General Specifications |
Display |
3½ digit LCD, 1" (25.4 mm); -1,999 to 1,999 |
Display Update Rate |
2.5 Updates/Second |
Display Orientation |
Display may be mounted at 90° increments up to 270° from default orientation |
Overrange |
Display reads 1 on the left most digit |
Programming Method |
Four front mounted rotary control dials accessed when the cover is removed |
Recalibration |
Recommended at least every 12 months. |
Normal Mode Rejection |
60 dB rejection ratio |
Operating Temperature Range |
-40 to 75°C |
Storage Temperature Range |
-40 to 75°C |
Relative Humidity |
0 to 90% non-condensing |
Connections |
Screw terminals accept 12 to 22 AWG wire |
Enclosure |
Explosion-proof die cast aluminum with glass window, 0.30% max copper content, corrosion resistant epoxy coating, color: green. NEMA 4X, IP68. Two ¾" NPT threaded conduit openings. One ¾" NPT nickel plated brass conduit plug with 10 mm hex key fitting installed. |
Mounting |
May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½" to 2½" or DN 40 to 65 mm pipe mounting. |
Overall Dimensions |
5.65" x 5.25" x 4.86" (144 mm x 133 mm x 124 mm) (W x H x D) |
Weight |
5.00 lbs (80 oz, 2.27 kg) |
Warranty |
3 years parts and labor |
Input |
Input |
4-20 mA |
Accuracy |
±0.1% of full span ±1 count |
Temperature Drift |
150 PPM/°C from -40 to 75°C ambient |
Decimal Point |
User selectable decimal point |
Calibration Range |
4 mA input: -1000 to +1000; 20 mA between 20 and 2000 counts greater than 4 mA display. Two point linear display span. |
Maximum Voltage Drop |
1 VDC @ 20 mA with backlight; 4 VDC @ 20 mA with loop-powered backlight |
Input Overload |
Over current protection to 2 A max. |
Loop-Powered Backlight Option |
Factory installed only. Powered directly from the 4-20 mA loop, no batteries required. Backlight can be enabled or disabled via alternative wiring of terminal block. The display brightness will increase as the input signal current increases. |