T3SA3200 |
T3SA3100 |
Measurement range |
DANL to +10 dBm, 100 kHz ~ 1 MHz, preamplifier off DANL to +20 dBm, 1 MHz ~ 3.2 GHz, preamplifier off |
Reference level |
-100 dBm to +30 dBm, 1 dB steps Preamplifier |
20 dB (nom.), 9 kHz ~ 3.2 GHz Input attenuation |
0 ~ 51 dB, 1 dB steps |
Maximum input DC voltage |
±50 VDC |
Maximum average RF power |
30 dBm, 3 minutes, fc ≥ 10 MHz, attenuation > 20 dBm, preamp off Maximum |
damage level |
33 dBm, fc ≥ 10 MHz, attenuation > 20 dBm, preamp off |
&nbps; |
20°C ~ 30°C, attenuation = 0 dB, sample detector, trace average > 50 |
Preamp off |
|
RBW = 10 Hz |
Normalization to 1 Hz |
9 kHz ~ 100 kHz |
-100 dBm (nom.) |
-110 dBm (nom.) |
100 kHz ~ 1 MHz |
-97 dBm, -101 dBm (typ.) |
-107 dBm, -111 dBm (typ.) |
1 MHz ~ 10 MHz |
-122 dBm, -126 dBm (typ.) |
-132 dBm, -136 dBm (typ.) |
10 MHz ~ 200 MHz |
-127 dBm,-131 dBm (typ.) |
-137 dBm, -141 dBm (typ.) |
200 MHz ~ 2.1 GHz |
-125 dBm, -129 dBm (typ.) |
-135 dBm, -139 dBm (typ.) |
2.1 GHz ~ 3.2 GHz |
-116 dBm, -122 dBm (typ.) |
-126 dBm, -132 dBm (typ.) |
Preamp on |
9 kHz ~ 100 kHz |
-107 dBm (nom.) |
-117 dBm (nom.) |
100 kHz ~ 1 MHz |
-122 dBm, -127 dBm (typ.) |
-132 dBm, -137 dBm (typ.) |
1 MHz ~ 10 MHz |
-138 dBm, -144 dBm (typ.) |
-148 dBm, -154 dBm (typ.) |
10 MHz ~ 200 MHz |
146 dBm, -151 dBm (typ.) |
-156 dBm, -161 dBm (typ.) |
200 MHz ~ 2.1 GHz |
-145 dBm, -148 dBm (typ.) |
-155 dBm, -158 dBm (typ.) |
2.1 GHz ~ 3.2 GHz |
-135 dBm, -139 dBm (typ.) |
-145 dBm, -149 dBm (typ.) |
|
20°C ~ 30°C, f c= 1 GHz |
Phase Noise |
<-95 dBc/Hz @10 kHz offset, <-98 dBc/Hz (typ.) |
<-96 dBc/Hz @100 kHz offset, <-97 dBc/Hz (typ.) |
<-115 dBc/Hz @1 MHz offset, <-117 dBc/Hz (typ.) |
Logarithmic level axis |
10 dB to 200 dB |
Linear level axis |
0 to reference leve |
Units of level axis |
dBm, dBmV, dBμV, dBμA, V, W |
Number of display points |
751 |
Number of traces |
4 |
Trace detectors |
Positive-peak, Negative-peak, Sample, Normal, Average (Voltage/RMS/Video), Quasi-peak (with EMI option) |
Trace functions |
Clear write, Max Hold, Min Hold, View, Blank, Average |
|
20°C to 30°C, 30 % to 70 % relative humidity, attenuation = 20 dB, reference frequency 50 MHz |
Preamp off |
±0.8 dB |
±0.4 dB, (typ.) |
Preamp on |
±0.9 dB |
±0.5 dB, (typ.) |