Voltage Datalogger

 
Liquid Instruments Moku-Go-M2 - Moku:Go, 10-in-One Portable Hardware Platform (4 Channel PPS)
  • Unique Features: 16-Channel Digital IO 4-Channel Programmable Power Supply Ethernet port
  • Interfaces I/O: Analog Output, LAN / Ethernet, Analog Input , USB-C

As low as: $799.00

In Stock:

To add to cart or request a quote.

Hioki MR8880-20 Memory Recorder 4 Channel Fixed Inputs
  • Max Voltage: 600 V
  • Power Source: AC Line, Battery
  • SAMPLE RATE/Intervals: 1 usec per channel
  • Accuracy: +/- 0.5% FS
  • LCD Screen: Yes
  • Software Included: Yes

Your Price: $4,065.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Hioki MR8880-20 PRO KIT - Memory HiCorder Pro Kit
  • Shipping Weight: 5 LBS
  • Country of Origin: Japan

Your Price: $5,159.00

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
MadgeTech RFVolt2000A-15V - Wireless Voltage Data Logger, LCD screen
Catalog: 901450-00
  • Max Voltage: 160 mV (0.16 VWhat's This?)
  • Min Voltage: 2.5 V
  • Power Source: Battery
  • Battery Life: 43800 HR
  • LCD Screen: Yes
  • Safety Approval: CE

Your Price: $329.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech RFVolt2000A-160MV - Wireless Voltage Data Logger, LCD Screen
Catalog: 901455-00
  • Max Voltage: 160 mV (0.16 VWhat's This?)
  • Min Voltage: -160 mV (-0.16 VWhat's This?)
  • Power Source: Battery
  • Battery Life: 43800 HR
  • LCD Screen: Yes
  • Safety Approval: CE

Your Price: $329.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech RFVolt2000A-2.5V - Wireless Voltage Data Logger, LCD Screen
Catalog: 901460-00
  • Max Voltage: 3 V
  • Min Voltage: -3 V
  • Power Source: Battery
  • Battery Life: 43800 HR
  • LCD Screen: Yes
  • Safety Approval: CE

Your Price: $329.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech RFVolt2000A-30V - Wireless Voltage Data Logger, LCD Screen
Catalog: 901465-00
  • Max Voltage: 32 V
  • Min Voltage: -8 V
  • Power Source: Battery
  • Battery Life: 43800 HR
  • LCD Screen: Yes
  • Safety Approval: CE

Your Price: $329.00

Sign-in for EDU Pricing!

In Stock:
MadgeTech State101A - State Recorder, 4 Hz Second Reading Rate
Catalog: 901571-00
  • Power Source: Battery
  • Battery Life: 87600 HR
  • LCD Screen: No
  • Safety Approval: CE
  • Product Weight: 0.05 LBS
  • Product Height: 0.6 IN

Your Price: $99.00

Sign-in for EDU Pricing!

In Stock:
Comet U5841G - Datalogger for 3 Voltage Inputs, 1 Two-State Input with Built-In 4G Modem
  • Max Voltage: 10 V
  • Min Voltage: 0 V
  • Power Source: Battery
  • Battery Life: N/A
  • # Data Points: N/A
  • # Inputs/Channels: 4

Your Price: $1,120.00

Sign-in for EDU Pricing!

In Stock:
Comet U5841Gsim - Datalogger for 3 Voltage Inputs, 1 Two-State Input, with Built-In 4G Modem and SIM Card
  • Max Voltage: 10 V
  • Min Voltage: 0 V
  • Power Source: Battery
  • Battery Life: N/A
  • # Data Points: N/A
  • # Inputs/Channels: 4

Your Price: $1,170.00

Sign-in for EDU Pricing!

In Stock:
Comet U5841M - Datalogger for 3 Voltage Inputs 0-10V and 1 Two-State Input, GSM Modem
  • Max Voltage: 60 V
  • Min Voltage: -20 V
  • Power Source: Battery
  • # Inputs/Channels: 4
  • SAMPLE RATE/Intervals: 1 second to 24 hours
  • Accuracy: ±10 mV

Your Price: $1,068.00

Sign-in for EDU Pricing!

In Stock:
Comet U5841Msim - Datalogger for 3 Voltage Inputs 0-10V and 1 Two-State Input, GSM Modem, Flat Rate SIM Card
  • Max Voltage: 10 V
  • Min Voltage: 0 V
  • Power Source: Battery
  • # Inputs/Channels: 4
  • SAMPLE RATE/Intervals: 1 second to 24 hours
  • Accuracy: Voltage measurement accuracy: ±20 µA

Your Price: $1,118.00

Sign-in for EDU Pricing!

In Stock:
null
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Voltage Datalogger

Voltage Dataloggers (or Data Logger, Data Recorder, Data Acquisition) capture voltage signals over time for study and review later.

Benefits of Dataloggers/Data Recorders
  • Quiet, unattended 24/7 operation
  • Simple to setup and operate. Many portable models available
  • Wide variety of measurement types and measurement speeds possible
  • Help troubleshoot and identify problems in many fields
  • Steady declining cost
Parts of a Voltage Datalogger/Data Recorder
voltage-datalogger
  • Voltage jacks
  • A/D or analog to digital converter and signal conditioning electronics
  • Non-volatile storage memory for the collected data and a method to specify the storage rate and on some models the scan interval
  • PC Communications or other method to move the data to a computer and to configure the unit
  • Optionally a local display and keypad. Not always needed, so “blind” units are a cost saving
Considerations when purchasing a voltage datalogger
  • TRMS capability
  • Monitor cycle frequency and duration
  • Logging duration and interval
  • Sampling rate (some units may sample at one rate but log at a slower rate until a programmed alarm is tripped, for example)
  • CAT safety rating
  • Intermittent problem detection
  • Harmonics
X