients as fast as 250 µs •Relative mode to remove test lead interference from low ohms measurements •Auto and manual ranging for maximum flexibility •Touch Hold to capture stable readings avoiding noisy signals •Large display digits and two-level bright white backlight for increased visibility •Analog bargraph for fast changing or unstable signals •Input Alert provides audible warning against wrong use of input jacks •Improved selectable sleep mode for long battery life •Access door for fast battery changes without breaking the calibration seal •"Classic" design with new removable holster with built in test lead and probe storage •Lifetime warranty | N/A |
Safety Approval | CSA, UL Safety Approval Designed to comply with IEC 1010-1 as a 1000V, CAT III instrument (see pg.2 for definition of CAT III). UL listed to UL3111, TUV licensed to EN 61010-1, CSA 22.2 No. 1010.1:1992 | CE, CSA Safety Approval CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
Interfaces I/O | Other, Analog Input | Bluetooth Interfaces I/O Bluetooth for Fluke Connect |
Product Weight | 0.78 LBS | 410 GRAMS (0.9039 LBS) |
Product Height | 1.25 IN Product Height With Holster and Flex-Stand: 2.06 inches | 45 MM (1.77 IN) |
Product Length | 7.35 IN Product Length With Holster and Flex-Stand: 7.93 inches | 249 MM (9.80 IN) |
Product Width | 3.41 IN Product Width With Holster and Flex-Stand: 3.86 inches | 85 MM (3.35 IN) |
Data Logging | No | Yes Data Logging Via Fluke Connect App |
ECCN Number | 3A992 | 3A992 |
Calibration Included | Factory Calibration | None |
CA Residents | | Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |
Battery Type | 9v Battery Type 9V, NEDA 1604 or 6F22 or 006P 400 hrs typical with alkaline | AA Battery Type 2 x AA |
Power Supply Voltage | Battery Powered | Battery Powered |
Country of Origin | United States | Singapore |
UPC | 095969245241 | 095969558570 |