Description |
Orion Dual Star pH/ISE dual channel benchtop meter kit with ROSS Ultra glass-body pH electrode, ATC probe, solutions and stand |
Model |
Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter |
Includes |
Dual Star Meter with Electrode Stand; Universal Power Adapter; 8102BNUWP ROSS Ultra Glass Refillable pH Electrode; 927007MD Stainless Steel ATC Probe; 810001 ROSS Storage Solution; 910104, 910107, 910110 pH 4.01, 7.00, 10.01 pH Buffers |
Range (pH) |
-2.000 to 19.999pH |
Accuracy (pH) |
±0.002pH |
Resolution (pH) |
0.1, 0.01, 0.001pH |
Range (mV) |
±1999.9mV |
Range (Relative mV) |
±1999.9mV |
Range (ORP) |
±1999.9mV |
Resolution (mV) |
0.1mV |
Accuracy (mV) |
±0.2 mV or ±0.05% of reading whichever is greater |
Range (ISE) |
0.0001 to 19900 with selectable units of ppm, Molar, mg/L, % or unit-less |
Resolution (ISE) |
0.0001 minimum, 1 to 3 significant digits (user selectable) |
Accuracy (ISE) |
±0.2 mV or ±0.05% of reading whichever is greater |
Advanced ISE Functions |
Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability, incremental techniques including single known addition, single known subtraction, double known addition and double known subtraction |
Calibration |
pH with calibration editing option, ion concentration (ISE) with calibration editing option, relative mV (RmV), ORP and temperature |
Calibration Points (pH) |
1 to 6 |
Calibration Points (ISE) |
2 to 6 |
Calibration Points |
1 point relative mV (RmV) mode, 1 point ORP mode |
Isopotential Point |
7.000pH (adjustable), 1.000 ISE (adjustable) |
Range (Temperature) |
-5.0° to 105.0°C, 22.0° to 221.0°F |
Resolution (Temperature) |
0.1°C, 0.1°F |
Accuracy (Temperature) |
±0.1°C |
Temperature Selection |
Manual or automatic with ATC temperature probe |
Temperature Probe Calibration |
1 point temperature offset calibration |
Channels |
2 |
Backlight Option |
Yes, adjustable |
Display Type |
Graphic LCD with backlight |
Keypad |
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Measurement Modes |
pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature |
Stability |
Smart Stability and Smart Averaging |
Data Management Details |
Transfer single, range or all data points to printer or computer |
Log Function Type |
Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and Timed Reading measure modes; manual data logging with Continuous measure mode |
Data Points |
1000 with date and time stamp |
Alarm Output |
High/low limit alarm |
Memory |
Non-volatile memory preserves data log, calibration log and meter settings |
Methods |
10 per channel with password protection |
Inputs |
Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Outputs |
USB, RS232 |
Languages |
English, Spanish, French, Italian and German |
Probe Type |
pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe) |
AC Adapter |
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Power Supply |
Universal AC adapter (included) |
Voltage |
90 to 260VAC |
Electrical Requirements |
90 to 260VAC 50/60Hz |
Temperature (English) Operating |
41° to 113°F (ambient) |
Temperature (Metric) Operating |
5° to 45°C (ambient) |
Relative Humidity Range |
5 to 85 %, non-condensing |
Dimensions (L x W x H) |
24 x 17 x 9cm (9.5 x 6.7 x 3.5 in.) |
Weight (English) |
2 lb. |
Weight (Metric) |
0.9kg |
Certifications/Compliance |
CE, TUV 3-1, FCC Class A |
Warranty |
3 year meter warranty |
Unit Size |
Each |