Voltage Datalogger

 
AEMC L562 - 2-Channel Voltage and Current Simple Logger II, 600V Voltage, 1V Current
Catalog: 2126.35
  • Battery Life: 45 DAYS (1080 HRWhat's This?)
  • Max Current: N/A
  • Max Voltage: 600 V
  • Min Current: N/A
  • Min Voltage: 0 V
  • Power Source: Battery

List Price: $490.00

Your Price: $465.50

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • Free $25 Gift Code
  • View Payment Options
AEMC L261 - Simple Logger II (1-Channel, TRMS, 600VAC/DC, DataView Software)
Catalog: 2126.05
  • Max Voltage: 600 V
  • Min Voltage: 0 V
  • Power Source: Battery
  • Battery Life: 45 DAYS (1080 HRWhat's This?)
  • # Inputs/Channels: 1
  • SAMPLE RATE/Intervals: 64 samples per cycle

List Price: $475.00

Your Price: $451.25

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • Free $25 Gift Code
  • View Payment Options
Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger
  • Battery Life: 5 DAYS (120 HRWhat's This?)
  • Max Current: 200 A
  • Max Voltage: 600 V
  • Min Current: 10 A
  • Min Voltage: 10 V
  • Power Source: AC Line, Battery

List Price: $369.59

Your Price: $328.94

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Fluke V3000 FC FC Wireless True-rms AC Voltage Module
Catalog: 4401556
  • Max Voltage: 1000 V
  • Min Voltage: 1 V
  • Power Source: Battery
  • Accuracy: 45 Hz to 500 Hz 1.0 % + 3 500 Hz to 1 kHz 2.0% + 3
  • LCD Screen: Yes
  • Software Included: Yes

List Price: $253.99

Your Price: $231.25

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Fluke V3001 FC FC Wireless DC Voltage Module
Catalog: 4459421
  • Max Voltage: 1000 V
  • Min Voltage: 1 V
  • Power Source: Battery
  • Accuracy: 0.09 % + 3
  • Software Included: Yes
  • Unique Features: Measure up to 1000 V DC. Use as a standalone meter or as part of the system. Use the logging function for recording and saving up to 65,000 readings.

List Price: $253.99

Your Price: $231.25

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Lascar EL-USB-3 - Data Logger Voltage USB Lascar EL-USB-3 ELUSB3 EL USB 3
  • Max Voltage: 30 V
  • Min Voltage: 0 V
  • Power Source: Battery
  • Battery Life: 1 YEARS (8760 HRWhat's This?)
  • # Data Points: 32510
  • # Inputs/Channels: 1

Your Price: $103.49

In Stock:
Hioki MR8880-20 Memory Recorder 4 Channel Fixed Inputs
  • Max Voltage: 600 V
  • Power Source: AC Line, Battery
  • SAMPLE RATE/Intervals: 1 usec per channel
  • Accuracy: +/- 0.5% FS
  • LCD Screen: Yes
  • Software Included: Yes

Your Price: $4,065.00

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Comet U5841M - Datalogger for 3 Voltage Inputs 0-10V and 1 Two-State Input, GSM Modem
  • Max Voltage: 60 V
  • Min Voltage: -20 V
  • Power Source: Battery
  • # Inputs/Channels: 4
  • SAMPLE RATE/Intervals: 1 second to 24 hours
  • Accuracy: ±10 mV

Your Price: $830.00

Sign-in for EDU Pricing!

In Stock:
Comet U5841Msim - Datalogger for 3 Voltage Inputs 0-10V and 1 Two-State Input, GSM Modem, Flat Rate SIM Card
  • Max Voltage: 10 V
  • Min Voltage: 0 V
  • Power Source: Battery
  • # Inputs/Channels: 4
  • SAMPLE RATE/Intervals: 1 second to 24 hours
  • Accuracy: Voltage measurement accuracy: ±20 µA

Your Price: $868.00

Sign-in for EDU Pricing!

In Stock:
Comet U7844Msim - IoT Wireless Four Channel Datalogger with Pulse and Two-State Input, GSM Modem, Flat Rate SIM Card
  • Max Voltage: 30 V
  • Min Voltage: 0 V
  • Power Source: Battery
  • # Inputs/Channels: 4
  • SAMPLE RATE/Intervals: 1 second to 24 hours
  • LCD Screen: Yes

Your Price: $868.00

Sign-in for EDU Pricing!

In Stock:
Fluke V3000 FC Kit FC Wireless Essential KIT With V3000
Catalog: 4465641
  • Style: Hand-Held
  • Measures AC V: Yes
  • Measures DC V: Yes
  • Measures AC A: Yes
  • Measures DC A: Yes
  • Maximum Voltage AC: 1000 V

List Price: $551.99

Your Price: $502.57

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Voltage Datalogger

Voltage Dataloggers (or Data Logger, Data Recorder, Data Acquisition) capture voltage signals over time for study and review later.

Benefits of Dataloggers/Data Recorders
  • Quiet, unattended 24/7 operation
  • Simple to setup and operate. Many portable models available
  • Wide variety of measurement types and measurement speeds possible
  • Help troubleshoot and identify problems in many fields
  • Steady declining cost
Parts of a Voltage Datalogger/Data Recorder
voltage-datalogger
  • Voltage jacks
  • A/D or analog to digital converter and signal conditioning electronics
  • Non-volatile storage memory for the collected data and a method to specify the storage rate and on some models the scan interval
  • PC Communications or other method to move the data to a computer and to configure the unit
  • Optionally a local display and keypad. Not always needed, so “blind” units are a cost saving
Considerations when purchasing a voltage datalogger
  • TRMS capability
  • Monitor cycle frequency and duration
  • Logging duration and interval
  • Sampling rate (some units may sample at one rate but log at a slower rate until a programmed alarm is tripped, for example)
  • CAT safety rating
  • Intermittent problem detection
  • Harmonics
X