Model | Fluke 116 | Fluke 179 |
---|
Product | Fluke 116 True-RMS AC/DC HVAC Multimeter with Temperature and Microamp Measurements | Fluke 179 ESFP True-RMS AC/DC Digital Multimeter, 1000V with Analog Bargraph,... |
---|
Rating | (31) | (34) |
---|
Price | | |
---|
In Stock | | |
---|
Multimeters |
Style | Hand-Held | Hand-Held |
Measures AC V | Yes | Yes |
Measures DC V | Yes | Yes |
Measures AC A | Yes | Yes |
Measures DC A | Yes | Yes |
True RMS | Yes | Yes |
Maximum Voltage AC | 600 V Maximum Voltage AC Range / Resolution 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V | 1000 V |
Resolution AC Volts | 0.1 mV Resolution AC Volts Range / Resolution 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V | 0.1 mV |
Maximum Voltage DC | 600 V Maximum Voltage DC Range / Resolution 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V | 1000 V |
Resolution DC Volts | 0.1 mV Resolution DC Volts Range / Resolution 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V | 0.1 mV |
Maximum Current AC | 600 uA (0.0006 A) Maximum Current AC Range / Resolution 600.0 µA / 0.1 µA | 10 A |
Minimum Current AC | 0.1 uA (0.00010 mA) Minimum Current AC Range / Resolution 600.0 µA / 0.1 µA | 0.01 mA |
Resolution AC Current | 0.1 uA (0.00010 mA) Resolution AC Current Range / Resolution 600.0 µA / 0.1 µA | 0.01 mA |
Maximum Current DC | 600 uA (0.0006 A) Maximum Current DC Range / Resolution 600.0 µA / 0.1 µA | 10 A |
Minimum Current DC | 0.1 uA (0.00010 mA) Minimum Current DC Range / Resolution 600.0 µA / 0.1 µA | 0.01 mA |
Resolution DC Current | 0.1 uA (0.00010 mA) Resolution DC Current Range / Resolution 600.0 µA / 0.1 µA | 0.01 mA |
Basic Accuracy V DC | 0.5% Basic Accuracy V DC +/- 0.5 % + 2 counts | 0.09 Basic Accuracy V DC ± (0.09%+2) |
# Digit Display | 3.5 | 3.75 |
Counts | 6000 . Counts Updates 4/sec | 6000 . |
Backlight | Yes | Yes |
Manual/Autoranging | Both | Both |
Decibels | No | No |
Resistance | Yes Resistance Range / Resolution 600.0 Ω / 0.1Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ 40.00 MΩ / 0.01 MΩ | Yes Resistance Accuracy ± (0.9%+1) Max. resolution 0.1 Ω Maximum 50 MΩ |
Frequency | Yes | Yes Frequency Accuracy* ± (0.1%+1) Max. resolution 0.01 Hz Maximum 100 kHz |
Capacitance | Yes Capacitance Range / Resolution 1000 nF / 1 nF 10.00 µF / 0.01 µF 100.0 µF / 0.1 µF 9999 µF / 1 µF 100 µF to 1000 µF | Yes Capacitance Accuracy* ± (1.2%+2) Max. resolution 1 nF Maximum 10,000 µF |
Temperature | Yes Temperature Range / Resolution -40 °C to 400 °C / 0.1 °C -40 °F to 752 °F / 0.2 °F | Yes Temperature Comes with 80bk K type probe Accuracy ± (1.0%+10) Max. resolution 0.1°C Range -40°C/400°C |
Diode Testing | Yes | Yes Diode Testing Range: 2.400V Resolution 0.001 V Accuracy 1 % + 2 |
CAT Rating | III | IV CAT Rating Overvoltage category EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV |
CAT Voltage | 600 V | 1,000 V, 600 V CAT Voltage EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV |
Intrinsically Safe | No | No |
Peak Hold | No | No Peak Hold HOLD: freezes the display at the push of a button Auto HOLD: Display holds present reading until it detects new stable input, then the meter beeps and displays new reading |
Overload Protector | Yes Overload Protector 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 | Yes |
Kelvin 4-Wire Measurement Capability | No | No |
Wireless Display | No | No |
Data Hold | Yes | Yes |
Low-Pass Filter | No | No |
Test Equipment General Attributes |
Unique Features | •Built-in thermometer for HVAC applications •Microamps to test flame sensors •Low input impedance: helps prevent false readings due to ghost voltage •Large white LED backlight to work in poorly lit areas •Resistance, continuity, frequency and capacitance •Min/Max/Average with elapsed time to record signal fluctuations •Compact ergonomic design for one-handed operation •Compatible with optional magnetic hanger (ToolPak™) •CAT III 600 V safety rated | •Manual and automatic ranging •Display Hold and Auto Hold •Frequency and capacitance measurements •Resistance, continuity and diode measurements •Temperature measurements (179) •Min-max-average recording •Closed case calibration through front panel •Ergonomic case with integrated protective holster |
Warranty | 3 YEARS | 1 LIMITED LIFETIME (1 YEARS) |
Warranty Details | N/A | Limited Lifetime Warranty |
Safety Approval | CSA, UL Safety Approval ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 | CSA, UL |
Interfaces I/O | Analog Output, Analog Input | |
IP Rating | IP42 | N/A |
Product Weight | 1.21 LBS | 420 GRAMS (0.926 LBS) |
Product Height | 1.82 IN | 1.69 IN |
Product Length | 6.57 IN | 7.28 IN |
Product Width | 3.31 IN | 3.54 IN |
Data Logging | No | No |
ECCN Number | 3A992 | N/A |
Calibration Included | Factory Calibration Calibration Included Factory Calibrtion without certification. Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 % | Factory Calibration |
Battery Type | 9v | 9v |
Power Supply Voltage | Battery Powered | Battery Powered |
Country of Origin | Singapore | United States |
UPC | 095969324199 | N/A |