Size |
20.5” x 18.9” x 5.9” (52cm x 48cm x 15cm) |
Power |
5 x AA batteries, 1 x 9 volt PP3 battery |
Weight |
13.2lbs (6kg) |
Size |
7.1" x 3.4" x 1.6" (180mm x 85mm x 40mm) |
Weight |
12.59oz (357g) |
Construction |
ABS Body |
Power |
2 x AALR6 ALKALINE (included) |
Display |
Digital |
Depth of penetration in concrete |
approx. 3/4" (20mm) |
Measuring range |
Moisture content for Concrete |
0 → 6.9 % |
Comparative for Gypsum floor screed |
0 → 12 |
CM Equiv Anhydrite/Concrete |
0→2.7 / 0→4.3 |
Reference scale |
0 → 100 |
Relative Humidity |
0 → 99% |
(with optional Hygro-i2 ® probe) |
Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F |
Moisture content for wood (with optional wood pin probes) |
5 → 30 % |
Size |
6.3" x 3.5" x 1.5" (160mm x 85mm x 38mm) |
Weight |
9.5oz (270g) |
Construction |
ABS Body |
Power |
2 x AALR6 ALKALINE (included) |
Display |
Analog |
Depth of penetration |
N/A |
Shallow signal |
up to 0.40” (10mm) |
Deep signal |
up to 1.25" (30mm) |
Wood Moisture Content |
5 to 30% |
Reference scale for building materials |
0 to 100 |
Reusable Ambient RH Probe tests |
Temperature, RH %, Dew Point, Mixing Ratio |
Humidity Range |
0% - 99% RH |
Temperature Range |
-40°C to 80°C (-40°F to 176°F) |
RH Response time |
8 sec |
Temperature Response time |
min. 5 secs. - max. 30 secs. |
Humidity Accuracy |
10% to 90%RH +/-1.8% @ 25°C / 77°F |
Temperature Accuracy |
+/- 0.5°F / 0.3°C |
NIST traceable |
(National Institute of Standards and Technology) |
Size |
3.94” x 3.54” x 1.38” (100mm x 90mm x35mm) |
Weight |
3.53oz (100g) |
Construction |
ABS enclosure |
Power |
1 x AA type battery 1.5 Volt |
Included |
Wall Mounting and Tripod Stand |
Memory |
Memory: 100,000 data point entries (samples of Ambient RH and temperature; SurfaceTemperature) |
Logging Rate |
Logger interval adjustable between 5 minutes and 1 hour |
Transmission Range |
Up to 165ft (50m) line-of-sight |
Bluetooth |
BLE Bluetooth Low Energy 4.2 compliant, Bluetooth 5 advertising |
RELATIVE HUMIDITY SENSOR SPECIFICATIONS |
Range |
0 to 100%RH |
Accuracy |
±1.5%RH Range 0% to 80%RH
±2.0%RH Range 80% to 99%RH (@ 77°F (25°C)) |
Resolution |
0.1% over the complete range |
Drift |
<0.25%RH per year |
TEMPERATURE SENSOR SPECIFICATIONS |
Range |
-40°F to 257°F (-40°C to 125°C) |
Accuracy |
±0.1°F Range 68°F to 140°F
(±0.1 °C Range 20°C to 60°C) |
Sensor Protection |
PTFE Film protects sensor opening from water & dust |
Drift |
<0.04°F (0.03°C) per year |
Temperature range |
-50 to 650 °C (-58°F ~ 1202°F) Distance to Spot ratio: D:S = 12:1 |
Accuracy for targets assuming ambient operating temperature of |
23 to 25 °C (73 to 77°F): -50 ~ 20°C (-58°F ~ 68°F) ±2.5°C(4.5°F) 20°C ~300°C (68°F ~572°F) ±1.0% ±1.0°C (1.8°F) 300°C ~650°C (572°F ~ 1202°F) ±1.5% |
Emissivity |
Digitally adjustable from 0.10 to 1.0 |
Power supply |
9V battery, NEDA 1604A or IEC 6LR61, or equivalent |