Yokogawa YPP6060 General Specifications |
Display |
Upper display: 0.60" (15 mm) high.
Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs |
Display Intensity |
Eight user selectable intensity levels |
Display Update Rate |
5/second (200 ms) |
Overrange |
Display flashes 999999 Underrange: Display flashes -99999 |
Display Assignment |
The Upper and Lower displays may be assigned to process values for Channels A (Ch-A), B (Ch-B), or C (Ch-C), toggle between (Ch-A & Ch-B, Ch-A & Ch-C, Ch-B & Ch-C, and Ch-A, Ch-B, & Ch-C), toggle between Channel & units, show channel gross value (no tare) or toggle net (tare) and gross values, show relay set points, max & min values, or Modbus input. The second display may also be set to show engineering units or be off, with no display. |
Front Panel |
NEMA 4X, IP65 |
Programming Methods |
Four front panel buttons, digital inputs, PC and PROPLUS software, Modbus registers, or cloning using Copy function. |
F4 Digital Input Contacts |
3.3 VDC on contact. Connect normally open contacts across F4 to COM. |
F4 Digital Input Logic Levels |
Logic High: 3 to 5 VDC |
Noise filter |
Programmable from 2 to 199 (0 will disable filter) |
Filter Bypass |
Programmable from 0.1 to 99.9% of calibrated span |
Recalibration |
All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months. |
Max/Min Display |
Max (Peak) / min (Valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled. |
Password |
Three programmable passwords restrict modification of programmed settings. |
Non-Volatile Memory |
All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost. |
Power Options |
85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or jumper selectable 12/24 VDC ±10%, 15 W max. |
Fuse |
Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse. |
Isolated Transmitter Power Supply |
Terminals P+ & P-: 24 VDC ± 10%. 12/24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal jumper J4). 85-265 VAC models rated @ 200 mA max, 12/24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply. |
Normal Mode Rejection |
Greater than 60 dB at 50/60 Hz |
Isolation |
4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply. |
Overvoltage Category |
Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III. |
Operating temperature range |
-40 to 65°C. Storage temperature range: -40 to 85°C. Relative humidity: 0 to 90% non-condensing |
Connections |
Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters. |
Enclosure |
1/8 DIN, high impact plastic, UL 94V-0, color: black |
Mounting |
1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided. |
Tightening Torque |
Screw terminal connectors: 5 lb-in (0.56 Nm) |
Overall Dimensions |
4.68" x 2.45" x 5.64"(119 mm x 62 mm x 143 mm) (W x H x D) |
Weight |
9.5 oz (269 g) |
UL File Number |
UL & c-UL Listed. E348677; 508 Industrial Control Equipment. |
Warranty |
3 years parts & labor |
Inputs |
Two inputs, each separately field selectable: 0-20, 4-20 mA, 10 V (0-5, 1-5, 0-10 V), Modbus PV (Slave) |
Channels |
Channel A, Channel B, Channel C (Math channel) |
Programmable Constants |
Constant P (Adder): -99999 to 999999, default: 0.000;
Constant F (Factor): 0.00001 to 999999, default: 1.000 |
Math Functions |
Addition, difference, absolute difference, average, multiplication, division, max of A or B, min of A or B, draw, weighted average, ratio, concentration. |
Sequence of Operations for Input Programing |
- Select Input for A and B
- Set up the engineering units for A, B, and C
- Set up decimal point for A, B, and C
- Scale A & B
- Set up the displays for A, B, or C
- Select the transfer function for A & B (e.g. Linear)
- Select Math function for Channel C
- Program constants for Factor (F) and Adder (P).
- Program cutoff values for A and B
|
Accuracy |
±0.03% of calibrated span ±1 count, square root & |
programmable exponent accuracy range |
10-100% of calibrated span |
Temperature Drift |
0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient |
Signal Input Conditioning |
Linear, square root, programmable exponent, or round horizontal tank volume calculation. |
Multi-Point Linearization |
2 to 32 points for channel A and B |
Programmable Exponent |
1.0001 to 2.9999 |
Low-Flow Cutoff |
0-999999 (0 disables cutoff function) |
Decimal Point |
Up to five decimal places or none:d.ddddd , dd.dddd , ddd.ddd , dddd.dd , ddddd.d , or dddddd . |
Calibration Range |
4-20 mA: minimum span input 1 & input 2: 0.15 mA. ±10 V: minimum span input 1 & 2: 0.10 V. An Error message will appear if input 1 and input 2 signals are too close together. |
Input Impedance |
Voltage ranges: Greater than 500KΩ. Current ranges: 50 - 100KΩ (depending on resettable fuse impedance) |
Input Overload |
Current input protected by resettable fuse, 30 VDC max. Fuse resets automatically after fault is removed. |
Rating |
2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3A @ 30 VDC and 125/250 VAC resistive loads; 1/14 HP (≈ 50 W) @ 125/250 VAC for inductive loads. |
Noise Suppression |
Noise suppression is recommended for each relay contact switching inductive loads. |
Deadband |
0-100% of span, user programmable |
High or Low Alarm |
User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off). |
Relay Operation |
automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode). |
Relay Reset |
User selectable via front panel buttons or digital inputs.
- Automatic reset only (non-latching), when input passes the reset point.
- Automatic + manual reset at any time (non-latching).
- Manual reset only, at any time (latching).
- Manual reset only after alarm condition has cleared (latching).
Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset. |
Time Delay |
0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay. |
Fail-Safe Operation |
Programmable and independent for each relay.
Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state. |
Auto Initialization |
When power is applied to the meter, relays will reflect the state of the input to the meter. |
Protocol |
Modbus® RTU |
Meter Address/Slave ID |
1 - 247 |
Baud Rate |
300 - 19,200 bps |
Transmit Time Delay |
Programmable between 0 and 199 ms |
Data |
8 bit (1 start bit, 1 or 2 stop bits) |
Parity |
Even, odd, or none with 1 or 2 stop bits |
Byte-to-Byte Timeout |
0.01 - 2.54 seconds |
Turn Around Delay |
Less than 2 ms (fixed).
Note: Refer to the PROPLUS Modbus Register Tables located at www.yokogawa-usa.com for details. |
Channels |
4 digital inputs & 4 digital outputs per module |
System |
Up to 2 modules for a total of 8 inputs & 8 outputs |
Digital Input Logic |
High: 3 to 5 VDC
Low: 0 to 1.25 VDC |
Digital Output Logic |
High: 3.1 to 3.3 VDC
Low: 0 to 0.4 VDC |
Source Current |
10 mA maximum |
Sink Current |
1.5 mA minimum |
+5 V Terminal |
To be used as pull-up for digital inputs only. |