Chroma Safety Testing / Surge Testing

 
Chroma 19022 - Multi-Channel Hipot Tester (DC/IR)
  • Test Type Hipot: DC, IR
  • Max DC Test Voltage: 8 kV
  • Min DC Test Voltage: 0.05 kV (50 VWhat's This?)
  • Max Trip Current AC Test: 5 mA
  • Min Trip Current AC Test: 0.001 mA
  • Programmable (hipot): Yes
In Stock:
  • View Payment Options
Chat with us for price
Chroma 19022-4 - Multi-Channel Hipot Tester (DC/IR/4CH)
  • Test Type Hipot: DC, IR
  • Max DC Test Voltage: 8 kV
  • Min DC Test Voltage: 0.05 kV (50 VWhat's This?)
  • Max Trip Current DC Test: 5 mA
  • Min Trip Current DC Test: 0.001 mA
  • Programmable (hipot): Yes
Chat with us for price
Chroma 19023-8-20 - Multi-channel Hipot Tester, AC8kV/20mA, 4ch
  • Unique Features: Mode: ACWV/Multi-channel Output Voltage: AC : 0.05~8kV Cutoff Current: AC : 0.01 ~ 20mA
  • Warranty: 2 YEARS
  • Interfaces I/O: GPIB, RS-232, Canbus
  • Product Weight: 88.18 LBS
  • Product Height: 6.85 IN
  • Product Length: 23.62 IN
Chat with us for price
Chroma 19032-P - Electrical Safety Analyzer 500VA
  • Test Type Hipot: AC, DC, Ground Bond, IR
  • Test Method (Safety): IEC 60065, IEC 60335-1, IEC 60601-1, IEC 60950-1
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Min AC Test Voltage: 0.05 V
  • Min DC Test Voltage: 0.05 V
Chat with us for price
Chroma 19035 - Wound Component EST Tester AC/DC/IR/DCR x 8HL Tester
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Min AC Test Voltage: 0.05 V
  • Min DC Test Voltage: 0.05 V
  • Max Trip Current AC Test: 30 mA
Chat with us for price
Chroma 19035-M - Wound Component EST Tester AC/DC/IR/DCR x 6H2L/2wire Tester
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Min AC Test Voltage: 0.05 V
  • Min DC Test Voltage: 0.05 V
  • Max Trip Current AC Test: 30 mA
Chat with us for price
Chroma 19035-S - Wound Component EST Tester AC/DCR x 8HL Tester
  • Test Type Hipot: AC
  • Max AC Test Voltage: 5 kV
  • Min AC Test Voltage: 0.05 V
  • Programmable (hipot): Yes
  • Insulation Resistance Test: No
  • Connection Type: Probe
Chat with us for price
Chroma 19036 - Wound Component EST Analyzer AC/DC/IR/IWT/DCR x 10HL Tester
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 6 kV
  • Max DC Test Voltage: 5 kV
  • Min AC Test Voltage: 0.05 V
  • Min DC Test Voltage: 0.05 V
  • Max Trip Current AC Test: 120 mA
Chat with us for price
Chroma 19054 - Hipot Tester (AC/DC/IR/4CH SCAN)
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Min AC Test Voltage: 0.05 V
  • Min DC Test Voltage: 0.05 V
  • Max Trip Current AC Test: 30 mA
Chat with us for price
Chroma 19055 - Hipot Analyzer (AC/DC/IR) - Guardian 500VA Plus
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Min AC Test Voltage: 0.05 kV (50 VWhat's This?)
  • Min DC Test Voltage: 0.05 kV (50 VWhat's This?)
  • Max Trip Current AC Test: 120 mA
Chat with us for price
Chroma 19055-C - Hipot Analyzer (AC/DC/IR/DLA/CDD)
  • Test Type Hipot: AC, DC, IR
  • Max AC Test Voltage: 5 kV
  • Max DC Test Voltage: 6 kV
  • Min AC Test Voltage: 0.05 kV (50 VWhat's This?)
  • Min DC Test Voltage: 0.05 kV (50 VWhat's This?)
  • Max Trip Current AC Test: 120 mA
Chat with us for price
Chroma 19056 - Hipot Analyzer AC10KV
  • Test Type Hipot: AC
  • Max AC Test Voltage: 10 kV
  • Min AC Test Voltage: 0.1 V
  • Max Trip Current AC Test: 20 mA
  • Min Trip Current AC Test: 0.01 mA
  • Programmable (hipot): Yes
Chat with us for price