Description |
Orion Dual Star pH/ISE dual channel benchtop meter nitrate & pH kit with Orion nitrate ion selective electrode, ROSS Sure-Flow glass-body pH electrode, ATC probe, solutions and stand |
Model |
Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter |
Includes |
Dual Star pH/ISE dual channel meter, 9707BNWP Orion nitrate ion selective electrode, 8172BNWP ROSS Sure-Flow glass-body pH electrode, 927007MD Orion stainless steel ATC probe, 096019 Orion Star series stirrer probe, 930707 Orion 100 ppm nitrate standard (475 mL), 930711 Orion nitrate ISA ionic strength adjuster (475 mL), 810199 ROSS pH buffer and solution kit, electrode stand, computer interface cable, universal power supply, literature and meter test certificate |
Range (pH) |
-2.000 to 19.999pH |
Accuracy (pH) |
±0.002pH |
Resolution (pH) |
0.1, 0.01, 0.001pH |
Range (mV) |
±1999.9mV |
Range (Relative mV) |
±1999.9mV |
Range (ORP) |
±1999.9mV |
Resolution (mV) |
0.1mV |
Accuracy (mV) |
±0.2 mV or ±0.05% of reading whichever is greater |
Range (ISE) |
0.0001 to 19900 with selectable units of ppm, Molar, mg/L, % or unit-less |
Resolution (ISE) |
0.0001 minimum, 1 to 3 significant digits (user selectable) |
Accuracy (ISE) |
±0.2 mV or ±0.05% of reading whichever is greater |
Advanced ISE Functions |
Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability, incremental techniques including single known addition, single known subtraction, double known addition and double known subtraction |
Calibration |
pH with calibration editing option, ion concentration (ISE) with calibration editing option, relative mV (RmV), ORP and temperature |
Calibration Points (pH) |
1 to 6 |
Calibration Points (ISE) |
2 to 6 |
Calibration Points |
1 point relative mV (RmV) mode, 1 point ORP mode |
Isopotential Point |
7.000pH (adjustable), 1.000 ISE (adjustable) |
Range (Temperature) |
-5.0° to 105.0°C, 22.0° to 221.0°F |
Resolution (Temperature) |
0.1°C, 0.1°F |
Accuracy (Temperature) |
±0.1°C |
Temperature Selection |
Manual or automatic with ATC temperature probe |
Temperature Probe Calibration |
1 point temperature offset calibration |
Channels |
2 |
Backlight Option |
Yes, adjustable |
Display Type |
Graphic LCD with backlight |
Keypad |
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Measurement Modes |
pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature |
Stability |
Smart Stability and Smart Averaging |
Data Management Details |
Transfer single, range or all data points to printer or computer |
Log Function Type |
Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and Timed Reading measure modes; manual data logging with Continuous measure mode |
Data Points |
1000 with date and time stamp |
Alarm Output |
High/low limit alarm |
Memory |
Non-volatile memory preserves data log, calibration log and meter settings |
Methods |
10 per channel with password protection |
Inputs |
Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Outputs |
USB, RS232 |
Languages |
English, Spanish, French, Italian and German |
Probe Type |
pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe) |
AC Adapter |
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Power Supply |
Universal AC adapter (included) |
Electrical Requirements |
90 to 260VAC 50/60Hz |
Temperature (English) Operating |
41° to 113°F (ambient) |
Temperature (Metric) Operating |
5° to 45°C (ambient) |
Relative Humidity Range |
5 to 85 %, non-condensing |
Dimensions (L x W x H) |
24 x 17 x 9cm (9.5 x 6.7 x 3.5 in.) |
Weight (English) |
2 lb. |
Weight (Metric) |
0.9kg |
Certifications/Compliance |
CE, TUV 3-1, FCC Class A |
Warranty |
3 year meter warranty |
Unit Size |
Each |