Televes 234311 T.0X Broadband Fiber Optic Transmitter (1550nm / 10dBm)
Optical Transmitters
Are transmitters that generate an optical output of 1310 or 1550 nm, modulated by the incoming RF signal.
- Optical output power up to 10 dBm
- Control of RF input level for adjusting the quality parameters of optical transmission
- Feature control signals for monitoring the optical output signal
- Equipped with tension-free connections (relay) that allow implementing an alarm when the optical power falls.
Televes T.0X Broadband Fiber Optic Transmitter
Are transmitters that generate an optical output of 1310 or 1550 nm, modulated by the incoming RF signal. In addition, Ref. 2334, 233411 and Ref. 233410 feature optical reception in the return channel.
Safety instructions:
Caution Statements
- Product inspection - Inspect the equipment for shipping damage. Should any damage be discovered, immediately file a claim with the carrier.
- Important Safety Instructions - To ensure proper installation and operation, take a moment to read this guide before proceeding with the installation. If you have any questions or comments about the T.0X Series Optical Fiber Transmitters and Receivers please contact your dealer.
WARNING: TO PREVENT FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE TO RAIN OR MOISTURE.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
|
A product and cart combination should be moved with care. Quick stops, excessive force and uneven surfaces may cause the product and cart combination to overturn. |
|
The lightning ‚ash with arrow head symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of su†cient magnitude to constitute a risk of electric shock to persons. |
|
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. |
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT OPEN THE CABINET, REFER SERVICING TO QUALIFIED PERSONNEL ONLY.
CAUTION: TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
Important Safety Instructions:
- Read and Follow All Instructions - All the safety and operating instructions should be read prior to and followed while operating this product.
- Retain Instructions - The safety and operating instructions should be retained for future reference.
- Heed Warnings - All warnings on the product and in the operating instructions should be adhered to
- Cleaning - Disconnect this product from any electrical source before cleaning. Use a damp cloth; do not use liquid or aerosol cleaners.
- Attachments - Do not use attachments that are not recommended by the product manufacturer as they may cause hazards.
- Water and Moisture - Do not use this product near any source of water.
- Mounting – Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury to persons or nearby objects, and serious damage to this product. Use only with a cart, stand, tripod, bracket, or table recommended by the manufacturer, or sold with the product. Any mounting of the product should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufacturer.
- Ventilation – Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product. These openings should never be blocked or covered in any way. This product should not be placed in any case, cabinet, or rack unless proper ventilation is provided and the manufacturer’s instructions have been adhered to.
- Power Sources - This product should be operated only from the type of power source indicated on the marking label.
- Grounding or Polarization - Do not bypass or defeat electrical plug polarization or grounding. Doing so will violate the warranty and may pose a risk of fire or electrocution.
- Wire Protection – Ensure all connected wiring is routed correctly to avoid damage including pinching, excessive bends, or compression.
- Electrical Supply, Grounding, and Surge Protection – Ensure that all local or national electrical codes are followed. Seek the advice of a licensed electrician, professional engineer, or other licensed expert. See example wiring figure.
- Power Lines - Always use caution and avoid operating this or any connected equipment near uninsulated power line or any other hazards.
- Object and Liquid Entry - Never allow objects or liquid of any kind into this product through openings. Doing so could result in fire or electric shock.
- Servicing – There are no user serviceable parts. Do not attempt to service this product or remove covers. Doing so may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. Examples of damage requiring service include but are not limited to: - Damage to power-supply wiring.
- If liquid has been spilled, or objects have fallen into the product.
- If the product has been exposed to rain or water.
- If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to its normal operation.
- If the product has been dropped or physically damaged.
- When the product exhibits a distinct change in performance.
- Replacement Parts - Ensure that repairs are performed by qualified technicians and that only manufacturer supplied or authorized parts are used.
- Safety Check – Upon completion of any service or repairs to this product, ensure safety checks to determine that the product is functioning per manufacturer specifications are performed.
- Heat - The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products (including amplifiers) that produce heat. Ensure that ambient temperature is maintained in the manufacturer specified operating range.
Optical connection instructions:
- An SC/APC single mode fiber cable must be used. Remove the protective cover from the optical connector on the unit and the cap on the cable connector.
- Carefully align the guides on both connectors when plugging a cable to the device, then push the connector all the way in.
- Take special care to avoid damaging the unprotected ends of the connectors, as small scratches, impurities and/or particles of dirt, oil, grease, sweat, etc. may significantly ažect the quality of the signal.
- To clean the ends of the connectors, gently rub with a lint-free lens cleaning cloth, dampened using additive-free isopropyl alcohol. Make sure the alcohol evaporates fully before connecting. Keep the connector covers and cable caps in a safe place in case they are needed in the future. Always fit the covers on the connectors of devices that are not connected to cables to prevent the laser beam from damaging the eyes.
- Do not turn the transmitter on without a fiber optic cable connected to it.
Warning:
- This product emits an invisible laser beam. Avoid contact with laser radiation. The use of binoculars or magnifying glasses may increase damage caused to the eyes.
According to EN60825-1_ 2007
- The use of the equipment in any other way than the specified in this manual may lead to exposure to harmful radiation.
- Do not use the equipment in any way that does not comply with the operating instructions or in any conditions that exceed the stipulated environmental specifications.
- Never point the laser beam at people or animals.
19” Rack Mounting