| Copper Testing |
| Certification testing |
TIA 568-C.2 Cat 5e, 6, 6A ISO/IEC 11801, EN 50173 Class D, E, EA
Additionally Certifier40G supports TIA 568-C.2-1 Cat 8 ISO/IEC 11801, EN 50173 Class F, FA |
| Autotest time - Cat6A/Class EA |
12 s |
| Autotest time - Class FA |
19 s |
| Maximm cable length for dualended autotest |
500 m |
| Insertion cycles (typical) |
Channel: 10,000
Permanent link: 5,000 |
| Test parameters |
As specified in TIA 1152, IEC 61935-1 |
| Wiremap |
| Loop resistance |
0 to 40 Ω, ±0.1 Ω |
| Length |
0 to 500 m, ±0.5 m (dual-ended testing) |
| Propagation delay and delay skew |
0 to 5000 ns, ±1 ns |
| Attenuation |
0 to 70 dB, ±0.1 dB |
| Pair-to-pair and power sum NEXT |
0 to 85 dB, ±0.2 dB |
| Pair-to-pair and power sum ACR-F |
0 to 85 dB, ±0.2 dB |
| Return loss |
0 to 40 dB, ±0.2 dB |
| ACRN, PS ACRN |
-25 to 85 dB, ±0.5 dB |
| Advanced diagnostics |
Time-domain fault locator for RL and NEXT (200 m) |
| Measurement accuracy |
ANSI/TIA-1152 Level 2G, IEC 61935-1 Draft Level VI (Certifier40G)
ANSI/TIA-1152 Level IIIe, IEC 61935-1 Level IIIe (Certifier10G) |
| Measurement frequency range |
1 to 2,500 MHz (Certifier40G)
1 to 500 MHz (Certifier10G) |
| Fiber Testing - Multimode Encircled Flux Tier 1 (Loss/Length) Test Probes (Certifier40G only) |
| Wavelengths |
850 nm, 1300 nm |
| Autotest time |
10 seconds for dual-ended test |
| Test standards |
TIA-568.3, IEC 14763-3, ISO 11801, Network Limits |
| Measurement length |
0 to 1,000 m, ±1.5 m |
| Transmitter |
| Connector type |
FC |
| EF compliance |
IEC 61280-4-1, TIA-526-14C |
| Power |
-16 to -20 dBm |
| Source type |
LED |
| Spectral width |
±15 nm |
| Receiver |
| Connector type |
Interchangeable (SC, LC, ST) |
| Dynamic range |
12 dB |
| Sensitivity |
-40 dBm |
| Resolution |
0.01 dB |
| Visual fault locator |
| Wavelength |
650 nm |
| Power |
0 dBm |
| Fiber Testing - Single-Mode Tier 1 (Loss/Length) Test Probes (Certifier40G only) |
| Wavelengths |
1310 nm, 1550 nm |
| Autotest time |
10 seconds for dual-ended test |
| Test standards |
TIA-568.3, IEC 14763-3, ISO 11801, Network Limits |
| Measurement length |
0 to 10,000 m, ±1.5 m |
| Transmitter |
| Connector type |
SC |
| Power |
-5 dBm to -9 dBm |
| Source type |
Laser |
| Receiver |
| Connector type |
SC (Adapters for LC available) |
| Dynamic range |
31 dB |
| Sensitivity |
-40 dBm |
| Resolution |
0.01 dB |
| General Specifications |
| Interfaces |
Probe Interface, RJ45 Ethernet, USB host and device, talkset, power jack |
| Display |
Industrial LCD, 6" touch sensitive area on both local and remote units |
| Enclosure |
Ruggedized plastic with rubber overmold, withstands 1.5 m drop test on hard surface |
| Remote unit capabilities |
View test results, edit labels, save results, start autotest |
| Power supply |
AC 100 to 240 V to 12 V, 3 A power adapter |
| Input over-voltage protection |
Protected against Telco voltages |
| Battery |
Removable and rechargeable LiON Battery capacity >8 hours continuous operation |
| Internal storage capacity |
700 MB |
| Dimensions |
232 X 126 X 87 mm (9.1 X 5.0 X 3.4 in) |
| Weight |
Approx. 1 kg (2.2 lb) per unit |
| Calibration period |
1 year (copper calibration stored on mainframe, fiber calibration stored on fiber test probes) |
| Environmental |
| Operating temperature |
0 to 40°C |
| Storage temperature |
-20 to 60°C |
| Relative humidity |
10% to 80% |