Tektronix Logic Analyzers TLA7N4 Logic Analyzer Module Characteristics General Number of Channels (all channels are acquired including clocks) - TLA7N4: 136 channels (4 are clock and 4 are qualifier channels). Channel Grouping - No limit to number of groups or number of channels per group (all channels can be reused in multiple groups). Module "Merging" - Three modules can be "merged" to make up to a 408-Channel module. Merged modules exhibit the same depth as the lesser of the three individual modules. Word/range/setup-and-hold/glitch/transition recognizers span all three modules. Only one set of clock connections is required. Time Stamp - 50-Bit at 500 ps resolution (6.5 day range). Clocking/Acquisition Modes - Internal, internal 2X, external. 2 GHz MagniVu high-speed timing is available simultaneous with all modes. Number of Mainframe Slots Required per TLA Series Module - 2. Input Characteristics (with P6417, P6418, P6419, or P6434 probes) Capacitive Loading - <0.7 pF data and clock (P6419). 1.4 pF typical data; 2 pF typical clock (P6418). 2 pF typical data and clock (P6417 & P6434). Threshold Selection Range - From +5.0 V to -2.0 V in 50 mV increments. Threshold Selection Channel Granularity - Separate selection for clock (1) and data (16) for each 17-Channel probe connector. Threshold Accuracy (including probe) - ±100 mV. Input Voltage Range - Operating: 6.5 Vp-p centered around the programmed threshold. Non-destructive: ±15 V. Minimum Input Signal Swing - 250 mV or 25% of signal swing, whichever is greater (P6417, P6418, & P6419). 300 mV or 25% of signal swing (P6434). Input Signal Minimum Slew Rate - 200 mV/ns typical. State Acquisition Characteristics (with P6417, P6418, P6419, or P6434 probes) State Clock Rate - 100 MHz standard, 200 MHz optional. State Data Rate (half/full channels) - 400/200 Mb/s, typical. Requires 200 MHz state option. State Memory Depth with Timestamps - 64 Kb, 256 Kb, 1 Mb, or 4 Mb per channel. Setup-and-hold Time Selection Range - From 8.5 ns before, to 7.0 ns after clock edge. Setup-and-hold Window - 2 ns typical. Minimum Clock Pulse Width - 2 ns. Active Clock Edge Separation - 5 ns. Demux Channel Selection - Channels can be demultiplexed to other channels through user interface with 8-Channel granularity. Timing Acquisition Characteristics (with P6417, P6418, P6419, or P6434 probes) MagniVu™ Timing - 500 ps. MagniVu Timing Memory Depth - 2 Kb (2048) per channel. Deep Timing Resolution (half/full channels) - 2/4 ns to 50 ms. Deep Timing Resolution with Glitch Storage Enabled - 10 ns to 50 ms. Deep Timing Memory Depth (half/full channels with timestamps and with or without transitional storage) - 128/64 Kb, 512/256 Kb, 2/1 Mb, 8/4 Mb per channel. Deep Timing Memory Depth with Glitch Storage Enabled - Half of default main memory depth. Channel-to-channel Skew - <1 ns typical. Minimum Recognizable Pulse Width (single channel) - 2 ns. Minimum Recognizable Glitch Width (single channel) - 2 ns. Minimum Recognizable Multi-channel Trigger Event - Sample period +2 ns. Trigger Characteristics Independent Trigger States - 16. Maximum Independent If/then Clauses per State - 16. Maximum Number of Events per If/then Clause - 8. Maximum Number of Actions per If/then Clause - 8. Maximum Number of Trigger Events - 18 (2 counter/timers plus any 16 other resources). Number of Word Recognizers - 16. Number of Range Recognizers - 4. Number of Transition Recognizers - 1. Number of Counter/Timers - 2. Trigger Event Types - Word, group, channel, transition, range, anything, counter value, timer value, signal, glitch, setup-and-hold violation. Trigger Action Types - Trigger module, trigger all, store, don't store, start store, stop store, increment counter, reset counter, start timer, stop timer, reset timer, goto state, set/clear signal, do nothing. Trigger Sequence Rate - DC to 250 MHz (4 ns). Counter/Timer Range - 51 Bits each (>100 days at 4 ns). Counter Rate - DC to 250 MHz (4 ns). Timer Clock Rate - 250 MHz (4 ns). Counter/Timer Latency - None (can be tested or reset immediately after starting). Range Recognizers - Double bounded (can be as wide as any group, must be grouped according to specified order of significance). Setup-and-hold Violation Recognizer Setup Time Range - From 8 ns before to 7 ns after clock edge in 0.5 ns increments. Setup-and-hold Violation Recognizer Hold Time Range - From 7 ns before to 8 ns after clock edge in 0.5 ns increments. Trigger Position - Any data sample. MagniVu Trigger Position - MagniVu data is centered around the module trigger. Storage Control (data qualification) - Global (conditional), by state (start/stop), by trigger action, or transitional. Storage Window Granularity - Single sample or block-of-31 samples before and after. Safety - CSA C22.2 No. 1010.1, EN61010-1, IEC61010-1, UL 3111-1 Physical Physical Characteristics Dimensions | mm | in. | Height | 262 | 10.3 | Width | 61 | 2.4 | Depth | 381 | 15 | Weight | kg | lb. | Net (w/o probes) | 3.1 | 6.7 | Shipping (typical) | 6.3 | 13.7 | |