Current Dataloggers

 
AEMC L562 - 2-Channel Voltage and Current Simple Logger II, 600V Voltage, 1V Current
Catalog: 2126.35
  • Battery Life: 45 DAYS (1080 HRWhat's This?)
  • Max Current: N/A
  • Max Voltage: 600 V
  • Min Current: N/A
  • Min Voltage: 0 V
  • Power Source: Battery

List Price: $490.00

Your Price: $465.50

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • Free $25 Gift Code
  • View Payment Options
AEMC AL834 - Simple Logger II 4-Channel TRMS Current Data Logger
Catalog: 2126.14
  • Battery Life: 200 HR
  • Max Current: 3000 A
  • Min Current: 5 A
  • Power Source: Battery
  • # Data Points: N/A
  • # Inputs/Channels: 4

List Price: $1,650.00

Your Price: $1,567.50

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • Free $50 Gift Code | Use Code: AEMC50
  • View Payment Options
Pico CM3 KIT PicoLog CM3 3 Channel Current Monitor Data Logger with Clamps
Catalog: PP803
  • Power Source: USB Powered
  • # Inputs/Channels: 3
  • Accuracy: Accuracy (voltage input) < 200 mV RMS : +/- 1% < 1 V RMS : +/- 2.5%
  • Software Included: Yes
  • Unique Features: Powered from USB port or Ethernet
  • Type (Current): AC

Your Price: $669.00

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger
  • Battery Life: 5 DAYS (120 HRWhat's This?)
  • Max Current: 200 A
  • Max Voltage: 600 V
  • Min Current: 10 A
  • Min Voltage: 10 V
  • Power Source: AC Line, Battery

List Price: $369.59

Your Price: $328.94

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
AEMC L452 - 2-Channel Data Logger (100mV/1v/10VDC) with LCD, Event and Pulse, DataView Software
Catalog: 2153.51
  • HTS/Schedule B Number: 9025.19.8085
  • ECCN Number: EAR99
  • Country of Origin: France

List Price: $500.00

Your Price: $475.00

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • Free $25 Gift Code
  • View Payment Options
HT Instruments XL422 3-Phase Current Data Logger
  • Battery Life: 6 MONTHS (4380 HRWhat's This?)
  • Max Current: 2500 A
  • Min Current: 2 A
  • Power Source: Battery
  • # Data Points: N/A
  • # Inputs/Channels: N/A

Your Price: $1,495.00

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
List Price: $55.00
List Price: $142.00
List Price: $173.00
Triplett ACDL100 - True RMS AC Voltage/Current Datalogger
  • Max Current: 200 A
  • Max Voltage: 600 V
  • Min Current: 10 A
  • Min Voltage: 10 V
  • # Data Points: 100000
  • # Inputs/Channels: 1

List Price: $289.99

Your Price: $197.72

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Triplett ACDL200 - Dual Input True RMS AC Voltage/Current Datalogger
  • Max Current: 200 A
  • Max Voltage: 600 V
  • Min Current: 10 A
  • Min Voltage: 10 V
  • # Inputs/Channels: 2
  • TRMS: Yes

List Price: $349.99

Your Price: $238.62

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
Pico CM3 - Current Data Logger, No Clamps
Catalog: PP815
  • Power Source: USB Powered
  • # Inputs/Channels: 3
  • Accuracy: Accuracy (voltage input) < 200 mV RMS : +/- 1% < 1 V RMS : +/- 2.5%
  • Software Included: Yes
  • Unique Features: Powered from USB port or Ethernet
  • Type (Current): AC

Your Price: $479.00

Sign-in for GSA and EDU Pricing!

In Stock:
  • Free shipping over $99 - Code: FREESHIP
  • View Payment Options
null
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Current Dataloggers

Current Dataloggers (or Data Logger, Data Recorder, Data Acquisition) refers to electronics designed to capture current signals over time for study and review later.

Benefits of Dataloggers/Data Recorders
  • Quiet, unattended 24/7 operation
  • Simple to setup and operate. Many portable models available
  • Wide variety of measurement types and measurement speeds possible
  • Help troubleshoot and identify problems in many fields
  • Steady declining cost
Parts of a Current Datalogger/Data Recorder
current-datalogger
  • Included or accessory current clamps
  • A/D or analog to digital converter and signal conditioning electronics
  • Non-volatile storage memory for the collected data and a method to specify the storage rate and on some models the scan interval
  • PC Communications or other method to move the data to a computer and to configure the unit
  • Optionally a local display and keypad. Not always needed, so “blind” units are a cost saving
Considerations when purchasing a current datalogger
  • Single or three phase current
  • Max current and conductor size
  • Logging duration and interval
  • Sampling rate (some units may sample at one rate but log at a slower rate until a programmed alarm is tripped, for example)
  • CAT rating for safety
  • Neutral and ground current monitoring
  • Intermittent problem detection
  • Harmonic current monitoring
  • Measure voltage also