Use the testo 440 dP air velocity and IAQ measuring instrument in combination with high quality probes to measure and store all air velocity and IAQ parameters. Up to 3 probes can be connected simultaneously – a Bluetooth probe, a wired probe, and a temperature probe with a type K thermocouple connector (probes sold separately). Automatic probe detection and clearly structured measurement menus guarantee simple operation and will make your day-to-day work easier.
The testo 440 dP comes with an integrated differential pressure sensor. This enables filter and fan measurements, as well as pitot tube and K factor measurements (pitot tube sold separately)
Measure in no time with the testo 440 dP multifunction measuring instrument
Carry out your measurements quickly and easily. This multifunction instrument automatically detects each connected probe, which means you won't need to manually reset measurement parameters when changing probes. Clearly structured measurement menus for measuring the volume flow in ducts and at outlets, funnel measurement, determining volume flow via differential pressure and K factor, measuring the degree of turbulence, determining heating/cooling output, mold detection, and long-term measurement provide you with the optimal support for quick and efficient work.
A wireless space saver: More applications, less equipment
Endlessly versatile – the universal probe handle can be connected to all probe heads, so you can measure everything you need, while saving money and space.
The Bluetooth probe handle makes it more convenient to carry out your measurements, and guarantees less cable clutter in your case. It makes it possible to carry out measurements without any bothersome cable connections, and it transfers readings up to a distance of 65 feet. If using a wireless connection is not possible, use the cable probe handle as a practical alternative.
Practical measurement data management
The testo 440 dP stores up to 7,500 measurement protocols, which can be read via USB port and further processed as a CSV file on your computer (e.g. with Excel). With the testo Bluetooth / IrDA printer (sold separately), you have the ability to produce a printed report of measurement data directly on site.
Intelligent calibration concept for maximum precision
You can rely on the accuracy of your measurement results with our digital probes, because the testo 440 dP makes measurement uncertainty a thing of the past. You only need to send the probes in for calibration, meaning the multifunction instrument can remain in continuous use with a variety of interchangeable probes.
Advantages of measuring with the testo 440 dP air velocity and IAQ measuring instrument
Precise and reliable in ducts and at air outlets
- Large range of connectable probes: Hot wire and vane probe (Ø 0.6") for measurements in ducts, large vane probes (Ø 4") for measurements at air/ceiling outlets
- Calculate volume flow quickly: In the measurement menu, simply configure the dimensions and geometry of the duct cross-section and see the volume flow displayed straight away
- Easy to carry out measurements in larger ducts, due to the extendable telescope on the hot wire and vane probes (Ø 0.6"), up to a total length of about 6.5 feet
- Carry out measurements at air/ceiling outlets effortlessly, without using a ladder – fit the vane probe (Ø 4") with the extendable telescope and 90° angle (both sold separately)
- Use the vane probes in conjunction with the testo vent measurement funnels and flow straighteners to test incoming / outgoing air at plate outlets, ventilation grills, and swirl outlets
- Practical Bluetooth interface: Use the air velocity probes to measure without having to deal with any bothersome cables, operate the measuring instrument by pressing the button on the handle of the probe, e.g. to start or stop a timed mean calculation
- Use the practical rear magnets to securely attach the multifunction measuring instrument to metal surfaces (e.g. ventilation ducts)
Long-term monitoring of indoor air quality
- The right probe for your requirements: Probes for CO2, CO, and air temperature and humidity are available as wired or Bluetooth variants
- Easy to use: Enter the measurement period and interval for long-term measurement, and track it over the course of the day
- Internal memory for up to 7,500 measurement protocols
Turbulence measurement in accordance with EN ISO 7730 / ASHRAE 55
- Attain a high level of accuracy, even at low air velocities, with a turbulence probe
- Automatic calculation of draft risk and degree of turbulence in accordance with EN ISO 7730 / ASHRAE 55
- For convenient measurements at varying heights, we recommend using our measuring tripod for comfort level measurement – this makes it easy to position turbulence probes in compliance with testing standards
Wide range of probes for laboratories and cleanrooms
- Fume hood probe for high precision air velocity measurements
- Thanks to its low startup speed of 0.1 m/s, the available vane probe (Ø 4") is ideal for laminar flow measurements in cleanrooms, available as a wired or Bluetooth variant
- High precision temperature / humidity probe (0636 9771 or 0636 9772) with an accuracy of ±0.6% RH + 0.7% of m.v. in the 0-90% RH range for measuring the humidity in cleanrooms