| Measurements |
| Available measurements |
| V rms - Volts RMS |
VDF - Volts Distortion Factor |
| A rms - Amps RMS |
VTIF - Volts Telephone Influence Factor |
| WATT - Watts |
ATHD - Amps Total Harmonic Distortion |
| VA - Volt-Amps |
ADF - Amps Distortion Factor |
| VAR - Volt-Amps Reactive |
ATIF - Amps Telephone Influence Factor |
| FRQ - Frequency |
VF - Fundamental Volts rms |
| PF - Power factor |
AF - Fundamental Amps rms |
| VPK+ - Volts peak (positive) |
IMP - Impedance |
| VPK- - Volts peak (negative) |
RES - Resistance |
| APK+ - Amps peak (positive) |
REA - Reactance |
| APK- - Amps peak (negative) |
HR - Integrator time |
| VDC - Volts DC |
WHR - Watt Hours |
| ADC - Amps DC |
VAH - VA Hours |
| VRMN - Volts rectified mean |
VRH - VAr Hours |
| ARMN - Amps rectified mean |
AHR - Amp Hours |
| VCF - Voltage crest factor |
WAV - Average Watts |
| ACF - Current crest factor |
PFAV - Average Power Factor |
| VTHD - Volts Total Harmonic Distortion |
CVAR - Correction VArs |
| Voltage and current ranges |
| Voltage Ranges |
2000 V peak , 1000 V peak , 500 V peak , 200 V peak , 100 V peak , 50 V peak , 20 V peak , 5 V peak , 2 V peak |
| Current Ranges (30 A Shunt) |
200 A peak , 100 A peak , 50 A peak , 20 A peak , 10 A peak , 5 A peak , 2 A peak , 1 A peak , 0.5 A peak , 0.2 A peak , 0.1 A peak |
| Current Ranges (1 A Shunt) |
5 A peak , 2 A peak , 1 A peak , 0.5 A peak , 0.2 A peak , 0.1 A peak , 0.25 A peak , 0.0125 A peak , 0.005 A peak , 0.0025 A peak |
| Current Ranges (External Shunt) |
3 V peak , 1.5 V peak , 0.75 V peak , 0.3 V peak , 0.15 V peak , 0.075 V peak , 0.03 V peak , 0.015 V peak , 0.0075 V peak |
| Measurement accuracy - voltage and current |
| Voltage Accuracy, V rms ( 45 Hz - 850 Hz ) |
±0.04% of Reading ± 0.04% of Range ± 0.02 V |
| Voltage Accuracy, V rms ( 10 Hz - 45 Hz, 850 Hz - 1 MHz ) |
± 0.05% of Reading ± 0.05% of Range ± (0.02*F)% of Reading ± 0.02 V (typical) |
| Voltage Accuracy, DC |
± 0.05% of Reading ± 0.1% of Range ± 0.05 V |
| Voltage Accuracy, V rmn |
± 0.2% of Reading ± 0.1% of Range ± 0.1 V |
| Effect of Common Mode (Typical) |
1000 V, 60Hz < 10 mV
100 V, 100 kHz < 50 mV |
| Current Accuracy, A rms ( 45 Hz - 850 Hz ) |
± 0.04% of Reading ± 0.04% of Range ± (20 μV/Z ext ) |
| Current Accuracy, A rms ( 10 Hz - 45 Hz, 850 Hz - 1 MHz ) |
± 0.05% of Reading ± 0.05% of Range ± (0.02*F)% of Reading ± (20 μV/Z ext ) (typical) |
| Current Accuracy, DC |
± 0.05% of Reading ± 0.1% of Range ± (50 μV/Z ext ) |
| Current Accuracy, A rmn |
± 0.2% of Reading ± 0.1% of Range ± (100 μV/Z ext ) |
| Measurement accuracy - power |
| Watts Accuracy |
(V rms acc. x A rms x PF) ± (A rms acc. x V rms x PF) ± (V rms x A rms x cos θ -cos { θ± (Vh1 ph.err. ± Ah1 ph.err. )}) |
| VA Accuracy |
(V rms acc. x A rms ) ± (A rms acc. x V rms ) |
| VAR Accuracy |
![]() |
| PF Accuracy |
Cos θ -cos [ θ± ( Vh1 ph.err ± Ah1 ph.err )] ± 0.001 |
| Measurement accuracy - Harmonic magnitude and phase |
| Voltage Harmonics (45 Hz - 850 Hz) (Typical for 10 Hz to 45 Hz and 850 Hz to 1 MHz) |
± 0.08% of Reading ± 0.08% of Range ± (0.02*F)% of Reading ± 0.02 V |
| Voltage Harmonics Phase (45 Hz - 850 Hz) (Typical for 10 Hz to 45 Hz and 850 Hz to 1 MHz) |
0.025 ± [ 0.005 * V range / V reading )] ± (0.1 / V range ) ± ( 0.002 *F ) |
| Current Harmonics (45 Hz - 850 Hz) (Typical for 10 Hz to 45 Hz and 850 Hz to 1 MHz) |
± 0.08% of Reading ± 0.08% of Range ± (0.02*F)% of Reading ± (20 μV /Z ext ) |
| Current Harmonics Phase (45 Hz - 850 Hz) (Typical for 10 Hz to 45 Hz and 850 Hz to 1 MHz) |
0.025 ± [0.005 * A range / A reading )] ± (0.001 / A range * Z ext )) ± (0.002 *F) |
| Physical characteristics |
| Dimensions |
| Height |
13.2 cm. or 5.2 in. |
| Width |
42 cm. or 16.5 in. |
| Depth |
31 cm. or 12.5 in. |
| Weight |
| Net (without lead set) |
8.8 kg or 19.5 lb. |
| Temperature |
| Storage |
-20 °C to +60 °C |
| Operating |
0 °C to +40 °C |