FLIR FLIR E5 vs FLIR E6

What is the difference between the FLIR E5 and FLIR E6?

Top Features

FLIR E5
IR Sensor Size 160 x 120
Thermal Sensitivity 60mK
Max Temperature 482 F
Min Temperature -4 F
Thermal Accuracy ±2°C or ±2%
Field of View 45º x 34º
Frame Rate 9 Hz
Screen Size 3-inch
MSX Technology Yes
Drop Test Yes - 2 meters
Ingress Protection IP54
Wi-Fi Connectivity Yes
Battery Life 4-hour
FLIR E6
IR Sensor Size 120 x 90
Thermal Sensitivity 100mK
Max Temperature 482 F
Min Temperature -4 F
Thermal Accuracy ±2°C or ±2%
Field of View 45º x 34º
Frame Rate 9 Hz
Screen Size 3-inch
MSX Technology Yes
Drop Test Yes - 2 meters
Ingress Protection IP54
Wi-Fi Connectivity Yes
Battery Life 4-hour

Overview

The FLIR E5 and FLIR E6 are both part of the FLIR Ex Series of building and industrial thermal imagers. Both cameras are mid-range models in the series - the E5 comes in just below the E6. As such, there are some differences in the specifications of these cameras. The E6 will provide higher resolution images with greater thermal sensitivity, but the E5 is still more than capable of performing demanding industrial duties

Both cameras have the same form factor - being in the same series, they are actually the exact same camera just with different specifications. Each camera weighs just 1.27lbs and features a 3-inch LCD screen, a rechargeable Li-ion battery with 4-hour life, and USB ports for data transfer to PCs. These latest models (2017 and later) also feature WiFi connectivity so you can transfer images wirelessly to the FLIR Tools App and create professional reports faster than ever before.

The chief differences between these cameras are in their IR imaging specifications. The primary difference is infrared image resolution - the E5 has 120x90 resolution, while the E6 has a resolution of 160x120. This means the E6 will give you larger thermal images where more details are clearly visible - whether or not you need this extra resolution will depend on your application. The other main difference is thermal sensitivity - the E6 has 60mK sensitivity while the E5 has 100mK sensitivity. This means the E6 will be more sensitive to temperature variations within a scene. This will also help to provide clearer, sharper images with more accurate temperature data.

Apart from the difference in resolution and sensitivity, these cameras are identical. Both feature FLIR MSX image enhancement which embosses visible details onto thermal images. This eliminates the need for reference images because with MSX, you can clearly see what you are looking at in an image - numbers, labels, and fine details are now clearly visible in your IR images.

Both cameras feature a 9Hz frame rate, -4°F to 482°F temperature measurement range, accuracy to ±2% or ±2°C, and adjustable emissivity. In addition, both cameras are tough enough to stand up to heavy daily use in demanding environments - each features an IP54 rating as well as a 2-meter drop test rating.

Conclusion

The E6 is a higher resolution camera with greater thermal sensitivity, giving you larger images with more visible sharp details. Thanks to higher sensitivity, the E6 will show greater temperature variation in your thermal images. That said, the E5 is still perfectly suitable for most industrial and inspection applications. Your specific application will dictate if the higher resolution E6 is needed.

Both cameras include powerful FLIR features like MSX image enhancement and WiFi connectivity as well as the company’s unbeatable 10-5-2 warranty for 10 years on the IR detector, 5 years on the battery, and 2 years on the product.

Want to know more? Check out the tables below or give us a call at 877-571-7901. We’re happy to answer any questions you may have.

ModelFLIR E6 WiFiFLIR E5 WiFi
ProductFLIR E6 IR Camera w/MSX 160 x 120 Resolution/9Hz- with Wifi...FLIR E5 IR Camera w/MSX 120 x 90 Resolution/9Hz- with WiFi - plus HARD CASE INCLUDED
Rating(13)(30)
Price
In Stock

Thermal Imagers/Building and Industrial Thermal Imagers

Detector Size160 x 120 Sensor120 x 90 Sensor
Thermal Sensitivity60 mK (NETD) 100 mK (NETD) 
Temperature Range Max482 F482 F
Temperature Range Min-4 F-4 F
Image Frequency9 Hz9 Hz
Field of View45x34 Degrees45x34 Degrees
Screen Size3.0 IN3.0 IN
IR/Overlay Fusion ImageYes Yes 
Video OutputYes No
FocusFixedFixed
Laser SpotNoNo
Other Information

Adjustable Level and Span Range: Yes

X